Henny Penny COLD TOPS CMC/CMR-103 user manual

User manual for the device Henny Penny COLD TOPS CMC/CMR-103

Device: Henny Penny COLD TOPS CMC/CMR-103
Category: Refrigerator
Manufacturer: Henny Penny
Size: 0.87 MB
Added : 10/30/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Henny Penny COLD TOPS CMC/CMR-103. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Henny Penny COLD TOPS CMC/CMR-103.

For your convenience

If looking through the Henny Penny COLD TOPS CMC/CMR-103 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Henny Penny COLD TOPS CMC/CMR-103 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Henny Penny COLD TOPS CMC/CMR-103 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Henny Penny COLD TOPS CMC/CMR-103 User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Henny Penny COLD TOPS CMC/CMR-103 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Henny Penny COLD TOPS CMC/CMR-103. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Henny Penny
Cold Tops
Model CMC/CMR-103
Model CMC/CMR-104
Model CMC/CMR-105
Model CMC/CMR-106
Model CMC/CMR-107
OPERATOR’S MANUAL

Summary of the content on the page No. 2

Model CMC/CMR-103,104,105,106,107 LIMITED WARRANTY FOR HENNY PENNY APPLIANCES Subject to the following conditions, Henny Penny Corporation makes the following limited warranties to the original purchaser only for Henny Penny appliances and replacement parts: NEW EQUIPMENT: Any part of a new appliance, except lamps and fuses, which proves to be defective in material or workmanship within two (2) years from date of original installation, will be repaired or replaced without charge F.O.B. factory

Summary of the content on the page No. 3

Model CMC/CMR-103,104,105,106,107 TABLE OF CONTENTS Section Page Section 1. INTRODUCTION ................................................................................................................... 1-1 1-1. Henny Penny Cold Tops .............................................................................................. 1-1 1-2. Features ....................................................................................................................... 1-1 1-3. Proper Care ........

Summary of the content on the page No. 4

Model CMC/CMR-103,104,105,106,107 SECTION 1. INTRODUCTION 1-1. COLD TOPS The Henny Penny cold tops are full service units, designed to hold chilled or refrigerated products. The units are electronically controlled for easy use and for consistent operation. 1-2. FEATURES • Can be matched with hot or cold merchandisers in all lengths • Electronic Controls • Stackable units on top of bases • Low speed air circulation • Easily maintained • Fluorescent lighting with electronic ballast (CE-m

Summary of the content on the page No. 5

Model CMC/CMR-103,104,105,106,107 1-5. SAFETY The Henny Penny cold tops have many safety features incorporated. However, the only way to ensure a safe operation is to fully understand the proper installation, operation, and maintenance procedures. The instructions in this manual have been prepared to aid you in learning the proper procedures. Where information is of particular importance or safety related, the words NOTICE, CAUTION, and WARNING, are used. Their usage is described below. SA

Summary of the content on the page No. 6

Model CMC/CMR-103,104,105,106,107 SECTION 2. INSTALLATION 2-1. INTRODUCTION This section provides the installation for Henny Penny cold tops. Installation of this unit should be performed only by a qualified service technician. Do not puncture the unit with any objects such as drills or screws, or component damage or electrical shock could result. 2-2. UNPACKING The Henny Penny Cold Top has been tested, inspected, and expertly packed to insure arrival at its destination in the best poss

Summary of the content on the page No. 7

Model CMC/CMR-103,104,105,106,107 2-2. UNPACKING (Continued) Take care when moving the fryer to prevent personal injury or damage to the refrigeration system. The CMC-107s weigh over 700 lbs. (318 kg). 4. Peel off any protective covering from exterior of the cabinet. 5. Install the grids into unit. 6. Unpack sliding thermal doors and side glass. Install on rear and side of unit. 7. Your cold top is now ready for operation. 2-3. ELECTRICAL The Cold Top is available as a 120

