Mitsubishi Electronics PE-15MYC user manual

User manual for the device Mitsubishi Electronics PE-15MYC

Device: Mitsubishi Electronics PE-15MYC
Category: Air Conditioner
Manufacturer: Mitsubishi Electronics
Size: 2.83 MB
Added : 7/9/2013
Number of pages: 115
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Mitsubishi Electronics PE-15MYC. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Mitsubishi Electronics PE-15MYC.

For your convenience

If looking through the Mitsubishi Electronics PE-15MYC user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Mitsubishi Electronics PE-15MYC on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Mitsubishi Electronics PE-15MYC to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Mitsubishi Electronics PE-15MYC User manual - Online PDF
Advertisement
« Page 1 of 115 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Mitsubishi Electronics PE-15MYC but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Mitsubishi Electronics PE-15MYC. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

AIR-COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS
DATA BOOK
Series : PE(H)
Model Service ref.
PE-7MYC PE-7MYC-EU
Cooling only
PE-8MYC PE-8MYC-EU
PE-10MYC PE-10MYC-EU
PE-15MYC PE-15MYC-EU
PE-20MYC PE-20MYC-EU
Heat pump
PEH-5MYA PEH-5MYA-EU
PEH-7MYA PEH-7MYA-EU
PEH-8MYA PEH-8MYA-EU
PEH-10MYA PEH-10MYA-EU
PEH-15MYA PEH-15MYA-EU
PEH-20MYA PEH-20MYA-EU

Summary of the content on the page No. 2

CONTENTS SAFETY FOR USE ------------------------------------------------------2 A COMPLETE LINE UP ------------------------------------------------4 FEATURES-----------------------------------------------------------------5 DESCRIPTIONS----------------------------------------------------------5 MECHANICAL SPECIFICATIONS ----------------------------------6 TYPICAL INSTALLATION EXAMPLE ------------------------------6 MODEL-DESIGNATION BREAKDOWN ---------------------------7 SPECIFICATIONS ---------

Summary of the content on the page No. 3

SAFETY FOR USE Before conducting installation work, please read this ''SAFETY FOR USE'' carefully for correct installation. Since the caution items shown here contain important description relative to safety, please observe them without fail. Erroneous handling gives a high possibility to induce serious results such as Warning death or heavy injury. Erroneous Caution handling may induce serious injury depending on the situati

Summary of the content on the page No. 4

Caution Arrange the configuration of wiring not to bring up Never install on the place where a combustible the panel and terminal cover, and fasten the panel gas might leak. and terminal cover securely. The gas may ignite or explode when the gas leaks and The poor mounting of the panel or terminal cover may collects in surround of the unit. cause the heat generation of the terminal connection, When the unit is installed at telecommunication a fire or electrical shock. centers or hospitals, tak

Summary of the content on the page No. 5

A COMPLETE LINE UP PEH-5 PE(H)-7 PE(H)-8 PE(H)-10 PE(H)-15 PE(H)-20 kW 14.4 17.9 22.0 28.8 44.0 57.6 Btu/h 49,150 61,000 75,100 98,300 150,200 196,600 Cooling capacity kcal/h 12,400 15,400 18,900 24,800 37,900 49,600 kW 14.4 18.8 22.0 28.8 44.0 57.6 Heating capacity Btu/h 49,150 64,100 75,100 98,300 150,200 196,600 (PEH only) 12,400 16,200 18,900 24,800 37,900 49,600 kcal/h Note: Cooling & heating capacities are based following conditions. Cooling: Indoor:27 DB, 19 WB; Outdoor:

Summary of the content on the page No. 6

FEATURES Labour saving installation. High sensible cooling capacity. The sensible cooling capacity has been significantly The unit operation can commence immediately after improved through balanced optimised heat connecting to the power supply, refrigerant piping, exchanger design. drain piping, ducting and control system. Comfort heating. (PEH only) Wide electrical control capability. The PEH series are designed to provide effective All series is flexible mechanical control heating even when

