Category: Air Conditioner
Manufacturer: Mitsubishi Electronics
Size: 0.62 MB
Added : 7/9/2013
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Mitsubishi Electronics Mr. Slim PLA-A-AA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Mitsubishi Electronics Mr. Slim PLA-A-AA.

For your convenience

If looking through the Mitsubishi Electronics Mr. Slim PLA-A-AA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Mitsubishi Electronics Mr. Slim PLA-A-AA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Mitsubishi Electronics Mr. Slim PLA-A-AA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Mitsubishi Electronics Mr. Slim PLA-A-AA User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Mitsubishi Electronics Mr. Slim PLA-A-AA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Mitsubishi Electronics Mr. Slim PLA-A-AA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Air-Conditioners
PLA-A·AA
Deutsch
Nederlands
Español
Italiano
ÏÏËÓÈο
Português
Dansk
Svenska
INSTALLATION MANUAL FOR INSTALLER
English
For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing
the air-conditioner unit.
PARA EL INSTALADOR
MANUAL DE INSTALACIÓN
Español
Para un uso correcto y seguro, lea detalladamente este manual y el manual de instalación de la unidad exterior
antes de instalar la unidad de aire acondicionado.
BG79U795H01_c

Summary of the content on the page No. 2

Contents 1. Safety precautions ................................................................................... 2 6. Electrical work .......................................................................................... 7 2. Installation location .................................................................................. 3 7. Test run .................................................................................................. 12 3. Installing the indoor unit .................

Summary of the content on the page No. 3

2. Installation location Refer to the outdoor unit installation manual. 3. Installing the indoor unit Caution: Install the indoor unit at least 2.4 m, 8 ft above floor or grade level. 3.1. Check the indoor unit accessories (Fig. 3-1) 1 2 The indoor unit should be supplied with the following accessories. Accessory name Q’ty 1 Installation template 1 2 Washers (with insulation) 4 3 4 Washers (without insulation) 4 3 Pipe cover (for refrigerant piping joint) Small diameter 1 Large diameter 1 4 Ban

Summary of the content on the page No. 4

23-13/16 3. Installing the indoor unit 3.4. Branch duct hole and fresh air intake hole (Fig. 3-4) (inch) C At the time of installation, use the duct holes (cut out) located at the positions shown K in following diagram, as and when required. L • A fresh air intake hole for the optional multi function casement can also be made. M 120° Note: B A A The figure marked with * in the drawing represent the dimensions of the main unit excluding those of the optional multi function casement. N When instal

Summary of the content on the page No. 5

R1/64 to R1/32 4. Installing the refrigerant piping 4.1. Precautions 4.1.1. For devices that use R410A refrigerant • Use ester oil, ether oil, alkylbenzene oil (small amount) as the refrigeration oil applied to the flared sections. • Use C1220 copper phosphorus, for copper and copper alloy seamless pipes, to connect the refrigerant pipes. Use refrigerant pipes with the thicknesses specified in the table to the below. Make sure the insides of the pipes are clean and do not contain any harmful con

Summary of the content on the page No. 6

4. Installing the refrigerant piping A Refrigerant pipe and insulating ma- 4.3. Indoor unit (Fig. 4-2) terial Heat insulation for refrigerant pipes: A B Pipe cover (large) 1 Wrap the enclosed large-sized pipe cover around the gas pipe, making sure that C Pipe cover (small) the end of the pipe cover touches the side of the unit. D Refrigerant pipe (gas) 2 Wrap the enclosed small-sized pipe cover around the liquid pipe, making sure E Refrigerant pipe (liquid) that the end of the pipe cover touches

Summary of the content on the page No. 7

6. Electrical work G 6.1. Indoor unit (Fig. 6-1) F A 1. Remove the two electrical wiring service panels. B C 2. Wire the power cable and control cable separately through the respective wiring S1 S2 S3 L1 L2 GR entries given in the diagram. • Do not allow slackening of the terminal screws. • Leave excess cable so that the electrical box can be suspended below the unit during servicing. (Approx. 50 to 100 mm, 2 to 4 inch) E A Entry for control cable 12 D B Entry for power C Clamp H D Service panel

Summary of the content on the page No. 8

CND BLUE YELLOW YELLOW BLUE CND BLUE YELLOW BLUE YELLOW 6. Electrical work 6.1.2. Separate indoor unit/outdoor unit power supplies (A-control application) The following connection patterns are available. The outdoor unit power supply patterns vary on models. 1:1 System A Outdoor unit power supply B Wiring circuit breaker or isolating switch C Outdoor unit F C D Indoor unit/outdoor unit connecting cords L1 L1 E Remote controller L2 G L2 A B B F Indoor unit GR GR S1 S1 G Indoor unit power supply S

Summary of the content on the page No. 9

CND CND BLUE YELLOW BLUE BLACK YELLOW BLUE BLACK BLACK BLUE YELLOW BLUE BLACK BLUE YELLOW BLUE BLUE 6. Electrical work 6.1.3. K-control application The following connection patterns are available. The outdoor unit power supply patterns vary on models. 1:1 System A Outdoor unit power supply B Wiring circuit breaker or isolating switch C Outdoor unit F G C C D Indoor unit/outdoor unit connecting cords L1 L1 L1 L1 E Remote controller L2 H B L2 L2 H B

Summary of the content on the page No. 10

6. Electrical work B 6.2. Remote controller A 6.2.1. For wired remote controller (inch) 1) Installing procedures (1) Select an installing position for the remote controller. (Fig. 6-2) The temperature sensors are located on both remote controller and indoor unit. 1-3/16 1-3/16 s Procure the following parts locally: D C 1-37/64 A Two piece switch box E Thin copper conduit tube Lock nuts and bushings F A Remote controller profile I G B Required clearances surrounding the remote controller C H C In

