Univex IT Series user manual

User manual for the device Univex IT Series

Device: Univex IT Series
Category: Carbon Monoxide Alarm
Manufacturer: Univex
Size: 1.48 MB
Added : 11/8/2014
Number of pages: 41
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Univex IT Series. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Univex IT Series.

For your convenience

If looking through the Univex IT Series user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Univex IT Series on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Univex IT Series to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Univex IT Series User manual - Online PDF
Advertisement
« Page 1 of 41 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Univex IT Series but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Univex IT Series. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MODEL 5100-02-IT
IT Series
COMBUSTIBLE GAS SENSOR MODULE
Version 2.00a


APPLICABILITY & EFFECTIVITY
Effective for all Model 5100-02-IT Modules manufactured after February 15, 2008.
Instruction Manual Part Number T12019
Rev. B1

Summary of the content on the page No. 2

Model 5100-02-IT Combustible Gas Sensor Module FM APPROVAL ONLY THE FOLLOWING ITEMS, FUNCTIONS AND OPTIONS ARE FM* APPROVED Model 5100-02-IT Combustible Gas Sensor Module Sensor Module Model 5100-02-IT Combustible Gas Sensor Module Model 5100-02-IT-SS Combustible Gas Sensor Module, 316SS Calibration Equipment Model 1200-26 Calibration Gas Delivery System Model 1290-02 Combustible Gas Cylinder Model 5358-01 Calibration Head, Standard Model 5360-00 Calibration Gas Deli

Summary of the content on the page No. 3

Model 5100-02-IT Combustible Gas Sensor Module TABLE OF CONTENTS 1. PRODUCT DESCRIPTION .............................................................................................................................3 1.1 GENERAL........................................................................................................................................................3 1.2 PRODUCT CONFIGURATION........................................................................................

Summary of the content on the page No. 4

Model 5100-02-IT Combustible Gas Sensor Module 6.2 ENCLOSURE REPLACEMENT ....................................................................................................................23 6.3 TRANSMITTER REPLACEMENT .................................................................................................................24 6.4 SENSOR REPLACEMENT............................................................................................................................24 6.5 INSTALL

Summary of the content on the page No. 5

Model 5100-02-IT Combustible Gas Sensor Module 1. PRODUCT DESCRIPTION 1.1 GENERAL The Model 5100-02-IT Catalytic Bead Combustible Gas Sensor Module is a member of the Sentry Information Technology ”IT” family of gas sensor transmitter modules. IT modules offer a broad array of features including: • Integral Alphanumeric display • 180 day calibration frequency • Integral alarm relays (3) • 4-20 mA output ® • Modbus RTU interface • SMC Sentry interface • 316 Stainless steel enclosur

Summary of the content on the page No. 6

Model 5100-02-IT Combustible Gas Sensor Module Figure 1-1 Model 5100-02-IT Combustible Gas Sensor Module Stainless Steel – Dimensions Figure 1-2 Model 5100-02-IT Combustible Gas Sensor Module Aluminum – Dimensions Page: 4

Summary of the content on the page No. 7

Model 5100-02-IT Combustible Gas Sensor Module 1.4.2 MODBUS OPERATION All IT gas sensor modules have a Modbus RTU RS-485 serial interface to allow direct connection to any standard PLC or DCS. The Module Address Switch (section 3.5) allows the user to select Modbus addresses 1 thru 15. Switch position “0” allows the user to set addresses up to 254 using the s Menu (See Table 4-3). Figure 3-4 provides the wiring terminations for Modbus connections. 1.4.3 ANALOG OPERATION All IT gas s

Summary of the content on the page No. 8

Model 5100-02-IT Combustible Gas Sensor Module 1.6 INTERCONNECT WIRING Not supplied with the sensor module, but necessary to the installation and operation is the multi conductor wiring which connects the module to its power source and controller. Before this wiring is installed it is important to read and understand the control system installation instructions to determine wiring requirements and alternatives. 1.7 POWER REQUIREMENTS IT modules operate on DC power between 10 VDC and 30

Summary of the content on the page No. 9

Model 5100-02-IT Combustible Gas Sensor Module 2. CAUTIONS & WARNINGS 2.1 INTRODUCTION Although IT Transmitter Modules are designed and constructed for installation and operation in industrial applications including "hostile" environments, caution should be taken to insure that the installation is made in compliance with this instruction manual and that certain procedures and conditions are avoided. This chapter discusses the necessary cautions. Read the entire chapter prior to installat

Summary of the content on the page No. 10

Model 5100-02-IT Combustible Gas Sensor Module 2.3.1 CATALYTIC BEAD SENSOR MODULES Model 5100-02-IT Gas Sensor Modules are FM performance approved for detection of Combustible gas (methane and hydrogen). The sensor is cross sensitive to the combustible gases indicated in Table 2-1. Risk management planning should take into consideration the potential for the presence of other gases in the monitored area. Note that the 5100-02-IT has a gas factor scaling feature in which a calibration sta

Summary of the content on the page No. 11

Model 5100-02-IT Combustible Gas Sensor Module 3. INSTALLATION NOTE All IT modules are factory pre-configured and calibrated. All modules are tagged to indicate the configuration including the sensor module number. Identify all components during unpacking and install using the factory configuration. 3.1 SENSOR MODULE LOCATIONS Select locations for each sensor module based on the following: • Modules should be placed close to the potential source of gas. • Modules should be placed in ar

Summary of the content on the page No. 12

Model 5100-02-IT Combustible Gas Sensor Module 3.3 ENCLOSURE INSTALLATION To protect the transmitter and sensor assembly they should be removed from the enclosure and preserved until final installation and wiring termination. Prior to installation and wiring. 1. Remove the transmitter from the module housing by: • Unscrew the two captive panel screws on the face plate. • Lift the transmitter out of the housing. • Unplug the sensor cable from transmitter connector J2. • Remove the senso

