Vinotemp WINE-MATE VINO8500DS user manual

User manual for the device Vinotemp WINE-MATE VINO8500DS

Device: Vinotemp WINE-MATE VINO8500DS
Category: Refrigerator
Manufacturer: Vinotemp
Size: 0.66 MB
Added : 12/9/2013
Number of pages: 25
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Vinotemp WINE-MATE VINO8500DS. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Vinotemp WINE-MATE VINO8500DS.

For your convenience

If looking through the Vinotemp WINE-MATE VINO8500DS user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Vinotemp WINE-MATE VINO8500DS on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Vinotemp WINE-MATE VINO8500DS to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Vinotemp WINE-MATE VINO8500DS User manual - Online PDF
Advertisement
« Page 1 of 25 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Vinotemp WINE-MATE VINO8500DS but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Vinotemp WINE-MATE VINO8500DS. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




WINE-MATE Ducted System

Installation, Operation & Care Manual


VINO4500DS
VINO6500DS
VINO8500DS











V Vi in no ot te em mp p I In nt te er rn na at ti io on na al l C Co or rp p..

w ww ww w..w wiin ne em ma at te e..c co om m

Summary of the content on the page No. 2

READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Important Safety Information…..........................................2 Feature Description…………………………….……………..3 Cellar Construction.…………………………….……………..5 Installer’s Instruction…………….…..….……..……………..6 Temperature Control & Humidity Adjustment....…………8 Service Guide………………….……………………………...13 Care Guide…………………………………………………….19 User’ Troubleshooting…….………………………………...20 Customer Support……………

Summary of the content on the page No. 3

Important Safety Information • DO NOT USE A GROUND FAULT INTERRUPTER (GFI). • A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED. - 2 -

Summary of the content on the page No. 4

Feature Description • WINE-MATE ducted system VINO4500-8500DS are designed and used to provide a cold temperature between 50~65 °F for a properly insulated wine room at a normal environment. • The wine room will maintain humidity of 50~70% RH even when the environment becomes dry and humid. These temperatures and humilities are optimized for long term storage of wine. • The DS ducted systems are designed for both outdoor and indoor installation. • Back-curved impeller fans are goo

Summary of the content on the page No. 5

The dimensions and capacities are specified as follows: Btu/h BOTTLE DIMENSION CAPACITY MODEL REFRIGERANT ELECTRICAL WEIGHT(lb) (55/90°F) L”xH”xW” (55/75°F) CFM VINO- 1000 4500 45X23 X34 4500/380 R134a 115V-60HZ-8A 140 4500DS cu ft bottles VINO- 1500 6500 45X23 X34 6500/490 R134a 115V-60HZ-14A 170 6500DS cu ft bottles VINO- 2000 8500 45X25 X34 8500/750 R134a 115V-60HZ-17A 220 8500DS cu ft bottles Fig. 1.2 VINO4500- 8500DS DIMENSIONS

Summary of the content on the page No. 6

Cellar Construction This is only a guide and shall be considered as minimum requirements. All interior walls and floors shall have a vapor barrier and a minimum of R11 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation. The vapor barrier shall be installed on the warm side of the insulation. All joints, door frames, electrical outlets or switches and any pipes or vents that go through the enclosure shall be sealed to prevent air and mo

Summary of the content on the page No. 7

Installer’s Instruction Federal law requires that WINE-MATE ducted cooling systems be installed by an EPA certified refrigeration technician. WINE-MATE ducted system is shipped ready for use only after a certified refrigeration technician has properly installed the system. Proper installation is critical. Vinotemp can only warrant the quality of the components. The installation and proper operation of the system must be warranted by the installer. Installation of the system must be do

Summary of the content on the page No. 8

1. Location • Place the unit in a properly ventilated location. If it is not, heat exhausted by the condensing unit will build up and the cooling system will not operate properly. • Leave minimum 5 feet clearance for hot air exhaust and leave minimum 1 foot clearance for the fresh air intake. • Air flow from the cold air supply shall be unobstructed for at least 1 foot. • Cooling unit shall be elevated to avoid possible flooding and shaded from direct sun. It shall not be exposed to tem

Summary of the content on the page No. 9

Temperature Control & Humidity Adjustment 1. Temperature Setting • Set the temperature at 55 °F for the optimum aging of wine • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantity of bottles, temperature setting and surrounding temperature. • Allow 24 hours to stabilize the temperature for each new temperature setting operation 2. Use of the VTSTAT electronic temperature controller Fig. 3.1 VTSTAT Fig. 3.2 D

Summary of the content on the page No. 10

Dip-switch description (See detail in VSTAT instruction) 1, 2 differential: added to the Set Point, establishes the temperature threshold, measured by the regulation probe, beyond which the compressor is activated; 3 compressor safety function: OFF - function disabled; ON - function enabled; 4 temperature display: OFF - displayed in °C; ON - displayed in °F; 5,...,8 duration of defrost/defrost termination temperature: if the defrost sensor is utilized, these dip-switches select the defros

