Trane RTAA 70-125 TON user manual

User manual for the device Trane RTAA 70-125 TON

Device: Trane RTAA 70-125 TON
Category: Refrigerator
Manufacturer: Trane
Size: 1.84 MB
Added : 9/17/2014
Number of pages: 88
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Trane RTAA 70-125 TON. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Trane RTAA 70-125 TON.

For your convenience

If looking through the Trane RTAA 70-125 TON user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Trane RTAA 70-125 TON on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Trane RTAA 70-125 TON to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Trane RTAA 70-125 TON User manual - Online PDF
Advertisement
« Page 1 of 88 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Trane RTAA 70-125 TON but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Trane RTAA 70-125 TON. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Diagnostic
Troubleshooting
Repair
®
Series R
70-125 Ton Air-Cooled and Water-Cooled
Rotary Liquid Chillers
Model
RTAA 70-125 Ton
RTWA 70-125 Ton
RTUA 70-125 Ton
August 2005 RLC-SVD03A-EN
© American Standard Inc. 2005

Summary of the content on the page No. 2

NOTICE: Warnings and Cautions appear at appropriate sections through- out this literature. Read these carefully.  WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.  CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. CAUTION: Indicates a situation that may result in equipment or property- damage only ac

Summary of the content on the page No. 3

Contents General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Service Philosophy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 System Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 System Level Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Interprocessor Communications . . . . . . . . . . .

Summary of the content on the page No. 4

General Information The Unit Control Modules (UCMs) described in this troubleshooting guide provide a microprocessor based refrigeration control system, intended for use with Trane 70-125 ton helical rotor chillers. Six types of modules are used, and throughout this publication will be referred to by their abbreviations or their Line Wiring Drawing Designations, see Table 1. Table 1 Unit Control Module Designations Line Drawing Controller Name Abbrev. Designation Chiller Module CPM 1U2 Optio

Summary of the content on the page No. 5

General Information System Description The CPM is the master module and coordinates operation of the entire system. One is used per chiller. The MCSP is a compressor protection module with one being used for each of the compressors in the chiller. The EXV is the expansion valve controller module which controls two Electronic Expansion Valves. There is one valve on each of the two refrigeration circuits. The CLD is a two line, 40 character alphanumeric interface to the system. It allows the

Summary of the content on the page No. 6

General Information High Pressure Cutout Switch Low Pressure Cutout Switch Variable Speed Fan Drive Motor Temperature Thermostats Slide Valve Load/Unload Solenoids Step Load Solenoid Valve Chiller Module (CPM) IU1 The CPM module performs machine (chiller) level control and protection functions. Only one CPM is present in the chiller control system. The CPM acts as the master controller to the other modules, running top level machine control algorithms, initiating and controlling all inte

Summary of the content on the page No. 7

General Information Real time data for temperatures, diagnostics and control algorithms etc. are made available to the CPM and the other modules for display and for input to higher level functions. See Electronic Expansion Valve Module (EXV) (1U3) on page 58 for details. Options Module (CSR) 1U2 The CSR module is an optional part of the system and employs communica- tions circuits for interface to Trane Building Automation Systems, done through 1C17. The CSR also provides inputs for hard wir

Summary of the content on the page No. 8

Interprocessor Communications The respective modules communicate with each other via an InterProcessor Communication link (IPC). The IPC allows the modules to work in a coordi- nated manner with the CPM directing overall chiller operation while each module handles specific subfunctions. This IPC link is integral and necessary to the operation of the Unit Controls and should not be confused with the Optional ICS (Integrated Comfort System) communication. In the IPC communication protocol sche

Summary of the content on the page No. 9

Interprocessor Communication from the Options Module. When some problem exists with the IPC link or a module fails, it is not uncommon for more than one of these IPC diagnostics to be displayed. Note that only those diagnostics that are indicated to be active currently exist. All other historic diagnostics should be disregarded for the purpose of the following troubleshooting discussion. See RTAA-IOM-4 for a complete listing of diagnostics. Troubleshooting Modules Using IPC Diagnostics  WA

Summary of the content on the page No. 10

Interprocessor Communication Figure 1 IPC Link Order For 70-125 Ton RTAA 10 RLC-SVD03A-EN

Summary of the content on the page No. 11

Interprocessor Communication . Table 2 IPC Address Dip Switch (SW1) Settings for MCSP an EXV Modules MODULE DESIG. CONTROLLING DIP SWITCH SETTING SW1-1 SW1-2 MCSP “A” 1U4 COMPRESSOR A OFF OFF MCSP “B” 1U5 COMPRESSOR B OFF ON EXV 1U3 CKTS. 1 & 2 OFF OFF 3. Loss of power to a module: Generally a power loss to a particular module will only affect communica- tions with that module. The module can usually be identified by analysis of the IPC diagnostics. (When the display is blank, check power at th

Summary of the content on the page No. 12

Interprocessor Communication Figure 3 IPC Jumper For Bypassing Modules (to be inserted into MTA connector in place of module) 5. Improper connections to terminal J2: Jack J2, present on all modules except CLD, should have no connections. This input is for manufacturing test purposes only and any connections, shorts, etc. will potentially cause the module to not respond, respond to the wrong address, or (in the case of the CPM) fail to initiate any commu- nications and thus fail