Summary of the content on the page No. 7

MECHANICAL SPECIFICATIONS General Condenser Coils All units are factory assembled, piped, internally wired. Unnecessary power input due to higher discharge They are also tested and checked under a strict quality pressure is avoided by high performance designs of control system in the factory. cross-finned coil. Exterior surfaces of all units of outdoor unit are Condenser coils are made of 9.52mm OD, 0.35mm phosphatized, zinc-coated steel with powder coating thick seamless copper tubes mecha

Summary of the content on the page No. 8

MODEL-DESIGNATION BREAKDOWN 1 PE-10 MY C Service reference Design Sequence Electrical Supply Y = 3 phase 380~415V 50Hz 4 wires In case of PE(H)-7 Indoor unit ( ) Y = 1 phase 220~240V 50Hz 2 wires Compressor Horsepower 5 = 5 H P 7 = 7 H P 8 = 7.5 H P 10= 10 H P 15= 15 H P 20= 20 H P Series Number PE = Indoor unit PEH = Indoor unit PU = Outdoor unit PUH = Outdoor unit - 7 -

Summary of the content on the page No. 9

SPECIFICATIONS Cooling only PE-7~20MYC Model name PE-7MYC PE-8MYC PE-10MYC PE-15MYC PE-20MYC Service PE-7MYC-EU PE-8MYC-EU PE-10MYC-EU PE-15MYC-EU PE-20MYC-EU reference Power supply Indoor 1PH 2W220~240V 50Hz 3PH 4W380 ~ 415V 50Hz Outdoor 3PH 4W 380~415V 50Hz 3PH 4W380 ~ 415V 50Hz Total cooling capacity 17.9 22.0 28.8 44.0 57.6 kW 61,100 Btu/h 75,100 98,300 150,200 196,600 15,400 18,900 24,800 37,900 49,600 kcal/h 14.3 17.6 23.0 35.2 46.1 kW Sensible cooling capacity 48,800 60,100 78,500 120,200

Summary of the content on the page No. 10

PEH-5,7,8MYA Heat pump Model name PEH-5MYA PEH-7MYA PEH-8MYA Service PEH-5MYA-EU PEH-7MYA-EU PEH-8MYA-EU reference 1PH 2W220~240V 50Hz Power supply Indoor 3PH 4W380~415V 50Hz 3PH 4W380~415V 50Hz Outdoor 3PH 4W380~415V 50Hz 3PH 4W380~415V 50Hz 3PH 4W380~415V 50Hz 14.4 17.9 22.0 Total cooling capacity kW Btu/h 49,150 61,100 75,100 kcal/h 12,400 15,400 18,900 17.6 kW 11.5 14.3 Sensible cooling capacity 39,400 48,800 60,100 Btu/h kcal/h 10,000 12,300 15,100 kW 14.4 18.8 22.0 Sensible heating capacit

Summary of the content on the page No. 11

PEH-10,15,20MYA Heat pump Model name PEH-10MYA PEH-15MYA PEH-20MYA Service PEH-10MYA-EU PEH-15MYA-EU PEH-20MYA-EU reference Power supply Indoor 3PH 4W380 ~ 415V 50Hz Outdoor 3PH 4W380 ~ 415V 50Hz 28.8 44.0 57.6 Total cooling capacity kW Btu/h 98,300 150,200 196,600 kcal/h 24,800 37,900 49,600 kW 23.0 35.2 46.0 Sensible cooling capacity 78,500 Btu/h 120,200 157,000 kcal/h 19,800 30,200 39,600 kW 28.8 44.0 57.6 Sensible heating capacity 98,300 Btu/h 150,200 196,600 kcal/h 24,800 37,800 49,500 Capa

Summary of the content on the page No. 12

ELECTRICAL DATA PE-7~20MYC-EU Cooling PE-7MYC-EU PE-8MYC-EU PE-10MYC-EU PE-15MYC-EU PE-20MYC-EU VOLT ITEM PU-7MYC1-EU PU-8MYC1-EU PU-10MYC1-EU PU-15MYC1-EU PU-20MYC1-EU TOTAL INPUT kW 7.2 7.8 10.1 17.6 22.0 TOTAL RUN CURRENT A 14.6 14.2 18.9 29.6 39.1 POWER FACTOR % - 74 74 83 78 PE-7 START CURRENT A 74 83 82 119 140 240V 6.0 6.8 8.6 2X7.65 2X9.2 COMPRESSOR INPUT kW 10.7 12.3 15.9 2X12.45 2X15.95 PE- RUN CURRENT A 8 20 0.8 0.6 1.0 1.7 2.4 INDOOR FAN IN

