Allegro Industries 9846 user manual

User manual for the device Allegro Industries 9846

Device: Allegro Industries 9846
Category: Oxygen Equipment
Manufacturer: Allegro Industries
Size: 0.25 MB
Added : 5/6/2013
Number of pages: 13
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Allegro Industries 9846. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Allegro Industries 9846.

For your convenience

If looking through the Allegro Industries 9846 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Allegro Industries 9846 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Allegro Industries 9846 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Allegro Industries 9846 User manual - Online PDF
Advertisement
« Page 1 of 13 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Allegro Industries 9846 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Allegro Industries 9846. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

USER'S MANUAL



AMBIENT AIR BREATHING
APPARATUS (AABA) PUMPS

P/N 9806
P/N 9821
P/N 9832
P/N 9833
P/N 9846
P/N 9850













Read and understand all instructions before using this product.

Open carton carefully and inspect product for damage caused by carrier.
If any damage is found, report and submit claim to carrier.





®
ALLEGRO
INDUSTRIES
P/N: UM006

Summary of the content on the page No. 2

TABLE OF CONTENTS PAGE NUMBER INTRODUCTION/DESCRIPTION .....................................................................................................................1 WARNINGS AND LIMITATIONS......................................................................................................................1 SAFETY PRECAUTIONS ...................................................................................................................................2 USERS INS

Summary of the content on the page No. 3

INTRODUCTION This manual provides instructions for the use and maintenance of Allegro Ambient Air Breathing Apparatus (AABA) Pumps. You must read and understand this manual and be trained in the proper use of the equipment before using it in a contaminated atmosphere. There are many federal, state, and local codes and regulations governing sales, construction, installation, and/or use of products for certain purposes, which may vary. Allegro cannot be held responsible for how the

Summary of the content on the page No. 4

S A F E T Y P R E C A U T I O N S FOLLOW ALL WARNINGS AND CAUTIONS ALL PUMPS: DO NOT place oil-less air pump in an area that cannot GUARANTEE clean Grade D breathable air, per OSHA 29 CFR 1910.134 to the AABA inlet. See below for Grade D requirements. DO NOT attempt to service the air pump while it is running or while it is connected to electrical or air power. DO NOT oil or lubricate the pump. DO NOT kink power cord and never allow the cord to come in contact with oil, grease, hot

Summary of the content on the page No. 5

U S E R ’ S I N S T R U C T I O N S 1) Ensure that the pump (or inlet extension filter) is in a clean uncontaminated air environment. o If clean air CANNOT be guaranteed at the pump inlet at all times, use the Inlet extension hose kit (P/N: 9700-65). See instructions on the Inlet extension kit below. 2) Ensure canister on the discharge filter assembly is firmly seated and secure before startup. o Discharge air passes through the HEPA outlet filter located inside the discharged filte

Summary of the content on the page No. 6

T O L E R A N C E S A N D W A R N I N G S Allegro ambient air pumps are precision pumps that have only .0015-.003 clearance between the top of the rotor and cylinder bore, and .003 or less clearance between end of the rotor and the end plate. Any thrust on the shaft such as mishandling or dropping the pump on its end will tend to close these clearances, causing the rotor to jam. Foreign particles, excessive dirt or dust build up may cause sluggish performance and eventual “jamming” of

Summary of the content on the page No. 7

S P E C I F I C A T I O N S The table shows the maximum allowable number of tight-fitting respirators or loose-fitting hoods. MODEL PART MAX NO. MAX NO. POWER NUMBER NO. RESP. HOODS REQUIRED LBS HP PSI CFM A-300 9806 1 0 5.5A 115/230V 30 ¼ 0 – 15 0 – 5 A-750 9821 2 1 8.3A 115/230V 53 ¾ 0 – 15 0 – 10 A-1500TE 9832 3 2 16A 115/230V 97 1 ½ 0 – 15 0 – 20 A-1500EX 9833* 3 2 10.6A 115/230V 122 1 ½ 0 – 15 0 – 15 A-3000ATE 9846 6 4 30A 115/230V 203 3 0 – 15 0 – 32 A-400

