Sterling STT70 user manual

User manual for the device Sterling STT70

Device: Sterling STT70
Category: Dehumidifier
Manufacturer: Sterling
Size: 1.45 MB
Added : 10/3/2013
Number of pages: 76
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sterling STT70. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sterling STT70.

For your convenience

If looking through the Sterling STT70 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sterling STT70 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sterling STT70 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sterling STT70 User manual - Online PDF
Advertisement
« Page 1 of 76 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sterling STT70 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sterling STT70. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Operation Instructions
Dehumidified air dryer
STT40
STT70
Sterling Material Processing

Summary of the content on the page No. 2

STT40 / STT70 Sterling Material Processing 5200 West Clinton Ave. Milwaukee, WI 53223 Telephone: (414) 354-0970 Fax: (414) 354-6421 www.sterlco.com Technical service: Service department Telephone: (800) 423-3183 Edition: 07/03 These operation instructions are for*: (* please fill in personally) Serial number: Year of manufacture: Date of Delivery: Number of delivery: Date commissioned: Location: Group of machines: 2

Summary of the content on the page No. 3

STT40 / STT70 Sterling Material Processing retains all rights to change the information in these operation instructions at any time without notice. We assume no liability for any errors from direct or indirect damage resulting in context with these operation instructions. Copying, translation or publication in any form except for personal use by the purchaser requires approval from Sterling Material Processing. All rights reserved. 3

Summary of the content on the page No. 4

STT40 / STT70 Table of contents 1. General Information................................................................................................. 1-1 1.1. Warnings and symbols..........................................................................................1-1 1.2. Explanations and information............................................................................... 1-3 1.3. Legal basis ...........................................................................................

Summary of the content on the page No. 5

STT40 / STT70 8.2. Grounding the equipment against electrostatic charging......................................8-2 8.3. Electrical Connection............................................................................................8-3 8.4. Connection of Return Air Cooler (Optional)........................................................ 8-4 9. Troubleshooting .......................................................................................................9-1 9.1. Introduction............

Summary of the content on the page No. 6

STT40 / STT70 1. General Information  These operation instructions are addressed to all users of this device. These operation instructions must be followed by every person working on or with the unit. 1.1. Warnings and symbols The following warnings and symbols are used in these operating instructions:  This symbol indicates danger to life! Fatal or serious injury is possible if the corresponding instructions, regulations or warnings are not observed. This symbol indicates that serious injury

Summary of the content on the page No. 7

STT40 / STT70 When disposing of drying agents / batteries / oil, observe all official rules. Caution: High noise pollution ! For anyone working on the equipment, hearing protection should be worn. Avoid impairment of hearing! Caution: Danger of being crushed ! Disconnect the equipment from the main power supply before starting maintenance procedures. All compressed air pipes on the equipment should be depressurized before starting maintenance work. Caution: Danger, surface is hot ! Before start

Summary of the content on the page No. 8

STT40 / STT70 1.2. Explanations and information Various terms and designations are used in these operating instructions to ensure clarity. Therefore please note that the terms used in the text stand for the corresponding explanations listed below. • Equipment: ”Equipment” can mean an individual unit, a machine or an installation. • Operating personnel: The ”operating personnel” are persons operating the equipment under their own responsibility or according to instructions. • Operator: The ”oper

Summary of the content on the page No. 9

STT40 / STT70 2. Safety instructions  These safety instructions apply to all persons around the operating equipment. Please inform all persons around the operating equipment of the direct and indirect hazards connected with it. These operation instructions are to be used by all persons assigned activities connected with the equipment. Knowledge of the English language is a prerequisite. For your safety, ensure that the operating personnel are familiar with the operating instructions and the fun

Summary of the content on the page No. 10

STT40 / STT70 2.1 General The operating personnel of this equipment must be at least 16 years old. Please read these operation instructions carefully before operating the equipment for the first time. Contact us should questions arise. This avoids injury and damage to equipment! These operation instructions must be kept available at all times at the place where the equipment is operating. Improper operation results in danger of accidents! Please note that not all conceivable cases regarding oper

Summary of the content on the page No. 11

STT40 / STT70 2.1.1. Assembly Compare the connected loads with those of the main power supply. Danger, electrical shock hazard! When using lifting gear, please observe the pertaining regulations. Caution: Danger of accidents! Do not modify, add other equipment or change the design of the equipment without the approval of the manufacturer. Caution: Danger of accidents! Attachments not supplied by Sterling must be manufactured in accordance with safety regulation EN 294. Danger of accidents! The e

Summary of the content on the page No. 12

STT40 / STT70 2.1.3. Maintenance Before starting maintenance work, appoint a supervisor. Inform personnel responsible for the system before beginning maintenance work. Caution: Danger of accidents! Disconnect the equipment from main power supply before starting maintenance procedures to ensure that it cannot be switched on unintentionally. Caution: Danger of accidents! All pipes, hoses and connections should be checked regularly for leaks and damage. Any faults which arise should be corrected im

