Mitsubishi Electronics SKM25ZD-S user manual

User manual for the device Mitsubishi Electronics SKM25ZD-S

Device: Mitsubishi Electronics SKM25ZD-S
Category: Air Conditioner
Manufacturer: Mitsubishi Electronics
Size: 2.69 MB
Added : 7/9/2013
Number of pages: 42
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Mitsubishi Electronics SKM25ZD-S. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Mitsubishi Electronics SKM25ZD-S.

For your convenience

If looking through the Mitsubishi Electronics SKM25ZD-S user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Mitsubishi Electronics SKM25ZD-S on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Mitsubishi Electronics SKM25ZD-S to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Mitsubishi Electronics SKM25ZD-S User manual - Online PDF
Advertisement
« Page 1 of 42 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Mitsubishi Electronics SKM25ZD-S but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Mitsubishi Electronics SKM25ZD-S. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

USER’S MANUAL
MITSUBISHI DAIYA
ENGLISH
ROOM AIR CONDITIONER
FRANÇAIS
MANUEL DE L’UTILISATEUR
CLIMATISEUR D’INTERIEUR
DEUTSCH
ANWENDERHANDBUCH
¨
BETRIEBSEINHEIT KLIMAGERAT
SKM22ZD-S
ITALIANO
ISTRUZIONI PER L’USO
SKM25ZD-S
SKM28ZD-S
CONDIZIONATORE D’ARIA COMPATTO
SKM35ZD-S
˜
SKM50ZD-S
ESPANOL
MANUAL DEL PROPIETARIO
ACONDICIONADOR AMBIENTAL DE AIRE INCORPORADO
NEDERLANDS
GEBRUIKERSHANDLEIDING
KAMER-AIR-CONDITIONING
PORTUGUÊS
MANUAL DO UTILIZADOR
APARELHO DE AR CONDICIONADO DE INTERIOR
∂§§∏¡π∫∞
√¢∏°

Summary of the content on the page No. 2

Thank you for purchasing a Mitsubishi Daiya Air Conditioner. To get the best long-lasting performance, read and follow this User’s Manual carefully before using your air condi- tioner. After reading, please store the Manual in a safe place and refer to it for operational questions or in the event of any irregularities. This air conditioner is intended for domestic use. A new refrigerant (R410A) is used in this air-conditioner. When asking the dealer for service or inspection and maintenance, exp

Summary of the content on the page No. 3

Safety precautions • Before starting to use the system, please read these “Safety precautions” carefully to ensure proper operation of the system. • The safety precautions are classified as “ DANGER” and “ CAUTION”. Precautions as shown in the column “ DANGER” indicate that improper handling could have dramatic consequences like death, serious injury, etc. Nevertheless, even precautions as shown in the column “ CAUTION” might pose a serious problem, depending on the circumstances. Please obs

Summary of the content on the page No. 4

Safety precautions CAUTION Do not handle the switches with wet Don’t swing from the system. Only use approved fuses. hands. Use of steel or copper wire instead of an approved This may cause an electric shock. If the system falls down, fuse is strictly forbidden, as it may cause a breakdown you may get injured. or fire. Do not place a combustible insecticide You should not expose any combus- Do not wash the air conditioner with wa- or paint spray near the blower, nor aim it tion appliance directl

Summary of the content on the page No. 5

Choice of operations and features Choise of operations Page 9 Page 9 HEAT COOL The unit draws in heat from the outside air, transfers it inside and Cooling by extracting heat from the room. heats the room. Page 9 Page 8 DRY AUTO Automatic selection of operating mode. Drying by extracting damp from the room. The Auto mode automati- cally selects the operation mode (HEAT, COOL or Functioning of micro-computer depends on setting and room tem- DRY), depending on the peratures. It dehumidif

Summary of the content on the page No. 6

Name of each part and its function INDOOR UNIT SKM22ZD-S SKM35ZD-S SKM25ZD-S SKM50ZD-S SKM28ZD-S Air inlet grille Draws in the indoor air. Air filter Removes dust or dirt from the inlet air. Page 15 Natural enzyme filter Photocatalytic washable deodorizing filter Room temperature detector Unit operation section Unit indication section and remote control signal receiver Air outlet Air blows out of here. Left/right air flow adjustment fin Page 10 Drain hose Drains water from the dehumidified air

