Vinotemp WINE-MATE WM-650SCU user manual

User manual for the device Vinotemp WINE-MATE WM-650SCU

Device: Vinotemp WINE-MATE WM-650SCU
Category: Refrigerator
Manufacturer: Vinotemp
Size: 0.53 MB
Added : 4/9/2013
Number of pages: 25
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Vinotemp WINE-MATE WM-650SCU. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Vinotemp WINE-MATE WM-650SCU.

For your convenience

If looking through the Vinotemp WINE-MATE WM-650SCU user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Vinotemp WINE-MATE WM-650SCU on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Vinotemp WINE-MATE WM-650SCU to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Vinotemp WINE-MATE WM-650SCU User manual - Online PDF
Advertisement
« Page 1 of 25 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Vinotemp WINE-MATE WM-650SCU but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Vinotemp WINE-MATE WM-650SCU. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



WINE-MATE Split System

Installation, Operation & Care Manual



VINO-1500SSL
VINO-2500SSL
VINO-4500SSL
VINO-6500SSL













V Vi in no ot te em mp p I In nt te er rn na at ti io on na al l C Co or rp p..

w ww ww w..w wiin ne em ma at te e..c co om m


READ AND SAVE THESE INSTRUCTIONS

Summary of the content on the page No. 2

TABLE OF CONTENTS Important Safety Information…..........................................2 Feature Description…………………………….……………..3 Cellar Construction.…………………………….……………..6 Installer’s Instruction…………….…..….……..……………..7 Temperature Control & Humidity Adjustment.………….14 Care Guide…………………………………………………….19 User’ Troubleshooting…….………………………………...20 Customer Support……………………………………………22 Warranty……………………………………………………….23

Summary of the content on the page No. 3

Important Safety Information • DO NOT USE A GROUND FAULT INTERRUPTER (GFI). • A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED. - 2 -

Summary of the content on the page No. 4

Feature Description • Wine-Mate split cooling systems VINO1500-6500SSL are designed and used to provide a cold temperature between 50~65 °F for a properly insulated wine room at a normal environment. • The wine room will maintain humidity of 50~70% RH even when the environment becomes dry and humid. These temperatures and humilities are optimized for long term storage of wine. • SSL units consist of a condensing unit and an evaporator unit, and they are connected by a liquid line and

Summary of the content on the page No. 5

Fig. 1.1 WM15-25SFCL Evaporator Unit Fig. 1.2 WM45-65SFCL Evaporator Unit NOTES: LIQUID AND SUCTION LINES MAY DIFFER FROM WHAT ARE SHOWN HERE, PLEASE CHECK ON THE UNITS FOR PROPER INSTALLATION. - 4 -

Summary of the content on the page No. 6

Fig. 1.3 WM150-450SCU Condensing Unit Fig. 1.4 WM-650SCU Condensing Unit - 5 -

Summary of the content on the page No. 7

Cellar Construction This is only a guide and shall be considered as minimum requirements. All interior walls and floors shall have a vapor barrier and a minimum of R11 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation. The vapor barrier shall be installed on the warm side of the insulation. All joints, door frames, electrical outlets or switches and any pipes or vents that go through the enclosure shall be sealed to prevent air and mo

Summary of the content on the page No. 8

Installer’s Instruction Federal law requires that WINE--MATE split cooling systems be installed by an EPA certified refrigeration technician. WINE-MATE split system is shipped as components and is ready for use only after a certified refrigeration technician has properly installed, charged and tested the system. Proper installation is critical. Vinotemp can only warrant the quality of the components. The installation and proper operation of the system must be warranted by the installe

Summary of the content on the page No. 9

1. Condensing Unit • Place the condensing units WM150-650SCU in a properly ventilated location. If it is not, heat exhausted by the condensing unit will build up and the cooling system will not operate properly. • Leave minimum 5 feet clearance for the exhaust side and leave minimum 1 foot clearance for the fresh air intake side. • Condensing unit shall be elevated to avoid possible flooding and shaded from direct sun. It shall not be exposed to temperatures higher than 110 °F or lowe

Summary of the content on the page No. 10

• High side pressure: 130 -150 psig at 75 -90 °F ambient temperatures The line sizes and refrigerant charges are listed as follows. REFRIGERATION LIQUID SUCTION DRAIN MODEL CHARGE LINES LINE LINE LINE 1/4" R134a/ VINO-1500SSL < 50 FT 3/8” OD 1/2” OD OD 15 OZ 1/4" R134a/ VINO-2500SSL < 50 FT 3/8” OD 1/2” OD OD 20 OZ 1/4" R134a/ VINO-4500SSL < 50 FT 1/2” OD 1/2” OD OD 26 OZ 1/4" R134a/ VINO-6500SSL < 50 FT 5/8” OD 1/2” OD OD 32 OZ 5. Pressure, Superheat and Subcooling Readin

Summary of the content on the page No. 11

6. Valve Operation SPINDLE BACK POSITION SPINDLE FRONT POSITION SPINDLE MIDDLE POSITION Fig. 2.2 Valve Operation Back Position: Process and manometer port closed for normal operation Front Position: Main connection to liquid or suction line closed Middle Position: All ports open for vacuum, charge and measurement 7. Electrical Wiring Fig. 2.3 VINO1500-4500SSL Electrical Wiring Diagram (VTSTAT)

