HI-E-Dry Vehere
Part Number 4025276
Owner’s Manual — HI-E Dry Vehere
Installation, Operation & Service Instructions
Read and Save These Instructions
TM
The HI-E DRY Vehere Pool & Spa Humidity Controller featuring FOCUS Technology is the industries
most efficient, durable and economic product for controlling moisture related problems associated
with indoor pools, whirlpools, hot tubs, and therapy/lap pools.
Vehere delivers comfort and solves:
• Chemical Odors • Foggy Windows • Mold
Summary of the content on the page No. 2
Table of Contents 1 Intended Application 1. Intended Application for Vehere .............................. The intended application for the Vehere is as a pool & 2. Specifications & Capacities .................................... spa area humidity sensing controller applied either as a 2. V ehere Diagram ...............................................2 free-standing device directly in the pool area or operated 3. Installation ............................................................2
Summary of the content on the page No. 3
2.1 Vehere Diagram 3 Installation Options A - Air Intake 3.1 Location B - Humidity Sensor/Control The Vehere can be installed in a variety of locations to meet C - Filters the owner’s needs; other considerations include: D - Air Exhaust . Providing access to a 5 VAC power outlet (7’ power E - Fan Switch cord is provided). F - Power Cord 2. Locating near a floor or other suitable drain (4’ drain hose included). G - Drain Hose 36.5” 3.1A Improper Installation A Do not install the Vehere wit
Summary of the content on the page No. 4
Quiet-Vent Quiet-Vent Direct Warm & Dry Air Optional Quiet-Vent Toward Window Glass Exhaust Ventilator Low = 165 CFM high = 290 CFM Vehere Pool & Spa Humidity Controller Dehumidistats for Quiet-Vent and remote Vehere Figure 4: Installation in humid area with ducting. 3.1C In Humid Area, Duct Inlet and/or Outlet 3.1D In Remote Area, Duct Inlet & Outlet If the pool room is very large or has high ceilings, It is often desirable, to install the Vehere in an adjacent dehumidification can be impro
Summary of the content on the page No. 5
3.2 Mounting The Remote Humidity Sensor/ 3.4 Condensate Removal Controller Condensate drains by gravity via the clear hose extending from the unit. Route the 4’ drain hose to a floor drain. If the Vehere is to be located in a remote location outside Use care to keep the hose as flat to the floor as possible. the pool or spa area, mounting of the humidity sensor in Keep the hose away from walk ways if possible. Excessive the space to be conditioned is necessary. If the humidity humps or ki
Summary of the content on the page No. 6
3.5B Ducting for Dehumidification Approximate Humidity Levels Per Setting “Low” 35% to 45% Relative Humidity Ducting the Vehere as mentioned requires consideration of the following points: “Normal” 45% to 55% Relative Humidity (Recommended) “High” 55% to 65% Relative Humidity The Vehere will require a single 2” round or equivalent dedicated return from the pool room. The Vehere A quality humidity meter is recommended to accurately supply can be dedicated or tapped into a forced air mo
Summary of the content on the page No. 7
The evaporator operates in a flooded condition, which 5 Ventilation means it should always be full of liquid refrigerant during normal operation. A flooded evaporator should maintain constant pressure and temperature across the entire coil, WARNING: Do not use open combustion heating appliances from inlet to outlet. A mixture of gas and liquid refrigerant (unless equipped with power exhaust) in a pool room equipped enter the accumulator after leaving the evaporator coil. The with exhaust
Summary of the content on the page No. 8
Evaporator coil frosted continuously, low dehumidifying 7.5 Low Pressure Control capacity. If the low side refrigerant pressure drops to 5 PSIG, the . Defrost thermostat loose or defective low pressure control opens and shuts off the compressor and blower. It is automatically reset. It will close when the 2. Low refrigerant charge refrigerant pressure rises to 35 PSIG. Its primary function 3. Dirty air filters or airflow restricted. is to prevent damage to the compressor if a leak dev
Summary of the content on the page No. 9
9 Vehere Electrical Wiring Figure 12: Vehere wiring diagram. Toll-Free -800-533-7533 www.thermastor.com • sales@thermastor.com 9
Summary of the content on the page No. 10
10 Service Parts ITEM PART NO. QTY. DESCRIPTION 402083 Blower with Capacitor 2 4022740 Capacitor, Run, 30MFD, 370v 3 407777 2 Capillary Tubes, .059” ID x 32” long 4 4023604 4 Caster, 2”, Plastic, Swivel 5 4023533 Coil, Condenser 6 4023534 Coil, Evaporator 7 4025738 Compressor Service Assembly—includes compressor, capacitor and overload 4022595 Compressor Overload 8 402229 Control, Low Pressure 9 4025278 Cord & Wire Harness 0 402470 Defrost Thermostat 402648
Summary of the content on the page No. 11
HI-E DRY Vehere Dehumidifier Limited Warranty Warrantor: Therma-Stor LLC PO Box 8680 Madison, WI 53708 Telephone: -800-533-7533 Warranty: This warranty covers the HI-E Dry Vehere. Year One - 00% parts and labor (all components) Year(s) Two through Five - The condenser, evaporator and compressor of the HI-E Dry Vehere will operate free of any defects in material or will repair or replace the defective part(s). If a defect in materials or workmanship occurs within the warranty period, Therma-