Summary of the content on the page No. 13

Interprocessor Communication 3. Determine which modules are still talking. Wiring up to these is likely to be OK. 4. Try disconnecting the link or jumping out modules in the link at various places (use Figure 1). Reset the diagnostics and note which diagnostics reappear. Here are some examples of IPC diagnostics: Diagnostics present: Chiller Mod Indicating EXV Mod Communications Cprsr A Indicating EXV Mod Communications Cprsr B Indicating EXV Mod Communications The CPM and both MCSP modules

Summary of the content on the page No. 14

Interprocessor Communication The CPM has detected loss of communications with MCSP A, MCSP B, and EXV. Suspect an open early in the IPC link between the CPM and MCSP B. There are a large number of possible combinations of diagnostics. One must deduce what is causing the problem using all available information. If the CLD Comm link to the CPM is broken, the message is: No Communication, Data Not Valid 14 RLC-SVD03A-EN

Summary of the content on the page No. 15

Temperature Sensor Checkout With the exception of the thermostats located in the motor windings of the screw compressors, all the temperature sensors used on the UCMs are negative temperature coefficient (NTC) thermistors. The thermistors employed all have a base resistance of 10 Kohms at 77F (25C) and display a decreasing resistance with an increasing temperature. The UCMs “read” the temperature by measuring the voltage developed across the thermistors in a voltage divider arrangement wit

Summary of the content on the page No. 16

Temperature Sensor Checkout 4. Again measure the temperature at the sensor with an accurate thermom- eter; record the temperature reading observed. 5. Remove the sensor leads from the terminal strip or unplug the respective MTA. Measure the resistance of the sensor directly or probe the MTA with a digital volt-ohmmeter. Record the resistance observed. 6. Next, with the sensor still disconnected from the module, check the resistance from each of the sensor leads to the control panel chassis.

Summary of the content on the page No. 17

Temperature Sensor Checkout . Table 3 Sensor Conversion Data: Outdoor Air (6RT3), Entering and Leaving Evap Water Temp Matched Pairs (6RT7, 6RT8), and Saturated Evap and Comp Suction Refrigeration Temp (6RT9, 3B1RT5; 6RT10, 4B1RT6) Actual Actual Thermistor Actual Actual Thermistor Actual Actual Thermistor Temp. Resistance Voltage Temp. Resistance Voltage Temp. Resistance Voltage (F) (Ohms) (Volts DC) (F) (Ohms) (Volts DC) (F) (Ohms) (Volts DC) -20.0 170040.3 4.448 30.0 34838.9 3.120 80.0 9297.5

Summary of the content on the page No. 18

Temperature Sensor Checkout Table 4 Sensor Conversion Data: Saturated Condenser and Entering Oil Temperature Matched Pairs (6RT12, 3B1RT1; 6RT13, 4B1RT2) Actual Actual Thermistor Actual Actual Thermistor Actual Actual Thermistor Temp. Resistance Voltage Temp. Resistance Voltage Temp. Resistance Voltage (F) (Ohms) (Volts DC) (F) (Ohms) (Volts DC) (F) (Ohms) (Volts DC) 0.0 87510.3 4.651 50.0 19955.0 3.765 100.0 5824.3 2.356 1.0 84745.9 4.641 51.0 19427.9 3.740 101.0 5694.2 2.327 2.0 82072.1 4.630

Summary of the content on the page No. 19

Compressor Operation This feature is called the Auto Lead/Lag and can be found in the Service Settings Group, under the “Balanced CPRSR Starts and Hours” menu. When this function is disabled, the UCM always starts compressor “A” first. When this function is enabled, the following occurs: The UCM equalizes operating starts and hours. This will cause the compressor with the least amount of starts to be started first. When a compressor starts, it is always started unloaded. When a compressor i

Summary of the content on the page No. 20

Compressor Start/Stop To start a compressor after either a “normal' shutdown, a Diagnostic reset, or power-on-reset, the following sequence will occur: 1. On a call for a compressor, the Restart Inhibit Timer will time out, if any time remains. 2. The EXV is positioned to the initial closed start position. At the same time, the unload solenoid is energized and the load solenoid is de-ener- gized. Timing is determined by the time required to position the EXV 3. After the EXV is positioned: � t


Alternative user manuals
# User manual Category Download
1 Trane 22-5214-03 User manual Refrigerator 1
2 Trane CCAF User manual Refrigerator 2
3 Trane CG-PRC007-EN User manual Refrigerator 17
4 Trane Centrifugal Water Chillers CVGF User manual Refrigerator 94
5 Trane RTUA 70-125 TON User manual Refrigerator 17
6 Trane CGWF User manual Refrigerator 6
7 Trane RTWA 70-125 TON User manual Refrigerator 110
8 Trane 22-5214-03 User manual Refrigerator 1
9 2JANE Surround Sound System HTS-GS1 User manual Refrigerator 4
10 3Com Phaser 7750 User manual Refrigerator 1
11 3Com iQ 10 User manual Refrigerator 0
12 3Com PowerDual iQ 10 iQ 10C User manual Refrigerator 1
13 3Com PowerDual iQ 10 iQ 10P User manual Refrigerator 2
14 3Com Dell D-Family Battery Charger CHRG01L User manual Refrigerator 0
15 3Com PowerDual iQ 10 iQ 10PC User manual Refrigerator 0