Mitsubishi Electronics PRH-5 user manual

User manual for the device Mitsubishi Electronics PRH-5

Device: Mitsubishi Electronics PRH-5
Category: Air Conditioner
Manufacturer: Mitsubishi Electronics
Size: 1.24 MB
Added : 7/9/2013
Number of pages: 60
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Mitsubishi Electronics PRH-5. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Mitsubishi Electronics PRH-5.

For your convenience

If looking through the Mitsubishi Electronics PRH-5 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Mitsubishi Electronics PRH-5 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Mitsubishi Electronics PRH-5 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Mitsubishi Electronics PRH-5 User manual - Online PDF
Advertisement
« Page 1 of 60 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Mitsubishi Electronics PRH-5 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Mitsubishi Electronics PRH-5. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS
Series
:
COOLING ONLY PR-5,8,10,15,20
:
HEAT PUMP PRH-5,8,10,15,20
PRH-5,8,10,15,20-L
DATA BOOK

Summary of the content on the page No. 2

CONTENTS SAFETY FOR USE-----------------------------------------------------2 A COMPLETE LINE UP-----------------------------------------------4 FEATURES ---------------------------------------------------------------5 DESCRIPTIONS --------------------------------------------------------6 MECHANICAL SPECIFICATIONS----------------------------------6 TYPICAL INSTALLATION EXAMPLE------------------------------7 SPECIFICATIONS ------------------------------------------------------8 ELECTRICAL DATA --

Summary of the content on the page No. 3

SAFETY FOR USE Before conducting installation work, please read this ''SAFETY FOR USE'' carefully for correct installation. Since the caution items shown here contain important description relative to safety, please observe them without fail. Erroneous handling gives a high possibility to induce serious results such as Warning death or heavy injury. Erroneous handling may induce serious injury depending on the situation. Caut

Summary of the content on the page No. 4

Caution Arrange the configuration of wiring not to bring up Refrain from installing the unit in an area where the panel and terminal cover, and fasten the panel flammable gas can accumulate around the unit. and terminal cover securely. If the flammable gas can accumulate around the unit, an The poor mounting of the panel or terminal cover may explosion can occur. cause the heat generation of the terminal connection, When the unit is installed at telecommunication a fire or electrical shock. cent

Summary of the content on the page No. 5

A COMPLETE LINE UP PR-5YC PRH-5YA PRH-5YA-L (PRH ONLY) Cooling capacity Heatling capacity 14,000 kcal/h 13,000 kcal/h 55,600 BTU/h 51,600 BTU/h 16.3 kW 15.1 kW PR-8YC PRH-8YA PRH-8YA-L (PRH ONLY) Cooling capacity Heatling capacity 20,500 kcal/h 19,800 kcal/h 81,300 BTU/h 78,600 BTU/h 23.8 kW 23 kW PR-10YC PRH-10YA PRH-10YA-L (PRH ONLY) Cooling capacity Heatling capacity 25,500 kcal/h 27,500 kcal/h 101,200 BTU/h 109,100 BTU/h 29.7 kW 32 kW PR-15YC PRH-15YA PRH-15YA-L (PRH ONLY) Heatling ca

Summary of the content on the page No. 6

FEATURES High Sensible Cooling Capacity Labor Saving Installation The sensible cooling capacity has been significantly Because of the single unit configuration, all improved through optimized heat exchanger design. refrigeration work can be omitted. The unit operation can commence immediately after connection to the power supply, drain piping, ducting and control system. Comfort Heating The PRH series are designed to provide effective heating even when the outside temperature is down to 0˚C. Th

Summary of the content on the page No. 7

DESCRIPTIONS compressors, air-cooled condensers, evaporator MITSUBISHI ELECTRIC Rooftop Air Conditioners fans, condenser fans and auxiliary and control Series PR,PRH,RPH-L are available in a wide equipment, completely packaged in a water-proof range of sizes and models to enable the designer enclosure. to select the best model for each application. With the development of all series demands for The complete range has been designed for such features as light weight, compactness, outdoor installat

Summary of the content on the page No. 8

TYPICAL INSTALLATION EXAMPLE PR PRH PRH-L - 7-

Summary of the content on the page No. 9

SPECIFICATIONS PR-5YC PR-8YC PR-10YC PR-15YC PR-20YC PRH-5YA PRH-8YA PRH-10YA PRH-15YA PRH-20YA ITEM PRH-5YA-L PRH-8YA-L PRH-10YA-L PRH-15YA-L PRH-20YA-L kW 16.3 23.8 29.7 46.3 60.8 TOTAL COOLING CAPACITY BTU/h 55,600 81,300 101,200 157,900 207,500 (GROSS) kcal/h 14,000 20,500 25,500 39,800 52,300 kW 13 19.7 25.3 38.4 50.2 SENSIBLE COOLING CAPACITY BTU/h 44,400 67,100 86,500 130,900 171,400 (GROSS) kcal/h 11,200 16,900 21,800 33,000 43,200 kW 15.1 23 32 45.5 61.2 TOTAL HEATING CAPACIT