Summary of the content on the page No. 13

Model 5100-02-IT Combustible Gas Sensor Module 6. Carefully return the transmitter to the enclosure installing it over the two standoffs. Tighten the retaining screws into the standoffs. P1 FUNCTION P2 FUNCTION 1 High Alarm Relay NC 1 Power 2 High Alarm Relay NO 2 Signal 3 High Alarm Relay COM 3 Ground 4 Low Alarm Relay NC 4 N/A 5 Low Alarm Relay NO 5 N/A 6 Low Alarm Relay COM 6 4-20 mA output - 7 Trouble Relay NC* 7 4-20 mA output + 8 Trouble Relay NO* 8 RS-485 Ground 9 Trouble Rel

Summary of the content on the page No. 14

Model 5100-02-IT Combustible Gas Sensor Module 3.5 INSTALLATION CONFIGURATION Table 3-3 and Figures 3-1 through 3-4 provide location and installation details. POSITION ADDRESS POSITION ADDRESS 1 Sensor 1 9 Sensor 09 2 Sensor 2 A Sensor 10 3 Sensor 3 B Sensor 11 4 Sensor 4 C Sensor 12 5 Sensor 5 D Sensor 13 6 Sensor 6 E Sensor 14 7 Sensor 7 F Sensor 15 8 Sensor 8 0 Select Table 3-2 Sensor Module Rotary Switch Positions Figure 3-1 Module Address Rotary Switch NOTE For Sentry applicati

Summary of the content on the page No. 15

Model 5100-02-IT Combustible Gas Sensor Module Figure 3-3 4-20 mA Connection Page: 13

Summary of the content on the page No. 16

Model 5100-02-IT Combustible Gas Sensor Module Figure 3-4 Digital Interface Connections Figure 3-5 Remote Alarm Reset Page: 14

Summary of the content on the page No. 17

Model 5100-02-IT Combustible Gas Sensor Module 4. INTRODUCTION – HUMAN-MACHINE INTERFACE SYSTEM The Combustible Gas Sensor utilizes a visual menu system operated by means of a magnet. A magnet stick is supplied for this purpose. The menu system is used to configure alarm set-points, calibrate the sensor module, and for maintenance procedures and alarms acknowledge. 4.1 HUMAN-MACHINE INTERFACE The module menu system is operated by means of directing the magnet stick toward each of four i

Summary of the content on the page No. 18

Model 5100-02-IT Combustible Gas Sensor Module 4.2 MAIN MENU Table 4-1 describes the primary human-machine interface operation. Key Function Display Description Reference M E Mode Switch [M] M E Enter Switch [E] ME Up Switch [ ▲] Previous Menu ME Down Switch [ ▼] Next Menu 5100-02 First screen at power up-model 1.Xxa VX.Xxx Second screen at power up-version Warm.XXX Third screen at start up-warm up 0%LEL Normal condition - default display M E Mode ALMRSET: Mode Function -Alarms Acknowledg

Summary of the content on the page No. 19

Model 5100-02-IT Combustible Gas Sensor Module 4.3 CONFIGURE SET-POINTS The sensor module set-points menu is used to initially set-up the alarm set points, relay actions, gas type and range, 4-20 mA action and RS-485/Sentry address and baud rates (See Menu Key in Appendix J). • Alarm Set-points: Once the Set-up menu is selected, press [E] to activate the Alarm Set-point screen. Use the [ ▲] or [ ▼] keys to select Low Alarm or High Alarm menu. Key [ ▲] will adjust the setpoint upwards a

Summary of the content on the page No. 20

Model 5100-02-IT Combustible Gas Sensor Module Key Function Display Description Reference --0%LEL- Default Display M E Mode ALMRSET: Mode Function - Alarm Reset M E Mode CALIB:-- Mode Function - Calibrate M E Mode SETUP:--- Mode Function - Set Point Adjustments M E Enter Alarms S.P. Function - Alarm Adjust * A Below ME Down Relays S.P. Function - Relays Adjust * B Below ME Down GasFactr S.P. Function - Gas Factor Adjust * C pg. 19 ME Down 4-20mA S.P. Function - 4-20 mA Adjust * D pg. 19 M


Alternative user manuals
# User manual Category Download
1 Univex 5100-02-IT User manual Carbon Monoxide Alarm 4
2 3M MACURCO GD-2 User manual Carbon Monoxide Alarm 20
3 Airflow Systems IAQ10 User manual Carbon Monoxide Alarm 1
4 Aico Ei261DENRC User manual Carbon Monoxide Alarm 1
5 Advantech PCI-1718 Series User manual Carbon Monoxide Alarm 1
6 3M MACURCO GD-6 User manual Carbon Monoxide Alarm 55
7 Aico Ei261ENRC User manual Carbon Monoxide Alarm 14
8 Airflow Systems IAQ50 User manual Carbon Monoxide Alarm 10
9 American Sensor CO900 User manual Carbon Monoxide Alarm 0
10 American Sensor CO910 User manual Carbon Monoxide Alarm 1
11 American Sensor CO920 User manual Carbon Monoxide Alarm 1
12 Bacharach 2800 User manual Carbon Monoxide Alarm 0
13 Bacharach DIOXOR 19-7043 User manual Carbon Monoxide Alarm 0
14 Bacharach 3015-4286 User manual Carbon Monoxide Alarm 1
15 Bacharach Fyrite Insight Residential Combustion Analyzer User manual Carbon Monoxide Alarm 5