MAC Tools ACL2500 user manual

User manual for the device MAC Tools ACL2500

Device: MAC Tools ACL2500
Category: Refrigerator
Manufacturer: MAC Tools
Size: 0.08 MB
Added : 3/9/2013
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for MAC Tools ACL2500. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with MAC Tools ACL2500.

For your convenience

If looking through the MAC Tools ACL2500 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual MAC Tools ACL2500 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual MAC Tools ACL2500 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
MAC Tools ACL2500 User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual MAC Tools ACL2500 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to MAC Tools ACL2500. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

ACL2500
Refrigerant
Leak Detector
Owner’s Manual

Summary of the content on the page No. 2

THIS MODEL IS: DESIGN CERTIFIED BY MET LABORATORIES, INC. TO MEET SAE J1627 FOR R134a, R12 AND R22. CLASS 1 DIVISION 2 GROUPS C & D HAZARDOUS LOCATIONS HAND HELD GAS DETECTOR CLASSIFIED BY C US UNDERWRITERS LABORATORIES, INC.® AS TO FIRE ELECTRICAL SHOCK AND EXPLOSION HAZARDS ONLY. READ OWNERS MANUAL BE- FORE OPERATING. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,DE-ENER- GIZE UNIT BEFORE REPLAC- ING SENSING TIP OR SERVIC- ING UNIT, USE ONLY WITH 1.5V ALKALINE BATTERIES, SIZE C.

Summary of the content on the page No. 3

TABLE OF CONTENTS General Information......................................................2 Features........................................................................2 Parts & Controls ..........................................................3 Getting Started..............................................................4 Installing Batteries ..................................................4 Operating Features ......................................................4 Battery Indicator ...

Summary of the content on the page No. 4

GENERAL INFORMATION Thank you for purchasing the MAC TOOLS Refeigerant Leak Detector. The ACL2500 is the most stable and sensitive negative corona Leak Detector ever made. An advanced microprocessor is the heart of this unit. Its Digital Signal Processing permits better management of the circuitry and sensing tip signal than ever before possible. Additionally, the number of components used in the circuit is reduced near- ly 40%, increasing reliability and performance. The microprocessor monitors

Summary of the content on the page No. 5

PARTS & CONTROLS KEYPAD 10 9 6 7 5 8 3 4 7 6 8 5 3 4 2 1 1. Sensing Tip 2. Tip Protector 3. Power On/OFF 4. Battery Test 5. Reset Button 6. Audio Mute 7. Sensitivity Up 8. Sensitivity Down 9. LED Leak Indicators 10. Flexible Probe 3

Summary of the content on the page No. 6

GETTING STARTED Installing Batteries 1. Remove the battery compartment door located on the bottom of the instrument, as shown below. Install batteries, Positive Polarity inwarels (towards the unit). (See figure 2). Fig. 2 OPERATING FEATURES Power Indication/Battery Test The ACL2500 provides two indications of battery voltage status; a Constant Power indicator (leftmost LED) and a Battery Test function. The Constant Power indicator allows the user to see the battery level at all times. The LE

Summary of the content on the page No. 7

OPERATING FEATURES • Battery Test Function. This feature is activated by pressing the Battery Test key. When pressed, the LED’s will display a three color bargraph indication of true battery voltage (See Fig. 4). The LED’s correspond to voltage as shown in the figure. Not all LEDs will always be on; the number of LEDs on, indicate the voltage level. 2.5V 2.6V 2.65V 2.7V 2.8V 2.9V 3.0V Red Orange Green Fig. 4 BATTERY TEST DISPLAY The battery voltage display will remain as long as the BATTERY TES

Summary of the content on the page No. 8

OPERATING FEATURES When the unit is switched on, it is set to sensitivity level 5. 1. To adjust the sensitivity, press the SENSITIVITYa or SENSITIVITYb key. When the key is pressed, the visual display will show the LED’s red. The number of LED’s lit, indicates the level (See Fig 5). Level one (lowest sensitivity) is shown by the leftmost LED. Counting from left, levels 2 through 7 are indicated by the corresponding number of red LED’s; i.e. level 7 is shown by all LED’s lit. 2. Pressing the SENS

