Impulse DO3623R user manual

User manual for the device Impulse DO3623R

Device: Impulse DO3623R
Category: Refrigerator
Manufacturer: Impulse
Size: 1.78 MB
Added : 8/20/2014
Number of pages: 27
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Impulse DO3623R. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Impulse DO3623R.

For your convenience

If looking through the Impulse DO3623R user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Impulse DO3623R on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Impulse DO3623R to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Impulse DO3623R User manual - Online PDF
Advertisement
« Page 1 of 27 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Impulse DO3623R but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Impulse DO3623R. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

READ AND SAVE THESE INSTRUCTIONS
INSTALLATION &
OPERATING MANUAL
PN 99574

OPE SERVI N REF CE DR RIGE OP-I RATE N RED FRIGE SELF-SE RATRVICE ED MERC MEH RANDIS CHANDISE ER R
Model DO3637R
Model DO4837R
Model DO3637R 38 1/8”L x 28 5/8”D x 37 1/4”H (Upper Display Case Only)
38 1/8”L x 28 5/8”D x 61 1/8”H (Upper Display Case + Drop-In Refrigeration Unit)

Model DO4837R 50 1/8”L x 28 5/8”D x 37 1/4”H (Upper Display Case Only)
50 1/8”L x 28 5/8”D x 61 1/8”H (Upper Display Cas

Summary of the content on the page No. 2

TABLE OF CONTENTS 3 OVERVIEW AND WARNINGS ...………………………..…………………..…….………….....….. 4 CUSTOMER CABINET PROVISIONS…………………..…………………..…….………….....….. CLEARANCE AND AIR FLOW ...………………………..…………………..…….………….....….. 5 6 VENTING INSTRUCTIONS FOR AIR INTAKE / EXHAUST - DO3637R …………………….. 7 VENTING INSTRUCTIONS FOR AIR INTAKE / EXHAUST - DO4837R …………………….. VENTING INSTRUCTIONS FOR AIR INTAKE / EXHAUST - DO3623R …………………….. 8 9 INSTALLATION ………………………………………………………………………………

Summary of the content on the page No. 3

OVERVIEW AND WARNINGS OVERVIEW • The Structural Concepts® Oasis® refrigerated self-service cases are designed to merchandise packaged products at 5° Celsius / 41° Fahrenheit or less product temperatures. • These cases should be installed and operated according to the following instructions to insure proper performance. • This unit is designed for the display of products in ambient store conditions where temperatures and humidity are maintained at a maximum of 24°C / 75°F and 55% r

Summary of the content on the page No. 4

CUSTOMER CABINET PROVISIONS Customer Cabinet Provisions • Customer provided cabinet must adhere to the minimum requirements in ANSI/UL Std. 471 and ANSI/NSF Std. 7. • Among the factors that are to be taken into consideration when judging the acceptability of a cabinet or similar enclosure are mechanical strength, resistance to impact, moisture-absorptive properties, flame resistance, resistance to distortion at temperatures to which the material may be subjected under conditions of u

Summary of the content on the page No. 5

CLEARANCE AND AIR FLOW Service Top Cutout Dimensions Note: See Manual Cover for DO3637R, DO4837R, DO3623R & 4823R Service Top Cutout Dimensions. Clearance Dimensions The Refrigerated section must maintain airflow clear- ance. Dimensions are as follow. 1. 4" Minimum Spacing from bottom of refrigeration frame to bottom of cabinet or floor required for ade- quate air flow. 2. 9 1/2" Countertop / Facia enclosure space on cabi- nets or counter to allow for pullout system slide-out. 3

Summary of the content on the page No. 6

FACIA ENCLOSURE 32” MINIMUM MAINTENANCE ACCESS SPACE 13” MINIMUM AIR INTAKE SPACE 9 1/2” 19” MINIMUM AIR EXHAUST SPACE 9 1/2” 13” MINIMUM AIR INTAKE SPACE 15” MINIMUM MAINTENANCE ACCESS P S ACE 10 1/2” MIN. AIR EXHAUST SPACE VENTING INSTRUCTIONS FOR AIR INTAKE / EXHAUST - DO3637R BACK VIEW OF CABINET AFTER POSITIONED ON CUSTOMER-SUPPLIED COUNTER/BASE Warning: The minimum intake and exhaust areas must be allowed (as illustrated below) or case temperatures may fluct

Summary of the content on the page No. 7

1/2 9 ” 19” MINIMUM X T AIR E HAUS SPACE 25” MINIMUM AIR INTAKE SPACE 45” MINIMUM MAINTENANCE ACCESS SPACE 9 1/2” 2” FACIA ENCLOSURE 1 3” MINIMUM AIR INTAKE SPACE 15” MINIMUM MAINTENANCE ACCESS SPACE 15” MINIMUM AIR EXHAUST SPACE VENTING INSTRUCTIONS FOR AIR INTAKE / EXHAUST - DO4837R BACK VIEW OF CABINET AFTER POSITIONED ON CUSTOMER-SUPPLIED COUNTER/BASE Warning: The minimum intake and exhaust areas must be allowed (as illustrated below) or case temperatures

Summary of the content on the page No. 8

VENTING INSTRUCTIONS FOR AIR INTAKE / EXHAUST - DO3623R & DO4823R BACK VIEW OF CABINET AFTER POSITIONED ON CUSTOMER-SUPPLIED COUNTER/BASE Warning: The minimum intake and exhaust areas must be allowed (as illustrated below) or case temperatures may fluctuate beyond safe parameters. NOTES: 1. BACK OF CABINET MUST BE VENTED A MINIMUM OF 10 1/2” x 11” FOR AIR INTAKE. 2. BACK OF CABINET MUST BE VENTED A MINIMUM OF 3/4” x 15” FOR AIR EXHAUST. 3. BACK OF CABINET MUST PROVIDE A MINIMUM OF