Summary of the content on the page No. 10

ELECTRICAL DATA Cooling PR-5YC PR-8YC PR-10YC PR-15YC PR-20YC PRH-5YA PRH-8YA PRH-10YA PRH-15YA PRH-20YA VOLT ITEM PRH-5YA-L PRH-8YA-L PRH-10YA-L PRH-15YA-L PRH-20YA-L TOTAL INPUT kW 5.4 8.3 11.4 16.8 22.7 TOTAL RUN CURRENT A 10.3 15.9 20.2 30.8 39.1 POWER FACTOR % 73 73 79 76 81 START CURRENT A 62 87 100 115 135 415V COMPRESSOR INPUT kW 3.92 6.46 9.22 2 X 6.55 2 X 9.30 RUN CURRENT A 7.44 11.70 15.62 2 X 11.74 2 X 15.22 I/D FAN INPUT kW 1.24 1.30 1.64 2.62 3.02 RUN CURRE

Summary of the content on the page No. 11

CAPACITY TABLES - 10 - Cooling Capacity (Nominal Air Flow):PR-5YC, PRH-5YA, PRH-5YA-L PR-5YC OPERATION PRH-5YA-L RANGE PRH-5YA OUTDOOR DB ˚C INDOOR INDOOR 20.0 25.0 30.0 35.0 40.0 46.0 DB ˚C WB ˚C Q kW SHC kW SHF T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW SHF T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW SHF T/I kW 15 16.4 11.3 0.69 4.5 15.8 11.1 0.70 4.7 15.2 10.8 0.71 4.9 14.5 10.4 0.72 5.1 13.8 10.1 0.73 5.4 13.0 9.8 0.75 5.7 20 16 16.9 10.3 0.61 4.6 16.3 10.1 0

Summary of the content on the page No. 12

- 11 - Cooling Capacity (Nominal Air Flow) Heating Capacity (Use for low ambient temp. parts):PR-5YC, PRH-5YA, PRH-5YA-L (Nominal Air Flow):PRH-5YA, PRH-5YA-L PRH-5YA-L OPERATION PR-5YC OPERATION PRH-5YA RANGE PRH-5YA-L RANGE PRH-5YA OUTDOOR WB ˚C INDOOR -10.0 -5.0 0.0 OUTDOOR DB ˚C DB ˚C Q kW T/I kW Q kW T/I kW Q kW T/I kW INDOOR INDOOR 0.0 5.0 10.0 15.0 -5.0 15 9.5 3.7 11.2 3.8 13.1 4.0 DB ˚C WB ˚C Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T

Summary of the content on the page No. 13

- 12 - Cooling Capacity (Nominal Air Flow):PR-8YC, PRH-8YA, PRH-8YA-L PR-8YC OPERATION PRH-8YA-L RANGE PRH-8YA OUTDOOR DB ˚C INDOOR INDOOR 20.0 25.0 30.0 35.0 40.0 46.0 DB ˚C WB ˚C Q kW SHC kW SHF T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW SHF T/I kW Q kW SHC kW S H F T/I kW 15 22.8 16.2 0.71 6.9 22.3 15.8 0.71 7.2 21.7 15.6 0.72 7.5 21.0 15.3 0.73 7.8 20.3 15.0 0.74 8.2 19.4 14.7 0.76 8.7 23.5 14.8 0.63 6.9 22.9 14.4 0.63 20 16 7.2 22.3

Summary of the content on the page No. 14

- 13 - Cooling Capacity (Nominal Air Flow) Heating Capacity (Use for low ambient temp. parts):PR-8YC, PRH-8YA, PRH-8YA-L (Nominal Air Flow):PRH-8YA, PRH-8YA-L PRH-8YA-L PR-8YC OPERATION OPERATION PRH-8YA PRH-8YA-L RANGE RANGE PRH-8YA OUTDOOR WB ˚C OUTDOOR DB ˚C INDOOR - 1 0 -5.0 0.0 DB ˚C Q kW T/I kW Q kW T/I kW Q kW T/I kW INDOOR INDOOR 0.0 5.0 10.0 15.0 -5.0 15 15.4 5.3 17.6 5.6 20.1 6.1 DB ˚C WB ˚C Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T

Summary of the content on the page No. 15

- 14 - Cooling Capacity (Nominal Air Flow):PR-10YC, PRH-10YA, PRH-10YA-L PR-10YC OPERATION PRH-10YA-L RANGE PRH-10YA OUTDOOR DB ˚C INDOOR INDOOR 20.0 25.0 30.0 35.0 40.0 46.0 DB ˚C WB ˚C Q kW SHC kW SHF T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW SHF T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW SHF T/I kW 15 29.4 21.2 0.72 9.5 28.4 20.7 0.73 9.8 27.3 20.2 0.74 10.2 26.1 19.6 0.75 10.7 24.4 18.5 0.76 11.2 23.3 18.4 0.79 11.9 20 16 30.4 19.5 0.64 9.6 29.4 18.8 0.64 9