Summary of the content on the page No. 9

OPERATING INSTRUCTIONS OPERATION: 1. Switch the unit on by pressing the ON/OFF key. The display will illuminate with the reset indication (Left LED green, all others Orange) for 2 seconds. 2. Verify the battery level by observing the constant power indicator (see above). 3. Upon turn on, the unit is set to sensitivity level 5. A rapid, but steady beep rate will be heard. If desired, the sensitivity can be adjusted by pressing the SENSI- TIVITYa or SENSITIVITYb key, as described above. 4. Begin

Summary of the content on the page No. 10

OPERATING TIPS 2. Take care not to contaminate the detector probe tip if the part being tested is contaminated. If the part is particularly dirty, or condensate (moisture) is present, it should be wiped off with a dry shop towel or blown off with shop air. No clean- ers or solvents should be used, since the detector may be sensitive to their ingredients. 3. Visually trace the entire refrigerant system, and look for signs of air conditioning lubricant leakage, damage, and corrosion on all lines,

Summary of the content on the page No. 11

OPERATING TIPS All Systems - 8. Following any service to the refrigerant system and any other service which dis- turbs the refrigerant system, a leak test of the repair and of the service ports of the refrigerant system should be done. APPLICATIONS The ACL2500 Leak Detector may also be used to: • Detect leaks in other systems and storage/recovery containers. It will respond to ALL halogenated (contains Chlorine or Fluorine) refrigerants. This includes, but is not limited to: CFCs e.g. R12,R11,R5

Summary of the content on the page No. 12

MAINTENANCE 3. If the tip itself is dirty it can be cleaned by immersing in a mild solvent, such as alcohol, for a few seconds, and then using compressed air and/or a shop towel to clean. NOTE: Never use solvents such as gasoline, turpentine, mineral spirits, etc... as these will leave a detectable residue and desensitize your unit. Sensing tip replacement: The tip will eventually wear out and require replace- ment. It is difficult to predict exactly when this will occur since tip longevity is

Summary of the content on the page No. 13

SPECIFICATIONS Power Supply: 3V DC; two “C” cell Alkaline batteries Maximum Sensitivity: Per SAE J1627 Rating Criteria; Certified for R12, R22 and R134a @ 0.5 oz/yr. (14gr/yr) Ultimate sensitivity: less than 0.1 oz/yr (3 gr/yr) for all Halogen based refrigerants. Sensing Tip Life: Approx. 20 hours Operating Temperature: 30° to 125° F (0°to 52° C) Battery Life: Approximately 30 hours normal use Duty Cycle: Continuous, no limitation Response Time: Instantaneous Reset Time: One second Wa

Summary of the content on the page No. 14

Designed & Engineered in the USA Manufactured in China Toll Free Customer Service: 1-800-327-5060 100839ACL RevA


Alternative user manuals
# User manual Category Download
1 2JANE Surround Sound System HTS-GS1 User manual Refrigerator 4
2 3Com Phaser 7750 User manual Refrigerator 1
3 3Com iQ 10 User manual Refrigerator 0
4 3Com PowerDual iQ 10 iQ 10C User manual Refrigerator 1
5 3Com PowerDual iQ 10 iQ 10P User manual Refrigerator 2
6 3Com Dell D-Family Battery Charger CHRG01L User manual Refrigerator 0
7 3Com PowerDual iQ 10 iQ 10PC User manual Refrigerator 0
8 3Com Preface Firmware Version 1.07 VFD-D D User manual Refrigerator 0
9 3D Connexion Infinity Systems Interlude IL120s User manual Refrigerator 1
10 3D Connexion Cisco Catalyst Blade Switch 3040 for FSC Hardware OL-10694-01 User manual Refrigerator 0
11 3D Connexion 42" SNOW THROWER LST42B User manual Refrigerator 0
12 3D Connexion Cisco SCA BB SNMP Real Time Monitoring OL-12491-01 User manual Refrigerator 0
13 3D Connexion Primergy ServerView Suite TivoII User manual Refrigerator 0
14 3D Innovations The Xerox DocuPrint Color Laser Printer NC60 User manual Refrigerator 0
15 3G Green Green Globe Automatic Transfer Switch ZTS Series User manual Refrigerator 0