Summary of the content on the page No. 9

INSTALLATION 1. Remove Case From Skid 2. Display Case Setup Caution: Case must always remain supported • SCC® Service Drop-In Refrigerated Merchan- or center of gravity may allow case to fall. Slide diser Case consists of two sections: The Upper to rear of skid and tip backward off skid while Display Case and Drop-In Refrigerated Section. maintaining support. See illustration below. • As both sections make up one conjoined unit, it is both large and heavy. A team effort is re- quired fo

Summary of the content on the page No. 10

START-UP AND OPERATION Case Start-Up Upper • Plug cord into a certified electrical outlet with Light Display Switch ground. Case • Turn on the Main Power Switch. Switch is in Spirit-Filled Thermometer the Drop-In Refrigerated Section on the rear Shelves (see illustra- right hand side of base. tion below) • The Temperature Control Module (LED) will illuminate. Evaporator coil fans and the Deck compressor motor should turn on. • From the front of the case, raise the deck

Summary of the content on the page No. 11

MAINTENANCE FUNDAMENTALS Adjustable Shelf • Adjustment of the angle of the shelves can be Shelf Assembly made by pivoting the lower portion of the shelf bracket in the upright. • The shelves can be adjusted to an angle of: 0, 5, and 10 degrees. • See illustration at right. Shelf Bracket Shelf Assembly Removal • Shelves can be removed for cleaning or ad- Adjustment justments Notches • For lighted shelving, turn off power, unplug the light cord. • Lift shelf straight up to

Summary of the content on the page No. 12

MAINTENANCE FUNDAMENTALS, CONTINUED Warning, disconnect power before provid- ing maintenance and service to unit. As- sembly or disassembly and servicing to be accomplished by licensed electrical con- tractor. Fan Evaporator Coil Fans Access and Removal Shroud • Fans may be accessed by removing Deck Coil (covering Fan Shroud, Fan Housing and Coil). See illustrations at right. Fan Light Ballast Access Housing Light ballast is located inside the Electrical J- Box. Electric

Summary of the content on the page No. 13

MAINTENANCE FUNDAMENTALS, CONTINUED Removing the Rear Doors Shelving • Remove Thumbscrews (4 each side). Lamp Thumbscrew removal will allow Rear Thumbscrew Doors to be removed. • See illustration on this page for locations of Thumbscrews, Nuts, Perforated Acrylic Plenum, etc. • Move the doors toward the center of the case. • Starting with the Outer Door (right hand door from rear of the case), individually lift each door up toward top of the case and pivot the bottom of door

Summary of the content on the page No. 14

REFRIGERATION FUNDAMENTALS Refrigeration Access, Connections & Servicing Assembly or disassembly and servicing to be accomplished by licensed refrigeration contractor. • Refrigeration Unit slides directly out from lower section to allow for servicing. • Service connections are located in the Refrigeration Slide-Out (shown at right). • Refrigeration Unit is equipped with evaporator pan for case condensation. Temperature Insure evaporator pan is plugged in 110V Control recept

Summary of the content on the page No. 15

REFRIGERATION SLIDE-OUT EXPLODED PICTORIAL The following images show the various parts pertaining to the Refrigeration Unit (that is slid directly out from lower section) to be serviced. Condensing Coil Electrical (and internal fan) Junction Box Refrigeration Service Valve Capacitor Sight Glass Condensate Pan Receiver Copper Tubing Flexible Hose Condensing Connections Unit Copper Dryer Filter Tubing R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.

Summary of the content on the page No. 16

TECHNICAL INFORMATION SHEET - MODEL DO3637R R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com 16

Summary of the content on the page No. 17

TECHNICAL INFORMATION SHEET - MODEL DO4837R R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com 17

Summary of the content on the page No. 18

TECHNICAL INFORMATION SHEET - MODEL DO3623R R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com 18

Summary of the content on the page No. 19

TECHNICAL INFORMATION SHEET - MODEL DO4823R R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com 19

Summary of the content on the page No. 20

TROUBLESHOOTING Product is Drying Out Check the relative humidity in the store. Water on the Floor Check that all of the hoses are connected. Check that the drain trap is free of debris. Excessive Fan Noise Check that the case is aligned properly. Check that nothing is obstructing the blade rotation. Check that the fan shroud is properly secured. System is not Operating Confirm the utility power is on. Check that the MAIN power switch is on. Check that the unit is proper


Alternative user manuals
# User manual Category Download
1 Impulse DO3637R User manual Refrigerator 2
2 Impulse DO4823R User manual Refrigerator 1
3 Impulse DO4837R User manual Refrigerator 0
4 2JANE Surround Sound System HTS-GS1 User manual Refrigerator 4
5 3Com Phaser 7750 User manual Refrigerator 1
6 3Com iQ 10 User manual Refrigerator 0
7 3Com PowerDual iQ 10 iQ 10C User manual Refrigerator 1
8 3Com PowerDual iQ 10 iQ 10P User manual Refrigerator 2
9 3Com Dell D-Family Battery Charger CHRG01L User manual Refrigerator 0
10 3Com PowerDual iQ 10 iQ 10PC User manual Refrigerator 0
11 3Com Preface Firmware Version 1.07 VFD-D D User manual Refrigerator 0
12 3D Connexion Infinity Systems Interlude IL120s User manual Refrigerator 1
13 3D Connexion Cisco Catalyst Blade Switch 3040 for FSC Hardware OL-10694-01 User manual Refrigerator 0
14 3D Connexion 42" SNOW THROWER LST42B User manual Refrigerator 0