Summary of the content on the page No. 11

If the function is enabled, the compressor is not energized for three minutes after controller power up. The function is also active in hot-gas defrost mode. 5) LED & Display Messages 1. LED off 1. Compressor and defrost deactivated 2. LED on 2. Compressor energized 3. LED blinking 0.5s on/0.5s off 3. Defrost activated 4. LED blinking 0.5s on/1.5s off 4. Sensor fault 5. Display A1 5. Regulation probe fault 6. Display A2 6. Defrost probe fault 3. Use of the Digital Controller

Summary of the content on the page No. 12

2) Alarm Signals 2.1 Code Description 2.2 Alarm Recovery Probe alarms P1”, start a few seconds after the fault in the related probe; they automatically stop a few seconds after the probe restarts normal operation. Check connections before replacing the probe. Temperature alarms “HA”, “LA” automatically stops as soon as the temperature returns to normal value. Alarm “CA” (with i1F=PAL) recovers only by switching off and on the instrument. 3) Temperature Set-Point 3.1 How to

Summary of the content on the page No. 13

2. The value of the set point will be displayed and the “°C” or “°F” LED starts blinking; 3. To change the Set value, push the o or n arrows within 10s. 4. To memorize the new set point value, push the SET key again or wait 10s. 4) Humidity Adjustment The parameter Fon is used to adjust the humidity in the wine cabinet. The higher value of Fon, the higher relative humidity will be. 1. Press the Set + keys for 3 sec until the “°C” or “°F” LED starts blinking. 2. Release the keys, then

Summary of the content on the page No. 14

Service Guide 1. Refrigeration Piping and Charge • The subcooling at the condensing unit shall be around 10°F. The charge may be complete when there are no more bubbles forming in the sight glass. • The evaporator’s constant pressure expansion valve is set around 38- 40°F at factory. This pressure setting gives a dew point to maintain the humidity for storing wine. • The superheat at the evaporator unit shall be around 9-18°F under low and high load at 75°F ambient temperature. •

Summary of the content on the page No. 15

k. Low suction pressure and low to normal head pressure k. Evaporator restricted High superheat and normal to high subcooling l. Low suction pressure and normal head pressure l. Expansion valve restricted High superheat and normal subcooling m. Low suction pressure and high head pressure m. Both evaporator and condenser High superheat and high subcooling restricted n. Low suction pressure and high head pressure n. Liquid line restricted before High superheat a

Summary of the content on the page No. 16

4. Electrical Wiring Fig. 4.2 VINO4500DS Electrical Wiring Diagram (VTSTAT) Fig. 4.3 VINO4500DS Electrical Wiring Diagram (DIGITAL CONTROLLER) - 15 -

Summary of the content on the page No. 17

Fig. 4.4 VINO6500DS Electrical Wiring Diagram (VTSTAT) Fig. 4.5 VINO6500DS Electrical Wiring Diagram (DIGITAL CONTROLLER) - 16 -

Summary of the content on the page No. 18

Fig. 4.6 VINO8500DS Electrical Wiring Diagram (VTSTAT, UJ6220Z) Fig. 4.7 VINO8500DS Wiring Diagram (DIGITAL CONTROLLER, UJ6220Z) - 17 -

Summary of the content on the page No. 19

5. Use of the adjustable low pressure control (if applicable) Cut out = 5 psig; Cut in = 25 psig; Differential = 20 psig Fig. 4.8 Adjustable Low Pressure Control 6. Condensing Unit Troubleshooting Unit not running a. Incorrect power supply a. Check for proper voltage b. Incorrect or loose wirings b. Check all wirings and connections c. Failed components c. Check start relay, start capacitor, overload protector, compressor. d. Liquid refrigerant in the compressor d. Call serv

Summary of the content on the page No. 20

Care Guide In general, always unplug system or disconnect power while doing care. 1. Coil Cleaning • Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months. • Unplug the system or disconnect power. • Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty. • Plug cooling system or reconnect power. 2. Moisture Removing • Remove the extra condensate if it is accumulated in the wine cellar at high ambien


Alternative user manuals
# User manual Category Download
1 Vinotemp 700 User manual Refrigerator 0
2 Vinotemp SC-1 User manual Refrigerator 10
3 Vinotemp Portofino User manual Refrigerator 2
4 Vinotemp TC32G User manual Refrigerator 0
5 Vinotemp BC-58 User manual Refrigerator 0
6 Vinotemp SC-130N User manual Refrigerator 0
7 Vinotemp VINO1500CD User manual Refrigerator 0
8 Vinotemp V5LR 2009 User manual Refrigerator 0
9 Vinotemp VinoCave Series User manual Refrigerator 6
10 Vinotemp VINO6500HZD User manual Refrigerator 0
11 Vinotemp VINO2500CD User manual Refrigerator 0
12 Vinotemp VINO1500CTED User manual Refrigerator 0
13 Vinotemp VINO4500HZD User manual Refrigerator 0
14 Vinotemp VINO2500CTED User manual Refrigerator 0
15 Vinotemp VT-12TEDi User manual Refrigerator 1
16 2JANE Surround Sound System HTS-GS1 User manual Refrigerator 4
17 3Com Phaser 7750 User manual Refrigerator 1
18 3Com iQ 10 User manual Refrigerator 0
19 3Com PowerDual iQ 10 iQ 10C User manual Refrigerator 1
20 3Com PowerDual iQ 10 iQ 10P User manual Refrigerator 2