Mitsubishi Electronics PFD-P250500VM-A user manual

User manual for the device Mitsubishi Electronics PFD-P250500VM-A

Device: Mitsubishi Electronics PFD-P250500VM-A
Category: Air Conditioner
Manufacturer: Mitsubishi Electronics
Size: 0.49 MB
Added : 7/9/2013
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Mitsubishi Electronics PFD-P250500VM-A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Mitsubishi Electronics PFD-P250500VM-A.

For your convenience

If looking through the Mitsubishi Electronics PFD-P250500VM-A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Mitsubishi Electronics PFD-P250500VM-A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Mitsubishi Electronics PFD-P250500VM-A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Mitsubishi Electronics PFD-P250500VM-A User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Mitsubishi Electronics PFD-P250500VM-A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Mitsubishi Electronics PFD-P250500VM-A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Air-Conditioners
INDOOR UNIT

PFD-P250 500VM-A
OPERATION MANUAL
For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
BEDIENUNGSHANDBUCH
Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
MANUEL D’UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d’utilisation en entier avant de vous servir du climatiseur.
MANUAL DE INSTRUCCIONES
Lea e

Summary of the content on the page No. 2

I Bottone dell’unità del comando a distanza GB E Remote controller-Button Controlador remoto-Botón D NL Fernbedienungs-Taste Knop afstandbediening F RU Touche Commande à distance Кнопка контроллера ДУ 1 Pulsante [Regolazione della temperatura ambiente] 2 Pulsante [Timer/continuo] 3 Pulsante [Selezione modalità di funzionamento] 4 Pulsante [Selezione ora] Pulsante [Impostazione dell’ora] CENTRALLY CONTROLLED 1Hr. 5 Pulsante [Regolazione deflettore] ON OFF ˚C CLOCK CHECK FILTER 6 Pulsante [Regolaz

Summary of the content on the page No. 3

I Bottone dell’unità del comando a distanza GB E Remote controller-Button Controlador remoto-Botón D NL Fernbedienungs-Taste Display afstandbediening F RU Affichage Commande à distance Кнопка контроллера ДУ A B C D A B C F G No.1 No.2 Power Operating Check Failure Power Operating Check Failure Failure PFD-P250VM-A PFD-P500VM-A A Spia alimentazione B Spia funzionamento C Spia di controllo D Spia guasto E Commutatore Normal/Local F Spia guasto n.1 Local Local G Spia guasto n.2 TEST RUN TEST RUN TE

Summary of the content on the page No. 4

[Fig. A] [Fig. B-1] B Parallel A K (minutes) Remarks Pulley Cast iron pulley 10 or less Equivalent to 3 mm displacement per meter. K K K D K K E SWC SWC C [Fig. B-2] A Address board B Control board C Address board D Option: Inlet temperature control E Standard: Outlet temperature control A Deflection load (W) 3 - 4kg = 5mm 4

Summary of the content on the page No. 5

Contents 1. Safety precautions ...................................................................................... 5 4. “Failure” Display Lamps .............................................................................. 8 1.1. Installation ................................................................................. 5 5. Control of Indoor Unit Inlet or Outlet Temperature ...................................... 8 1.2. During operation .....................................................

Summary of the content on the page No. 6

• Ensure that the drain trap is properly water-sealed. In case of failure - If the drain trap is modified, or is not water-sealed, the trap will not function and a water leak may occur. Inject water into the hose during the periodic Warning: check (six-monthly) to check water-sealing. • Never remodel the unit. Consult your dealer for any repair service. Improper repair work can result in water leakage, electric shock, fire, etc. Warning: • If the remote controller displays an error indication,

Summary of the content on the page No. 7

3.2. Selecting operation Caution: When the current time is not yet set, the “CLOCK (current time)” display When selecting operation flashes, disabling the setting of timer operation. 33 1. Press the 333 [selecting operation] button 44 2. Set the current time by pressing the 444 or button Consecutive press of the selecting operation button switches the operation over to E “ ,” “ ,” “ ,” (“ ”), and (“ ”). For the contents of operation, • The time cannot be set while the C “timer on” is displayed