Summary of the content on the page No. 13

STT40 / STT70 2.2. For the safety of the device Never change settings without carefully assessing the consequences. Use only original Sterling spare parts. Observe the maintenance instructions. Keep a record of all maintenance work and repairs. Please note that electronic components can be damaged by static discharge. Before initial operation and at regular intervals, make sure that no electrical connections are loose. Never readjust sensors without exactly knowing their functions. Please ensur

Summary of the content on the page No. 14

STT40 / STT70 3. Start up  This chapter is addressed to the operators of the machine. It assumes the operator has general skills with drying equipment and that the functional description has been read and understood. Ensure that the operators have the required experience. Make sure that the main switch is set to the “0" position. Check the drying hopper for cleanliness. Check to see whether the adhesive film on the drying hopper has been removed. If there is a return air cooler, switch on the

Summary of the content on the page No. 15

STT40 / STT70 3.1. Initial Operation Check whether the inlet of the drying hopper is closed by a lid or whether a conveyor unit (optional) is installed. If not, manufacture a suitable lid and install it on the inlet of the drying hopper or install the optional conveyor unit. Attachments which are not supplied by Sterling must be manufactured according to the European Standard 294 safety regulation. Check whether the coolant circuit of the return air cooler (if a return air cooler is installed)

Summary of the content on the page No. 16

STT40 / STT70 Turn the “Hopper” release switches (ST1, ST2) to the “I” position. To set the drying temperature, turn the temperature controller to 176° F (+80 °C). Press the “PGM” key one time. Set the drying temperature to 176° F using the arrow keys. After 2 seconds, the display will flash and the value will be stored. Press the “EXIT” key (the setpoint value and the actual value of the drying temperature are displayed). After 2 hours, turn the “Hopper” release switches (ST1, ST2) to the “0”

Summary of the content on the page No. 17

STT40 / STT70 3.2. Continuous Operation Note: To see a quick start guide for operation of this dryer see chapter 14. Fill at least half of the drying hopper with material. 3.2.1. Switching the Dryer on Turn on the dryers’ main power switch to the on position. The “run” signal lamp turns on. For operation with the optional timer clock: Turn the “Timer” switch to the position. For operation without timer clock: Turn the “Timer” switch to the position. The blower is r

Summary of the content on the page No. 18

STT40 / STT70 3.2.2. Setting the Drying Temperature Turn the “Hopper” (ST1, ST2) release switches to the “I” position. For each drying hopper, set the required process drying temperature by using the corresponding temperature controller. Check whether the set process drying temperature is appropriate for the materials which have been placed in the drying hopper. Observe the instructions of the material manufacturer. After filling the drying hopper you must wait for the resonance time of the mate

Summary of the content on the page No. 19

STT40 / STT70 Autotuning the temperature controller Press the “EXIT” key for at least 2 seconds. “tunE” flashes. Autotuning can take several minutes. If “tunE” stops flashing, Autotuning is finished. Press the “EXIT” key. Start up 3-6

Summary of the content on the page No. 20

STT40 / STT70 3.3. Switching the Dryer off Turn the “Timer” switch to the position: Wait until the blower has stopped. The blower will continue running for 10 minutes once the dryer is turned off. If there is a return air cooler installed, switch off its coolant circuit. Turn off the dryer’s main power switch. The “power” signal lamp turns off. Note: For more detailed instructions on the shutting down of this dryer, see the quick start guide in Chapter 14. Start up 3-7


Alternative user manuals
# User manual Category Download
1 Sterling SDAA 25-100 User manual Dehumidifier 0
2 Sterling SDF 250 User manual Dehumidifier 0
3 Sterling SDF 500 User manual Dehumidifier 0
4 Sterling 350-2100 CFM User manual Dehumidifier 10
5 Sterling 882.00295.00 User manual Dehumidifier 1
6 Sterling SDF 400 User manual Dehumidifier 3
7 Sterling SDA 1000-5100 User manual Dehumidifier 0
8 Sterling 90-225 CFM User manual Dehumidifier 0
9 Sterling 882.00291.00 User manual Dehumidifier 0
10 Sterling SDA AP-1 User manual Dehumidifier 1
11 Sterling SMD SERIES User manual Dehumidifier 0
12 Sterling SDA 150-380 User manual Dehumidifier 0
13 Sterling STT 110 User manual Dehumidifier 0
14 Sterling SDA Series 25-100 User manual Dehumidifier 0
15 Sterling STT 160 User manual Dehumidifier 0
16 Eaton Electrical TR3 User manual Dehumidifier 2
17 Airstream LAND YACHT MOTORHOME User manual Dehumidifier 1
18 Alen MDF-50AE User manual Dehumidifier 4
19 Alen MDF-70AE User manual Dehumidifier 2
20 Amcor D850E User manual Dehumidifier 29