Summary of the content on the page No. 8

M A I N T E N A N C E FILTERS: • Change inlet filter every 200 running hours or if the pressure gauge shows a drop in pressure. • Change discharge filter every 200 running hours or if the pressure gauge shows an increase in pressure. FLUSHING INSTRUCTIONS: 1. Perform this procedure in a well ventilated area. 2. Wear solvent resistant gloves and eye protection while performing the flushing procedure. 3. Disconnect airline hose and respirator to prevent contamination. 4. Remove inlet f

Summary of the content on the page No. 9

P A R T S & A C C E S S O R I E S All Models • 9700-02 Exhaust filter element (Each) • 9700-11 Pump flushing liquid • 9700-15 Exhaust filter canister (Canister only) • 9700-65 Universal inlet hose kit (50 Feet) • 9700-68 ⅜” Coupler, locking Hansen • 9700-69 ⅜” Coupler, Hansen • 9700-71 ¼” Coupler, Schrader • 9700-72 ½” Coupler, Hansen • 9700-73 ¼” Coupler, OBAC • 9700-74A ¼” Coupler, Hansen Model A-300 • 9700-04 Pressure gauge • 9700-07 Inlet fi

Summary of the content on the page No. 10

T R O U B L E S H O O T I N G ELECTRIC MODELS: 1) If motor fails: • If motor is extremely cold. o Bring to room temperature before starting. • Ensure respirator and hose are connected when pump is running; failure to do so may cause lock-up. o Loosen all six pump endplate bolts slightly. Re-tighten and try to run unit. • Some motors are thermally protected. An electrical overload or mechanical failure may cause a thermally protected motor to stop running. o Let motor cool down (

Summary of the content on the page No. 11

4) If there is a drop in outlet pressure: • Check if exhaust filter housing and canister is cross-threaded or not seated firmly onto housing gasket. o Remove canister, inspect threads and gasket and reinstall. • Check for dirty inlet filter element. o Replace if necessary. • Check if vanes are sticking or worn out. o Flush pump with approved solvent. o If unsuccessful, follow instructions under Disassembly, to check vane condition. o Replace if necessary. • Check adjustment of press

Summary of the content on the page No. 12

WARRANTY Damage resulting from carrier handling abuse is not covered by product warranty. To protect your interest, inspect product immediately. The following warranty information is made in lieu of all other warranties expressed, implied or statutory, including but not limited to, the implied warranties of merchantability and fitness for purpose. It is in lieu of any implied warranty of merchantability, fitness for a particular purpose or other warranty of quality, except of title and

Summary of the content on the page No. 13

ambairpumman.doc Rev C. 07/03 11


Alternative user manuals
# User manual Category Download
1 Allegro Industries 9821 User manual Oxygen Equipment 4
2 Allegro Industries 9833 User manual Oxygen Equipment 0
3 Allegro Industries 9832 User manual Oxygen Equipment 2
4 Allegro Industries 9850 User manual Oxygen Equipment 0
5 Allegro Industries 9806 User manual Oxygen Equipment 0
6 3M 8110S User manual Oxygen Equipment 1
7 3M 7187 User manual Oxygen Equipment 1
8 3M 8210PLUS User manual Oxygen Equipment 1
9 3M 8214 User manual Oxygen Equipment 0
10 3M 8210 User manual Oxygen Equipment 6
11 3M 8211 User manual Oxygen Equipment 1
12 3M 8511 User manual Oxygen Equipment 2
13 3M 6000 User manual Oxygen Equipment 20
14 3M RESPIRATOR N95 PARTICULATE 8511 User manual Oxygen Equipment 1
15 3M 10008 User manual Oxygen Equipment 0