Summary of the content on the page No. 7

Unit indication section RUN (HOT KEEP) light (green) • Illuminates during operation. • Blinks at air flow stop due to the ‘HOT KEEP’. Page 17 TIMER light (yellow) Illuminates during TIMER operation. HI POWER light (green) Illuminates during HI POWER operation. ECONOMY light (orange) Illuminates during ECONOMY operation. How to open the suction grill Place fingers at the recesses on both sides of the grill and pull up the grill to this side so that it will be opened by about 60 degrees. How to

Summary of the content on the page No. 8

Operation and indication section for remote control Operation section FAN SPEED button OPERATION MODE select button Each time the button is pushed, the indi- Each time the button is pushed, the indi- cator is switched over in turn. cator is switched over in turn. HI POWER ECONO AUTO AM PM HI ON/OFF button HI POWER button MED Press for starting operation, press again for LO This button changes the HI POWER mode. ON OFF stopping. Page 9 ON OFF FAN SPEED MODE ECONOMY button This button changes the

Summary of the content on the page No. 9

AUTO mode operation procedure  Automatically selects the operation mode (HEAT, DRY, COOL) depending on the room temperature when switched on. Aim the remote control at the air conditioner. Press the ON/OFF button. 1 HI POWER ECONO When the unit is not in AUTO mode: AUTO AM HI MED Press MODE button. LO 2 Move the [ mark] to the (Auto) position. ON OFF FAN SPEED MODE HI POWER TEMP ECONO To stop: Press the ON/OFF button. AIR FLOW TIME CANCEL NOTE AUTO mode can be operated by simply ON OFF RESERVE

Summary of the content on the page No. 10

COOL/HEAT/DRY mode operation procedure Aim the remote control at the air conditioner. Press the ON/OFF button. 1 HI POWER ECONO AUTO AM Press the MODE select button. HI 2 MED Move the [ mark] to the desirable operation position. LO (Cool), (Heat), (Dry) ON OFF FAN SPEED MODE HI POWER TEMP ECONO Press the TEMP button. 3 Press or button for the desired temperature. AIR FLOW Standard 26°C~28°C2 22°C~24°C1°C~24°C TIME CANCEL ON OFF RESERVE TIMER TIME ACL Press the FAN SPEED button 4 Set the air fl

Summary of the content on the page No. 11

Air flow direction adjustment procedure Adjusting up/down air flow direction  Up/down direction can be adjusted with the AIRFLOW button on the remote control. Each time when you press this button the mode changes as follows: (Air scroll) (SWING) (flap stopped) Change to AIRFLOW mode. Air scroll SWING FLAP In COOL and DRY operation In HEAT operation Stops at this position Stops at this position for 5 seconds. for 5 seconds. Flap moves up and down continuously. Thick line : moves quickly Thick li

Summary of the content on the page No. 12

Present time setting procedure  When inserting the batteries, the present time is automatically set to PM 1:00. Example: Set to AM 10:30. Press the TIME switch. 1 Press with the tip of a ball pen, etc. HI POWER ECONO The time indicator blanks and can be set to the current time. AUTO AM HI MED LO Press the “ or ” button. 2 ON OFF FAN SPEED MODE (Set to AM 10:30) HI POWER TEMP ECONO Press within AIR FLOW 15 sec.! Press the RESERVE button. 3 TIME CANCEL The indication changes from blinking to stea

Summary of the content on the page No. 13

ON-TIMER operation procedure  If the room temperature is at near optimum temperature at the set time, the operation starts 5 to 60 minutes before the set time. Page 13 Example: In the case you wish to bring the temperature to nearly set temperature in at AM 8:00. Press the ON TIMER button. 1 HI POWER ECONO ON TIMER indicator is blinking. AUTO ON AM HI MED LO ON Press the “ or ” button. 2 ON OFF FAN SPEED MODE Each time the button is pressed, the indicator is switched in the order of: AM AM AM

Summary of the content on the page No. 14

 About TIMER operation About Amenity facilities Amenity facilities enable to start the operation a little earlier, so that the room approaches optimum temperature at ON time when the operation is started by ON-TIMER. • Mechanism The room temperature is checked In COOL operation 60 minutes before the timer is at ON. Depending on the tempera- (Stop) Operation starts ture at that time, the operation starts 5 to 60 minutes before the (Operation) timer is at ON. Set temperature • The Amenity facili