Summary of the content on the page No. 11

6. Electrical work 4) Assigning a remote controller to each unit (Fig. 6-7) Each unit can be operated only by the assigned remote controller. Make sure each pair of an indoor unit PC board and a remote controller is assigned A MODEL SELECT to the same pair No. 5) Wireless remote controller pair number setting operation 1 Press the SET button with something sharp at the end. ON/OFF TEMP Start this operation from the status of remote controller display turned off. blinks and Model No. is lighted

Summary of the content on the page No. 12

6. Electrical work Function table Select unit number 00 Mode Settings Mode no. Setting no. Initial setting setting Power failure automatic recovery Not available 1 01 Available *1 2 Indoor temperature detecting Indoor unit operating average 1 Set by indoor unit’s remote controller 02 2 Remote controller’s internal sensor 3 LOSSNAY connectivity Not Supported 1 Supported (indoor unit is not equipped with outdoor-air intake) 03 2 Supported (indoor unit is equipped with outdoor-air intake) 3 Power v

Summary of the content on the page No. 13

7. Test run 7.2.3. Using SW4 in outdoor unit Refer to the outdoor unit installation manual. B E D A B 7.3. Self-check 7.3.1. Wired remote controller (Fig. 7-3) 1 Turn on the power. CHECK 2 Press the [CHECK] button twice. 3 Set refrigerant address with [TEMP] button if system control is used. ERROR CODE 4 Press the [ON/OFF] button to stop the self-check. TEMP. ON/OFF ON/OFF TEMP A CHECK button C MENU ON/OFF FILTER B Refrigerant address 4 BACK MONITOR/SET DAY CHECK TEST C TEMP. button PAR-21MAA

Summary of the content on the page No. 14

7. Test run [Output pattern B] Errors detected by unit other than indoor unit (outdoor unit, etc.) Wired remote Wireless remote controller controller Beeper sounds/OPERATION Symptom Remark INDICATOR lamp flashes Check code (Number of times) 1 E9 Indoor/outdoor unit communication error (Transmitting error) (Outdoor unit) 2 UP Compressor overcurrent interruption 3 U3, U4 Open/short of outdoor unit thermistors 4 UF Compressor overcurrent interruption (When compressor locked) 5 U2 Abnormal high disc

Summary of the content on the page No. 15

8. System control Refer to the outdoor unit installation manual. 9. Installing the grille 9.1. Checking the contents (Fig. 9-1) 1 • This kit contains this manual and the following parts. Accessory name Q’ty Remark 2 3 1 Grille 1 950 × 950 (mm), 37 - 3/8 × 37 - 3/8 inch 2 Screw with captive washer 4 M5 × 0.8 × 25 3 Gauge 1 (Divided into four parts) 4 Fastener 2 4 5 5 Screw 4 4 × 8 6 Wired remote controller 1 for PLP-42AAMD 6 Fig. 9-1 A 9.2. Preparing to attach the grille (Fig. 9-2) • With the gau

Summary of the content on the page No. 16

9. Installing the grille D A 9.4.2. Temporary installation of the grille (Fig. 9-6) B • Temporarily secure the grille using the bell shaped holes by aligning the corner drain pipe area of the main unit with the two holes of the grille that are marked A C and B. A C * Make sure that the lead wiring of the grille does not get pinched between the grille and the main unit. D A Main unit B Detailed diagram of installed screw with washer 2. C Corner drain pipe area D Screw with washer 2 (for temporary

Summary of the content on the page No. 17

9. Installing the grille G 9.8. Installing the intake grille (Fig. 9-11) Note: C E D A When reinstalling the corner panels (each with a safety wire attached), connect the other end of each safety wire to the grille using a screw (4 pcs, 4 ××××× 8) as shown in the illustration. H * If the corner panels are not attached, they may fall off while the unit is operating. B • Perform the procedure that is described in “9.2. Preparing to attach the grille” in reverse order to install the intake grille a

Summary of the content on the page No. 18

This product is designed and intended for use in the residential, commercial and light-industrial environment. Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Printed in JAPAN BG79U795H01 BG79U795H01_cover 2 05.10.19, 14:01


Alternative user manuals
# User manual Category Download
1 Mitsubishi Electronics 15 User manual Air Conditioner 120
2 Mitsubishi Electronics 20-L User manual Air Conditioner 11
3 Mitsubishi Electronics 2.5KKC User manual Air Conditioner 14
4 Mitsubishi Electronics 20-MYA User manual Air Conditioner 16
5 Mitsubishi Electronics 8 User manual Air Conditioner 3
6 Mitsubishi Electronics A18AR User manual Air Conditioner 4
7 Mitsubishi Electronics CITY MULTI PKFY-PVAM-A User manual Air Conditioner 43
8 Mitsubishi Electronics CMB-P-V-F User manual Air Conditioner 12
9 Mitsubishi Electronics CITY MULTI PUHY-YMC User manual Air Conditioner 227
10 Mitsubishi Electronics A12 User manual Air Conditioner 27
11 Mitsubishi Electronics LOSSNAY LGH-100RX4-E User manual Air Conditioner 45
12 Mitsubishi Electronics LOSSNAY LGH-150RX4-E User manual Air Conditioner 18
13 Mitsubishi Electronics G-50A User manual Air Conditioner 458
14 Mitsubishi Electronics 20 PRH-5 User manual Air Conditioner 7
15 Mitsubishi Electronics LOSSNAY LGH-200RX4-E User manual Air Conditioner 16