Firex SERIES 10000 user manual

User manual for the device Firex SERIES 10000

Device: Firex SERIES 10000
Category: Carbon Monoxide Alarm
Manufacturer: Firex
Size: 0.22 MB
Added : 7/9/2013
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Firex SERIES 10000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Firex SERIES 10000.

For your convenience

If looking through the Firex SERIES 10000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Firex SERIES 10000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Firex SERIES 10000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Firex SERIES 10000 User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Firex SERIES 10000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Firex SERIES 10000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

110-1125C Eng 2/22/06 11:32 AM Page 1
©2006 INVENSYS CONTROLS AMERICAS
Carbon Monoxide Alarm
110-1125C
SERIES 10000
MODEL COE: 120 V AC/DC CARBON MONOXIDE ALARM
WITH BATTERY BACKUP
SERIES 10200
MODEL COE-B: DC ONLY CARBON MONOXIDE ALARM
SERIES 10400
MODEL COEA: 120 V AC CARBON MONOXIDE ALARM
PLEASE READ AND SAVE THIS ENTIRE MANUAL
Installer: Please leave this manual with the product
Electrical rating:
120V AC, 60Hz, 0.05amp
Single or multiple station CO alarm
Model COE includes 9V battery bac

Summary of the content on the page No. 2

110-1125C Eng 2/22/06 11:32 AM Page 2 NOTE: AC/DC alarms offer added protection in the event of a power failure or a drained battery. • DO NOT remove or disconnect the battery or turn off AC power to quiet unwanted alarms. This will remove your protection. This alarm features a Quick Quiet™ False Alarm Control button which, when activated, will quiet unwanted CO alarms for up to 6 minutes. Installation/Interconnect • This CO alarm should be installed only by a licensed qualified electrician.

Summary of the content on the page No. 3

110-1125C Eng 2/22/06 11:32 AM Page 3 CAUTION Do not use super glue or silicon caulk on or near the alarm! Fumes from these products can coat and permanently damage the sensor. Installing a Battery (DC) Only Stand-Alone Alarm Model COE-B (10200 Series) 1. Remove the mounting plate. Hold the alarm and turn the mounting plate clockwise to separate it from the back of the alarm. 2. Hold the mounting plate against the ceiling or wall in the desired position and use a pencil to trace the mounting

Summary of the content on the page No. 4

110-1125C Eng 2/22/06 11:32 AM Page 4 IMPORTANT! READ BEFORE INSTALLING THIS CO ALARM WITH EXISTING INTERCONNECTED FIREX ALARMS In residential homes, there are two ways smoke and CO alarms are hardwire installed and interconnected. One uses 4 wires, the other uses 3 wires. The model COE and COEA CO alarms can be used with both 4 and 3 wire systems. 1. Identify whether the installed system uses 3 or 4 wires to interconnect. 2. If a 4-wire system is installed, change the system to a 3-wire by c

Summary of the content on the page No. 5

110-1125C Eng 2/22/06 11:32 AM Page 5 UNDERSTANDING THE ALARM HORN CONDITION AC power is present Standby condition Push-to-Test (Local Test Only) Press-and-Hold (Local and Interconnect Tests) Horn beeps once per minute Smart Quiet™ Low-Battery #1 Horn beeps once per minute Smart Quiet™ Low-Battery #2 Horn sounds two quick beeps Fault condition every minute Horn sounds 4 short tone Local CO condition is detected patterns every 5 seconds Local CO condition is latched Quick Quiet™ CO Reset is a

Summary of the content on the page No. 6

110-1125C Eng 2/22/06 11:32 AM Page 6 LED AND HORN PATTERNS LIGHTS SMART BUTTON KEY GREEN light ON Quick push activates a local YELLOW light blinks once per Push-to-Test sequence minute YELLOW light blinks during horn Press and RELEASE button ramp-up. before you hear the third chirp. The system will perform a single RED blinks 4 times right after local test cycle. horn sounds. Press and HOLD button. YELLOW light blinks during horn The system will perform a single ramp-up. local test cycle, t

Summary of the content on the page No. 7

110-1125C Eng 2/22/06 11:32 AM Page 7 IMPORTANT SAFETY INFORMATION CO Home Safety Tips CO poisoning is often caused by equipment failures due to poor maintenance, prod- uct defects, and damaged parts. The following tips can help prevent CO within your home: 1. Have all fuel-burning appliances inspected and cleaned yearly by a qualified serv- ice technician. The furnace, water heater, and stove are some of the leading sources of CO. 2. Clean fireplace vents and chimney regularly. A blocked ch

Summary of the content on the page No. 8

110-1125C Eng 2/22/06 11:32 AM Page 8 TESTING AND MAINTENANCE Testing • Stand-alone units: Test each alarm regularly to be sure it is operating properly. • Interconnected units: Test each alarm in an interconnected system regularly. • The Smart Button accurately tests all functions. DO NOT use an open flame to test this CO alarm. You may ignite and damage the smoke alarm or your home. • Test alarms weekly and upon returning from vacation or when no one has been in the household for several


Alternative user manuals
# User manual Category Download
1 Firex COQ1 User manual Carbon Monoxide Alarm 1
2 Firex COQ3 User manual Carbon Monoxide Alarm 2
3 Firex COQ6 User manual Carbon Monoxide Alarm 0
4 Firex pmn User manual Carbon Monoxide Alarm 0
5 3M MACURCO GD-2 User manual Carbon Monoxide Alarm 20
6 Airflow Systems IAQ10 User manual Carbon Monoxide Alarm 1
7 Aico Ei261DENRC User manual Carbon Monoxide Alarm 1
8 Advantech PCI-1718 Series User manual Carbon Monoxide Alarm 1
9 3M MACURCO GD-6 User manual Carbon Monoxide Alarm 55
10 Aico Ei261ENRC User manual Carbon Monoxide Alarm 14
11 Airflow Systems IAQ50 User manual Carbon Monoxide Alarm 10
12 American Sensor CO900 User manual Carbon Monoxide Alarm 0
13 American Sensor CO910 User manual Carbon Monoxide Alarm 1
14 American Sensor CO920 User manual Carbon Monoxide Alarm 1
15 Bacharach 2800 User manual Carbon Monoxide Alarm 0