Summary of the content on the page No. 15

Warning note for remote control handling • Don’t go near high temperature • Don’t leave the remote control ex- • Don’t drop the remote control. places, such as an electric carpet posed to direct sunlight or other Handle with care. or stove. strong lighting. • Don’t put any obstructing obsta- • Don’t spill water etc on the remote • Do not place heavy objects on the cles between the remote control control. remote controller, or step on it. and the unit. When the operation fails with the remote con

Summary of the content on the page No. 16

Maintenance Before maintenance During the operational season Cleaning the air filter Standard interval is once every two week Turn off the power switch. Remove the air filter 1 1 Pull up to this side the suction grill. 2 Lightly hold the knobs at both sides and lift a little to remove the grill to this side. Don’t spill water. Cleaning There's a danger 2 of electric shock. If the filter is very dirty, clean it with warm water (approx. 30°C), and dry it thoroughly. CAUTION • Don’t clean the filte

Summary of the content on the page No. 17

Installing, inspecting, and replacing the natural enzyme filter and the photocatalytic washable deodorizing filter • Installing the natural enzyme filter and the photocatalytic washable deodorizing filter Filter holder 1. Open the air inlet grill and remove the air filters. 2. Install the filter holders, with the natural enzyme filter and the photocatalytic washable deo- dorizing filter installed in the holders, in the air conditioner. 3. Install the air filters and close the air inlet grill.

Summary of the content on the page No. 18

About the Multiple Air-conditioner Simultaneous Operation • The air-conditioners cannot be in different operating modes at the same time, such as one unit being in the “Cool” mode and one unit being in the “Heat” mode. • When conducting different operations, the air conditioner that was operated first will be given priority, so the air conditioner that is operated after that will conduct air blowing operation. • When you want to give priority to the air conditioner that was started later, eit

Summary of the content on the page No. 19

Please remember! You cannot restart the unit immediately after you have Restarting has been blocked for 3 minutes after you have stopped or stopped it. after switching off the power during operation, to protect the unit. (RUN light is on) Not Please wait for operating? three minutes. The three-minute protection timer in the microcomputer automatically starts up again. Air is not blown out when starting the HEATING operation. Air flow has stopped to prevent blowing out of cold air until the indoo

Summary of the content on the page No. 20

When to contact your distributor without delay Turn off the power switch immediately and inform your dealer in any of the following situations: The fuse or switch blows continu- The cable becomes extremely hot. ously. The covering of the cable is cracked. CAUTION Fuse often blows. If the power cord becomes damaged, ask your dealer or a qualified engineer to install the replacement to avoid accidents. The TV, radio or other equipment A switch does not activate properly. You hear a strange noise d


Alternative user manuals
# User manual Category Download
1 Mitsubishi Electronics 15 User manual Air Conditioner 120
2 Mitsubishi Electronics 20-L User manual Air Conditioner 11
3 Mitsubishi Electronics 2.5KKC User manual Air Conditioner 14
4 Mitsubishi Electronics 20-MYA User manual Air Conditioner 16
5 Mitsubishi Electronics 8 User manual Air Conditioner 3
6 Mitsubishi Electronics A18AR User manual Air Conditioner 4
7 Mitsubishi Electronics CITY MULTI PKFY-PVAM-A User manual Air Conditioner 43
8 Mitsubishi Electronics CMB-P-V-F User manual Air Conditioner 12
9 Mitsubishi Electronics CITY MULTI PUHY-YMC User manual Air Conditioner 227
10 Mitsubishi Electronics A12 User manual Air Conditioner 27
11 Mitsubishi Electronics LOSSNAY LGH-100RX4-E User manual Air Conditioner 45
12 Mitsubishi Electronics LOSSNAY LGH-150RX4-E User manual Air Conditioner 18
13 Mitsubishi Electronics G-50A User manual Air Conditioner 458
14 Mitsubishi Electronics 20 PRH-5 User manual Air Conditioner 7
15 Mitsubishi Electronics LOSSNAY LGH-200RX4-E User manual Air Conditioner 16
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21