Summary of the content on the page No. 13

PEH-5,7,8MYA-EU Cooling PEH-5MYA-EU PEH-7MYA-EU PEH-8MYA-EU VOLT ITEM PUH-5MYE-EU PUH-7MYC1-EU PUH-8MYC1-EU PUH-8MYE-EU TOTAL INPUT kW 5.5 7.2 7.8 7.9 TOTAL RUN CURRENT A 9.5 14.6 14.2 14.7 POWER FACTOR % 80 - 76 75 PEH-7 START CURRENT A 69 74 83 83 240V 4.7 6.0 6.8 6.77 COMPRESSOR INPUT kW 8.1 10.7 12.3 12.3 PEH- RUN CURRENT A 8 20 0.54 0.8 0.6 0.6 INDOOR FAN INPUT kW 415V 0.9 3.2 1.2 1.2 RUN CURRENT A 0.25 0.4 0.4 0.53 OUTDOOR FAN

Summary of the content on the page No. 14

PEH-10,15,20MYA-EU Cooling PEH-10MYA-EU PEH-15MYA-EU PEH-20MYA-EU VOLT ITEM PUH-10MYC1-EU PUH-10MYE-EU PUH-15MYC1-EU PUH-20MYC1-EU TOTAL INPUT kW 10.1 10.2 16.9 21.8 TOTAL RUN CURRENT A 18.9 19.1 30.9 39.3 POWER FACTOR % 74 74 76 77 PEH-7 START CURRENT A 82 82 119 140 240V 8.57 8.67 2X6.77 2X9.12 COMPRESSOR INPUT kW 15.9 15.9 2X12.2 2X16.1 PEH- RUN CURRENT A 8 20 1.0 1.0 2.3 2.5 INDOOR FAN INPUT kW 415V 2.0 2.0 4.1 4.7 RUN CURRENT A

Summary of the content on the page No. 15

SELECTION PROCEDURE 1. Model Selection (With actual examples) First step, to select the approximate model: Based on the cooling load and the cooling capacity listed in the capacity table, select the applicable model. Second step, to select the model: To select the model, the following conditions must be known: (1) Total cooling load or sensible cooling load (2) Indoor conditioned temperature (WB*1, DB) (3) Designed outdoor temperature (DB)*2 (4) Designed air flow (5) Designed external static pre

Summary of the content on the page No. 16

(Step-3) Calculation of net capacity Based on the indoor conditioned temperature (WB,DB), designed outdoor temperature (DB), and the actual air flow obtained in Step-2, obtain the gross capacity from the gross capacity tables (pages 16~35). Then, calculate the net capacity from the formula below by using the fan motor input obtained in Step-2. Net capacity (kW) = Gross capacity (kW) - Fan motor input (kW) Example: PE-8MYC OUTDOOR DB˚C INDOOR INDOOR 40.0 Condition: DB˚C WB˚C Q kW SHC kW SHF T/I

Summary of the content on the page No. 17

CAPACITY TABLES - 16 - Cooling Capacity (Standard Air Flow) PEH-5MYE-EU OUTDOOR DB ˚C INDOOR INDOOR 20.0 25.0 30.0 35.0 40.0 46.0 DB ˚C WB ˚C Q kW SHC kW SHF T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T/I kW 15 4.9 5.3 13.9 9.8 0.71 4.4 13.5 9.6 0.71 4.6 13.1 9.4 0.72 12.6 9.1 0.72 12.0 8.8 0.74 5.7 11.3 8.5 0.75 6.1 20 16 5.0 5.3 14.5 9.1 0.63 4.5 14.1 8.9 0.64 4.7 13.6 8.7 0.64 13.0 8.3 0.64 12.4 8.1 0.65 5.8 1