Summary of the content on the page No. 8

• Remote ON/OFF input and ON/OFF from the central controller (optional) 3.6. Selecting Normal and Local Operation are disabled in the Local operation mode. • See the central controller users manual for details of ON/OFF from the Selecting Local operation central controller (optional) and input of temperature settings. Set the Normal/Local switch C to local. • Selecting ON/OFF from the remote controller requires a few seconds. Start and stop is only possible with the remote controller (remote ON/

Summary of the content on the page No. 9

8. Troubleshooting Before you ask for repair service, check the following points: State of Machine Remote Controller Cause Troubleshooting “'” display is not lit up Power failure Press the [ON/OFF] button after power restoration. No display appears even The power supply is turned OFF. Turn the power supply ON. It does not run. when the [ON/OFF] but- The fuse in the power supply is gone. Replace fuse. ton is pressed. The earth leakage breaker is gone. Put in the earth leakage breaker. After check

Summary of the content on the page No. 10

10. Checking Drainage Check that water is able to drain smoothly. If water is unable to drain smoothly, check for blockage of the grooves in the drain pan and the piping trap by paper particles etc. Carefully clean the grooves in the drain pan and the piping trap to prevent further blockage. Ensure that the trap is always water-sealed. 11. Checking V Belts 1. Adjust parallel of the fan and motor pulleys in accordance with Fig.B-1. 2. Adjust the tension of each V belt so that the deflection load

Summary of the content on the page No. 11

15. Periodic Checks Table 1 Maintenance and Checks Unit Parts Check frequency Checks Evaluation criteria Maintenance • Check operating noise. • No abnormal noises. Replace if insulation has deteriorated. Fan motor • Measure insulation resistance. • Insulation resistance 1 MΩ or more. • Check operating noise. • No abnormal noises. Replace if abnormal noises continue de- Bearing spite replenishing oil. Replenish oil annually. • Check belt tension. • Deflection load of 3 - 4kg per belt. Opti- Adjus

Summary of the content on the page No. 12

16. Specifications PFD-P·VM-A series Model PFD-P250VM-A PFD-P500VM-A Item Power source 3N~/380-415V (50Hz), 400-415V (60Hz) Cooling capacity*1 kW 28 56 Height mm 1895 Dimension Width mm 1200 1800 Depth mm 800 Net weight kg 350 480 3 Fan Airflow rate (Low-Middle-High) m /min 160 320 Noise level*2 dB(A) 59 64 Filter Long life filter Indoor Outdoor Dry bulb temperature – –5 °C~43 °C Wet bulb temperature 12 °C~24 °C – Notes: *1 Cooling capacity indicates the maximum value at operation under the fo

Summary of the content on the page No. 13

HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Printed in Japan WT04232X01

Summary of the content on the page No. 14

               


Alternative user manuals
# User manual Category Download
1 Mitsubishi Electronics 15 User manual Air Conditioner 120
2 Mitsubishi Electronics 20-L User manual Air Conditioner 11
3 Mitsubishi Electronics 2.5KKC User manual Air Conditioner 14
4 Mitsubishi Electronics 20-MYA User manual Air Conditioner 16
5 Mitsubishi Electronics 8 User manual Air Conditioner 3
6 Mitsubishi Electronics A18AR User manual Air Conditioner 4
7 Mitsubishi Electronics CITY MULTI PKFY-PVAM-A User manual Air Conditioner 43
8 Mitsubishi Electronics CMB-P-V-F User manual Air Conditioner 12
9 Mitsubishi Electronics CITY MULTI PUHY-YMC User manual Air Conditioner 227
10 Mitsubishi Electronics A12 User manual Air Conditioner 27
11 Mitsubishi Electronics LOSSNAY LGH-100RX4-E User manual Air Conditioner 45
12 Mitsubishi Electronics LOSSNAY LGH-150RX4-E User manual Air Conditioner 18
13 Mitsubishi Electronics G-50A User manual Air Conditioner 458
14 Mitsubishi Electronics 20 PRH-5 User manual Air Conditioner 7
15 Mitsubishi Electronics LOSSNAY LGH-200RX4-E User manual Air Conditioner 16