Summary of the content on the page No. 1
Quality Refrigeration
OWNER’S MANUAL
Instructions for the installation
and maintenance of most Traulsen models as well as
instructions to operate the following special models:
Blast Freezer Models
RBF134HUT-FHS (formerly RIF134HUTBF) & RBF234HUT-FHS (formerly RIF234HUTBF)
Fish File Models
RFS126NUT, RFS226NUT & RFC232WSC
This Traulsen unit is built to our highest quality standards. We build our refrigerators, freezers and heated
cabinets this way as a matter of pride. This philosophy has made
Summary of the content on the page No. 2
TABLE OF CONTENTS I. THE SERIAL TAG Page 1 VII. FISH FILE MODELS II. RECEIPT INSPECTION Page 2 a-Fish File Application Page 6 III. INSTALLATION b-Special Installation Note Page 6 a-Location Page 2 c-Drawer Pans Page 6 b-Packaging Page 2 d-Product Loading Page 6 c-Installing Legs or Casters Page 2 e-Cleaning Page 6 d-Shelf Pins Page 2 VIII. BLAST FREEZER MODELS e-Roll-In Model Installation Page 3 a-Blast Freezer Application Page 7 f-Installing The Condensate Evaporator Page 3 b-Special Installati
Summary of the content on the page No. 3
II. RECEIPT INSPECTION III. INSTALLATION (continued) All Traulsen products are factory tested for perfor- III. c - INSTALLING LEGS OR CASTERS: mance and are free from defects when shipped. The 6” high stainless steel legs are supplied standard for utmost care has been taken in crating this product to all Traulsen reach-in and pass-thru units. Casters in protect against damage in transit. All interior fittings lieu of legs are available as an optional accessory for have been carefully secured
Summary of the content on the page No. 4
III. INSTALLATION (continued) III. f - INSTALLING THE CONDENSATE EVAP (cont’d): III. e - ROLL-IN MODEL INSTALLATION: holes on the exterior bottom towards the rear of the Roll-In cabinets set on the floor require the floor area cabinet. Then, using the four (4) screws provided, at- to be flat and level. In addition, after the cabinet is set tach the mounting rails to the cabinet bottom (the end in place, sealant should be used around the perimeter flange is to be up and be facing towards the c
Summary of the content on the page No. 5
III. INSTALLATION (continued) V. CARE & MAINTENANCE (cont’d) IV. a - CLEANING THE CONDENSER (cont’d): III. i - POWER SUPPLY: two screws located on both sides at the bottom of the The supply voltage should be checked prior to con- louver assembly (see figure 6). Once the screws are nection to be certain that proper voltage for the cabi- removed, the panel can be pivoted upwards allowing net wiring is available (refer to the serial tag to deter- full access to the front facing condenser (see figu
Summary of the content on the page No. 6
IV. CARE & MAINTENANCE (cont’d) V. MISC. OPERATIONS V. a - ADJUSTING THE SHELVES: IV. b - HINGE REPLACEMENT: For shelves mounted on pins, first select the desired door units, the top hinge(s) contains a microswitch location and remove the white plastic covers in the for controlling the interior lighting. interior back and sides by rotating them counter-clock- wise. Remove the shelf pins by rotating them counter- To reassemble the hinge reverse the previous proce- clockwise. Install the pins in
Summary of the content on the page No. 7
VII. SPECIALTY PRODUCTS - FISH FILE MODELS VII. e - CLEANING: VII. a - FISH FILE APPLICATION: This unit should be cleaned on a daily basis. The en- Traulsen fish file models are specifically designed for tire interior should be sprayed with water. Both drawer the storage of fresh fish or poultry in a moist refriger- pans and inserts should be thoroughly cleaned and ated environment, packed in crushed ice, thereby pre- sanitized each day. venting dehydration and bacteria growth. For best re-
Summary of the content on the page No. 8
VIII. SPECIALTY PRODUCTS - BLAST FREEZER MODELS VIII. a - BLAST FREEZER APPLICATION: The roll-in blast freezer models were specifically de- The Blast Freezer Control signed for batch processing, where quick freezing of Temperature Display cooked product is required to help prolong shelf life. Traulsen VIII. b - SPECIAL INSTALLATION NOTE: DIGITRAUL Installation should be performed as typical with any other model, see “Section III.” However, a blast freezer DEFOGGER also requires provision of a f
Summary of the content on the page No. 9
IX. STAINLESS STEEL OVERVIEW TROUBLE IX. a - INTRODUCTION: IX. c - UNDERSTANDING THE CAUSES OF CORROSION: Most Traulsen models are constructed with a high quality contain acids which may damage the protective layer of 430 series, 20 gauge stainless steel exterior finish (front, stainless steel. All food and beverage spills should be sides and doors). The interior finish on these same mod- cleaned up promptly to avoid possible stains and corro- els are constructed using 300 series stainless ste
Summary of the content on the page No. 10
X. CARE OF STAINLESS STEEL (cont’d) XI. CORROSION REMEDIES XI. a - DEALING WITH RUST AFTER THE FACT (cont’d): X. c - CLEANING SUMMARY - DO’S & DONT’S: STEP TWO - Once the rust is removed, clean the affected To summarize the proper cleaning of Traulsen refrigeration area thoroughly with a stainless steel cleaner (see sections products, always follow the below guidelines. II. a & b). DO use only cleaning products designed for STEP THREE - Apply a preservative polish, such as “Sheila stainless stee
Summary of the content on the page No. 11
XI. TROUBLE SHOOTING GUIDE FIND YOUR PROBLEM HERE REMEDY 1. Condensing unit fails to start. a. Check if cord & plug has been disconnected. 2. Condensing unit operates for a. Are doors closing properly? prolonged periods or continuously. b. Dirty condenser or filter. Clean properly. c. Evaporator coil iced. Needs to defrost. d. Shortage of refrigerant, call service. 3. Food compartment is too warm. a. Check door(s) and gasket(s) for proper seal b. Perhaps a large qua
Summary of the content on the page No. 12
XII. WARRANTY INFORMATION STANDARD DOMESTIC WARRANTY TRAULSEN & CO., INC. warrants new equipment to the original purchaser, when installed within the United States against defective material and workmanship for one (1) year from the date of original installation. Under this warranty, TRAULSEN & CO., INC. will repair or replace, at its option, including service and labor, all parts found to be defective and subject to this warranty. The compressor part is warranted for an additional four (4) year