Summary of the content on the page No. 12

Fig. 2.4 VINO1500-4500SSL Wiring Diagram (DIGITAL CONTROLLER) Fig. 2.5 VINO6500SSL Electrical Wiring Diagram (VTSTAT) - 11 -

Summary of the content on the page No. 13

Fig. 2.6 VINO6500SSL Electrical Wiring Diagram (DIGITAL CONTROLLER) 8. Use of the adjustable low pressure control (if applicable) Cut out = 5 psig; Cut in = 25 psig; Differential = 20 psig It may need to adjust the setting in the field to get the right cycle time. Fig. 2.7 Adjustable Pressure Control - 12 -

Summary of the content on the page No. 14

9. Condensing Unit Troubleshooting Unit not running a. Incorrect power supply a. Check for proper voltage b. Incorrect or loose wirings b. Check all wirings and connections c. Failed components c. Check start relay, start capacitor, overload protector, compressor. d. Liquid refrigerant in the compressor d. Call service for OEM information e. Low pressure switch shutting down the system e. Check for system restriction or low refrigerant

Summary of the content on the page No. 15

Temperature Control & Humidity Adjustment 1. Temperature Setting • Set the temperature at 55 °F for the optimum aging of wine • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantity of bottles, temperature setting and surrounding temperature. • Allow 24 hours to stabilize the temperature for each new temperature setting operation 2. Use of the VTSTAT controller NOTE: Use the dial number for “Medium Temp” Fig. 3.1 V

Summary of the content on the page No. 16

Dip-switch description (See detail in VSTAT instruction ) 1, 2 differential: added to the Set Point, establishes the temperature threshold, measured by the regulation probe, beyond which the compressor is activated; 3 compressor safety function: OFF - function disabled; ON - function enabled; 4 temperature display: OFF - displayed in °C; ON - displayed in °F; 5,...,8 duration of defrost/defrost termination temperature: if the defrost sensor is utilized, these dip-switches select the defro

Summary of the content on the page No. 17

If the function is enabled, the compressor is not energized for three minutes after controller power up. The function is also active in hot-gas defrost mode. 5) LED & Display Messages 1. LED off 1. Compressor and defrost deactivated 2. LED on 2. Compressor energized 3. LED blinking 0.5s on/0.5s off 3. Defrost activated 4. LED blinking 0.5s on/1.5s off 4. Sensor fault 5. Display A1 5. Regulation probe fault 6. Display A2 6. Defrost probe fault 3. Use of the Digital Controller F

Summary of the content on the page No. 18

2) Alarm Signals 2.1 Code Description 2.2 Alarm Recovery Probe alarms P1”, start a few seconds after the fault in the related probe; they automatically stop a few seconds after the probe restarts normal operation. Check connections before replacing the probe. Temperature alarms “HA”, “LA” automatically stops as soon as the temperature returns to normal value. Alarm “CA” (with i1F=PAL) recovers only by switching off and on the instrument. 3) Temperature Set-Point 3.1 How to s

Summary of the content on the page No. 19

2. The value of the set point will be displayed and the “°C” or “°F” LED starts blinking; 3. To change the Set value, push the o or n arrows within 10s. 4. To memorize the new set point value, push the SET key again or wait 10s. 4) Humidity Adjustment The parameter Fon is used to adjust the humidity in the wine cabinet. The higher value of Fon, the higher relative humidity will be. 1. Press the Set + keys for 3 sec until the “°C” or “°F” LED starts blinking. 2. Release the keys, then

Summary of the content on the page No. 20

Care Guide In general, always unplug system or disconnect power while doing care. 1. Coil Cleaning • Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months. • Unplug the system or disconnect power. • Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty. • Plug cooling system or reconnect power. 2. Moisture Removing • Remove the extra condensate if it is accumulated in the wine cellar at high ambien


Alternative user manuals
# User manual Category Download
1 Vinotemp 700 User manual Refrigerator 0
2 Vinotemp SC-1 User manual Refrigerator 10
3 Vinotemp Portofino User manual Refrigerator 2
4 Vinotemp TC32G User manual Refrigerator 0
5 Vinotemp BC-58 User manual Refrigerator 0
6 Vinotemp SC-130N User manual Refrigerator 0
7 Vinotemp VINO1500CD User manual Refrigerator 0
8 Vinotemp V5LR 2009 User manual Refrigerator 0
9 Vinotemp VinoCave Series User manual Refrigerator 6
10 Vinotemp VINO6500HZD User manual Refrigerator 0
11 Vinotemp VINO2500CD User manual Refrigerator 0
12 Vinotemp VINO1500CTED User manual Refrigerator 0
13 Vinotemp VINO4500HZD User manual Refrigerator 0
14 Vinotemp VINO2500CTED User manual Refrigerator 0
15 Vinotemp VT-12TEDi User manual Refrigerator 1
16 2JANE Surround Sound System HTS-GS1 User manual Refrigerator 4
17 3Com Phaser 7750 User manual Refrigerator 1
18 3Com iQ 10 User manual Refrigerator 0
19 3Com PowerDual iQ 10 iQ 10C User manual Refrigerator 1
20 3Com PowerDual iQ 10 iQ 10P User manual Refrigerator 2