Universal CD-9775 user manual

User manual for the device Universal CD-9775

Device: Universal CD-9775
Category: Carbon Monoxide Alarm
Manufacturer: Universal
Size: 0.06 MB
Added : 11/8/2014
Number of pages: 9
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Universal CD-9775. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Universal CD-9775.

For your convenience

If looking through the Universal CD-9775 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Universal CD-9775 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Universal CD-9775 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Universal CD-9775 User manual - Online PDF
Advertisement
« Page 1 of 9 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Universal CD-9775 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Universal CD-9775. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MODEL CD-9775
SMOKE & CARBON MONOXIDE ALARM
WITH SILENCE CONTROL
E
READ ALL INSTRUCTIONS
The smoke alarm uses an extremely small amount of a radioactive element in the ionization
chamber. Do not tamper with radioactive sealed source or try to repair the smoke alarm
yourself. Refer to instructions for repairs.
LIMITATIONS AND FUNCTIONS
• This combination smoke/carbon monoxide (CO) alarm requires constant 120VAC power to
operate properly.
• THERE ARE TWO BASIC SMOKE ALARM TYPES - IONIZATION AND P

Summary of the content on the page No. 2

IMPORTANT SAFETY INFORMATION About this Alarm This combination alarm has separate sensors to detect smoke and carbon monoxide (CO). The smoke alarm has priority over the CO alarm. The combination smoke/CO alarm is designed to be used in ordinary indoor locations of single-family households only. The sensitivity of both the smoke and CO sensors and the horn patterns for both warnings, comply with UL standards. This combination smoke/CO alarm can be used as a replacement for all UNIVERSAL Smoke an

Summary of the content on the page No. 3

WHAT YOU SHOULD DO IF THE SMOKE ALARM SOUNDS YOU MUST QUICKLY DO THE FOLLOWING: If the smoke alarm sounds and you have not pushed the test button, it is a warning of a dangerous situation. Your immediate response is necessary. To prepare for such occurrences, develop family escape plans, discuss them with ALL household members and practice them regularly. BASICS OF ESCAPE PLAN o Make a floor plan indicating all doors and windows and at least two escape routes from each room. Second story windows

Summary of the content on the page No. 4

INSTALLING THE COMBINATION SMOKE/CO ALARM FOR RESIDENTIAL USE LOCATION Before installing your combination smoke/CO alarm, it is important to choose the best locations in your home. Placement can affect how well the alarm performs and how well residents hear the alarm if it sounds. Statistics of the National Fire Protection Association (NFPA) show that most of the fatal CO occurrences happen at night while people are sleeping. Early warning of CO is best achieved by the installation of CO alarms

Summary of the content on the page No. 5

Existing Homes: The NFPA requires a smoke alarm on every level and outside each sleeping area in existing construction. An existing household with one level and one sleeping area is required to have one smoke alarm. New Construction Homes and Manufactured Homes: The NFPA requires AC-powered, interconnected smoke alarms to be installed inside each bedroom, outside each bedroom area, and on every level of the home. They also require a minimum of two AC-powered, interconnected smoke alarms in any n

Summary of the content on the page No. 6

THIS COMBINATION SMOKE/CO ALARM WILL NOT WORK WITHOUT A GOOD BATTERY PROPERLY INSTALLED. THE ALARM SHOULD BE TESTED WHEN INSTALLED AND THEN TESTED WEEKLY AFTER THAT. INSTALLATION AND OPERATION INSTALLATION INSTRUCTIONS: CAUTION!! READ CAREFULLY. CAUTION: THIS UNIT IS SEALED. THE COVER IS NOT REMOVABLE! • This combination smoke/CO alarm requires a working 9 Volt battery to operate properly. This combination smoke/CO alarm WILL NOT work if the battery is removed, drained or improperly connected. D

Summary of the content on the page No. 7

STANDBY (NON-ALARM) CONDITION: Whenever battery power is present, the Green LED is off and flashes on approximately every 40 seconds and the Red LED is off. (ALARM) CONDITION: For BOTH the SMOKE and CO alarm conditions, the Red LED flashes on and the unit emits a loud, pulsating alarm (refer to the OPERATION section to differentiate between the SMOKE and CO alarm patterns). RESETTING YOUR ALARM: Reset your alarm by momentarily pushing the "TEST/SILENCE" button. END-OF-SERVICE LIFE CONDITION:

Summary of the content on the page No. 8

BACKUP BATTERY REPLACEMENT This alarm uses a 9 Volt Alkaline battery. The battery should last for at least one year under normal operating conditions. The alarm has a low battery indicator, an audible "beep." It will operate at 30- 40 second intervals for a minimum of 7 days. When this indication occurs, replace the battery with an Alkaline type (Eveready Energizer #522, Duracell #MN1604), or Lithium type (ULTRALIFE U9VL- TM J), from your local retailer. Use the convenient QUICK DRAW pull-out b

Summary of the content on the page No. 9

UNIVERSAL FIVE YEAR LIMITED WARRANTY UNIVERSAL SECURITY INSTRUMENTS, INC. ("USI") warrants your USI product to be free from defects in material and workmanship for a period of five (5) years from the date of purchase. This warranty applies only to the original consumer purchaser and only to products used in normal residential use and service. If this product is found to be defective, USI's only obligation, and your exclusive remedy, is the repair or replacement of the product, at USI's discreti


Alternative user manuals
# User manual Category Download
1 Universal CD-9775 User manual Carbon monoxide (CO) detectors 0
2 3M MACURCO GD-2 User manual Carbon Monoxide Alarm 20
3 Airflow Systems IAQ10 User manual Carbon Monoxide Alarm 1
4 Aico Ei261DENRC User manual Carbon Monoxide Alarm 1
5 Advantech PCI-1718 Series User manual Carbon Monoxide Alarm 1
6 3M MACURCO GD-6 User manual Carbon Monoxide Alarm 55
7 Aico Ei261ENRC User manual Carbon Monoxide Alarm 14
8 Airflow Systems IAQ50 User manual Carbon Monoxide Alarm 10
9 American Sensor CO900 User manual Carbon Monoxide Alarm 0
10 American Sensor CO910 User manual Carbon Monoxide Alarm 1
11 American Sensor CO920 User manual Carbon Monoxide Alarm 1
12 Bacharach 2800 User manual Carbon Monoxide Alarm 0
13 Bacharach DIOXOR 19-7043 User manual Carbon Monoxide Alarm 0
14 Bacharach 3015-4286 User manual Carbon Monoxide Alarm 1
15 Bacharach Fyrite Insight Residential Combustion Analyzer User manual Carbon Monoxide Alarm 5