Summary of the content on the page No. 18

- 17 - Heating Capacity (Standard Air Flow) PEH-5MYE-EU OUTDOOR WB ˚C INDOOR -10.0 -5.0 0.0 DB ˚C Q kW T/I kW Q kW T/I kW Q kW T/I kW 3.4 15 9.2 3.1 10.7 12.4 3.7 3.4 16 9.2 3.1 10.7 12.3 3.7 3.4 17 9.1 10.7 12.3 3.8 3.1 9.1 10.6 3.5 12.3 3.8 18 3.2 9.1 10.6 3.5 12.2 3.8 19 3.2 3.5 20 9.0 3.2 10.5 12.2 3.8 3.5 21 9.0 3.2 10.5 12.2 3.9 3.5 22 8.9 10.4 12.1 3.9 3.2 8.9 10.4 3.6 12.1 3.9 23 3.2 8.8 10.3 3.6 12.0 4.0 24 3.2 3.6 25 8.8 3.2 10.3 12.0 4.1 3.6 26 8.7 3.3 10.2 11.9 4.1 3.7 27 8.7 10.2

Summary of the content on the page No. 19

- 18 - Cooling Capacity (Standard Air Flow) PE-7MYC-EU , PEH-7MYA-EU OUTDOOR DB ˚C INDOOR INDOOR 20.0 25.0 30.0 35.0 40.0 46.0 DB ˚C WB ˚C Q kW SHC kW SHF T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW SHF T/I kW 15 16.9 11.7 0.69 5.5 16.5 11.5 0.70 5.8 15.8 11.1 0.70 6.2 15.1 10.8 0.71 6.7 14.3 10.4 0.73 7.2 13.6 10.1 0.74 7.9 20 16 17.7 10.8 0.61 5.6 17.2 10.5 0.61 5.9 16.5 10.2 0.62 6.3 15.8 9.9 0.62 6.8 15 9.5 0.63

Summary of the content on the page No. 20

- 19 - Cooling Capacity (Standard Air Flow) Heating Capacity (Standard Air Flow) (Use for low ambient cooling parts) PE-7MYC-EU , PEH-7MYA-EU PEH-7MYA-EU OUTDOOR DB ˚C OUTDOOR WB ˚C INDOOR -5.0 0.0 5.0 10.0 15.0 INDOOR -10.0 -5.0 0.0 DB ˚C WB˚ C Q kW SHC kW SHF T/I kW Q kW SHC kW SHF T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW S H F T/I kW Q kW SHC kW S H F T/I kW DB ˚C Q kW T/I kW Q kW T/I kW Q kW T/I kW 15 16.9 11.5 0.68 5.0 16.7 11.3 0.68 5.1 16.5 11.9 0.72 5.1 16.1 11.0 0.68 5.3 15.7 10.8


Alternative user manuals
# User manual Category Download
1 Mitsubishi Electronics 15 User manual Air Conditioner 120
2 Mitsubishi Electronics 20-L User manual Air Conditioner 11
3 Mitsubishi Electronics 2.5KKC User manual Air Conditioner 14
4 Mitsubishi Electronics 20-MYA User manual Air Conditioner 16
5 Mitsubishi Electronics 8 User manual Air Conditioner 3
6 Mitsubishi Electronics A18AR User manual Air Conditioner 4
7 Mitsubishi Electronics CITY MULTI PKFY-PVAM-A User manual Air Conditioner 43
8 Mitsubishi Electronics CMB-P-V-F User manual Air Conditioner 12
9 Mitsubishi Electronics CITY MULTI PUHY-YMC User manual Air Conditioner 227
10 Mitsubishi Electronics A12 User manual Air Conditioner 27
11 Mitsubishi Electronics LOSSNAY LGH-100RX4-E User manual Air Conditioner 45
12 Mitsubishi Electronics LOSSNAY LGH-150RX4-E User manual Air Conditioner 18
13 Mitsubishi Electronics G-50A User manual Air Conditioner 458
14 Mitsubishi Electronics 20 PRH-5 User manual Air Conditioner 7
15 Mitsubishi Electronics LOSSNAY LGH-200RX4-E User manual Air Conditioner 16
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21