Summary of the content on the page No. 16

- 15 - Cooling Capacity (Nominal Air Flow) Heating Capacity (Use for low ambient temp. parts):PR-10YC, PRH-10YA, PRH-10YA-L (Nominal Air Flow):PRH-10YA, PRH-10YA-L PRH-10YA-L OPERATION PR-10YC OPERATION RANGE PRH-10YA PRH-10YA-L RANGE PRH-10YA OUTDOOR WB ˚C INDOOR -10.0 -5.0 0.0 OUTDOOR DB ˚C DB ˚C Q kW T/I kW Q kW T/I kW Q kW T/I kW INDOOR INDOOR 0.0 5.0 10.0 15.0 -5.0 15 21.5 7.6 24.6 7.9 28.0 8.4 DB ˚C WB ˚C Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T/I kW Q kW S

Summary of the content on the page No. 17

- 16 - Cooling Capacity (Nominal Air Flow):PR-15YC, PRH-15YA, PRH-15YA-L PR-15YC OPERATION PRH-15YA-L RANGE PRH-15YA OUTDOOR DB ˚C INDOOR INDOOR 20.0 25.0 30.0 35.0 40.0 46.0 DB ˚C WB ˚C Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T/I kW 15 44.5 32.0 0.72 13.9 43.3 31.2 0.72 14.5 42.0 30.7 0.73 15.2 40.8 30.2 0.74 15.9 39.5 29.6 0.75 16.6 37.8 29.1 0.77 17.5 20 16 45.7 29.2 0.64 14.0 44.5 28.5 0.64 14

Summary of the content on the page No. 18

- 17 - Cooling Capacity (Nominal Air Flow) Heating Capacity (Use for low ambient temp. parts):PR-15YC, PRH-15YA, PRH-15YA-L (Nominal Air Flow):PPRH-15YA, PRH-15YA-L PRH-15YA-L OPERATION PR-15YC OPERATION RANGE PRH-15YA PRH-15YA-L RANGE PRH-15YA OUTDOOR WB ˚C INDOOR -10.0 -5.0 0.0 OUTDOOR DB ˚C DB ˚C Q kW T/I kW Q kW T/I kW Q kW T/I kW INDOOR INDOOR 0.0 5.0 10.0 15.0 -5.0 15 31.0 10.7 35.1 11.4 39.9 12.2 DB ˚C WB ˚C Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T/I kW Q

Summary of the content on the page No. 19

- 18 - Cooling Capacity (Nominal Air Flow):PR-20YC, PRH-20YA, PRH-20YA-L PR-20YC OPERATION PRH-20YA-L RANGE PRH-20YA OUTDOOR DB ˚C INDOOR INDOOR 20.0 25.0 30.0 35.0 40.0 46.0 DB ˚C WB ˚C Q kW SHC kW SHF T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW S H F T/I kW 15 59.3 42.7 0.72 18.7 57.4 41.9 0.73 19.5 55.4 40.4 0.73 20.3 53.4 39.5 0.74 21.3 51.4 38.6 0.75 22.3 48.8 37.6 0.77 23.6 20 16 61.3 39.2 0.64 19.0 59.5 38.1

Summary of the content on the page No. 20

- 19 - Cooling Capacity (Nominal Air Flow) Heating Capacity (Use for low ambient temp. parts):PR-20YC, PRH-20YA, PRH-20YA-L (Nominal Air Flow):PRH-20YA, PRH-20YA-L PR-20YC OPERATION PRH-20YA-L PRH-20YA-L OPERATION RANGE PRH-20YA PRH-20YA RANGE OUTDOOR DB ˚C OUTDOOR WB ˚C INDOOR -10.0 -5.0 0.0 0.0 5.0 10.0 15.0 INDOOR INDOOR -5.0 DB ˚C Q kW T/I kW Q kW T/I kW Q kW T/I kW DB ˚C WB ˚C Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T/I kW Q kW SHC kW


Alternative user manuals
# User manual Category Download
1 Mitsubishi Electronics 15 User manual Air Conditioner 120
2 Mitsubishi Electronics 20-L User manual Air Conditioner 11
3 Mitsubishi Electronics 2.5KKC User manual Air Conditioner 14
4 Mitsubishi Electronics 20-MYA User manual Air Conditioner 16
5 Mitsubishi Electronics 8 User manual Air Conditioner 3
6 Mitsubishi Electronics A18AR User manual Air Conditioner 4
7 Mitsubishi Electronics CITY MULTI PKFY-PVAM-A User manual Air Conditioner 43
8 Mitsubishi Electronics CMB-P-V-F User manual Air Conditioner 12
9 Mitsubishi Electronics CITY MULTI PUHY-YMC User manual Air Conditioner 227
10 Mitsubishi Electronics A12 User manual Air Conditioner 27
11 Mitsubishi Electronics LOSSNAY LGH-100RX4-E User manual Air Conditioner 45
12 Mitsubishi Electronics LOSSNAY LGH-150RX4-E User manual Air Conditioner 18
13 Mitsubishi Electronics G-50A User manual Air Conditioner 458
14 Mitsubishi Electronics 20 PRH-5 User manual Air Conditioner 7
15 Mitsubishi Electronics LOSSNAY LGH-200RX4-E User manual Air Conditioner 16
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21