Summary of the content on the page No. 8

Model CMC/CMR-103,104,105,106,107 2-4. LOCATION Place the cold tops in an area where product can be loaded and unloaded without interruption. For proper operation, level the unit by adjusting the bolts under the base, and leave 3 feet (91.44 cm) clearance behind the unit for ventilation and service. For maximum efficiency, units should be operated in an air-condi- tioned environment, with maximum air temperature of 75° F (24° C), and 55% relative humidity. Wait at least 4 hours before plu

Summary of the content on the page No. 9

Model CMC/CMR-103,104,105,106,107 2-7. COMPRESSOR SIZE Model CMC Motor HP CMR Motor HP AND LOAD CMC/ BTU Load UL CE UL CE CMR R-22 R-134a R-22 R-134a 103 2860 1/4 1/3 Remote 104 2860 1/4 1/3 Compressor 105 2830 1/3 1/2 Supplied 106 2830 1/3 1/2 By Other 107 3840 1/2 1/2 BTU load sized at evaporator temperature + 20 F or -6 C. 2-8. FOOT PRINT DRAWING CMR MODELS DRAIN& REFRIGERATION CONNECTIONS 2-4 303

Summary of the content on the page No. 10

Model CMC/CMR-103,104,105,106,107 2-9. CUT OUT DIMENSIONS FOR DRY BASE OR TABLE INSTALLATION 303 2-5

Summary of the content on the page No. 11

Model CMC/CMR-103,104,105,106,107 2-10. FLOURESCENT LIGHTING No. AND BULB REPLACEMENT Model of Lights Size CMR/CMC-103 1 36 in. (.914 m) CMR/CMC-104 1 48 in. (1.22 m) CMR/CMC-105 1 24 in. (.610 m) 1 36 in. (.914 m) CMR/CMC-106 2 36 in. (.914 m) CMR/CMC-107 1 36 in. (.914 m) 1 48 in. (1.22 m) UL Units 1. Pull the bulb out of the sockets. 2. Remove the bulb guard caps. 3. Install new fluorescent bulb in reverse order. CE Units 1. Remove the bulb cover. 2. Rotate the bulb. 3. Pull

Summary of the content on the page No. 12

Model CMC/CMR-103,104,105,106,107 1. Remove bolts securing the Cold Top to the skid, and save bolts 2-11. COLD TOP ON A COLD for later use. BASE INSTALLATION INSTRUCTIONS 2. Carefully set Cold Top on top of the Cold Base. Take care when moving the fryer to prevent personal injury or damage to the refrigeration system. The CMC-107s weigh over 700 lbs. (318 kg). 3. Line up the 2 front holes and secure the top to the base using the bolts from step 1. Figure 2-1. Figure

Summary of the content on the page No. 13

Model CMC/CMR-103,104,105,106,107 SECTION 3. OPERATION 3-1. INTRODUCTION This section provides explanations of all controls, along with operating procedures and daily maintenance. Read the Introduction, Installation and Opeation Sections before operating the unit. Wait at least 4 hours before plugging the unit into an electrical supply. The gases and oils in the refrigeration system needs to settle before operating the compressor, or damage to the compressor could result. 3-2. OPE

Summary of the content on the page No. 14

Model CMC/CMR-103,104,105,106,107 3-2. OPERATING CONTROLS (Continued) 3 2 1 Figure 3-1 4 5 303 3-2

Summary of the content on the page No. 15

Model CMC/CMR-103,104,105,106,107 3-3. BASIC OPERATION 1. Turn power switch to ON position. 2. Wait for temperature to reach operating temperature, 34 to 38° F (1.1 to 3.3° C). 3. Place chilled product into case. Do not block the air return and air discharge vents with product. Product temperatures may become unsafe, and increase operating costs. Do not use mechanical devices or other means to quicken the defrosting process, other than those recommended by the manufacturer, or damage to

Summary of the content on the page No. 16

Model CMC/CMR-103,104,105,106,107 3-4. CLEANING Every 3 Months: (Continued) 1. Remove all electrical power supplied to the unit by unplugging the power cord from the wall, or by turning off the wall circuit breaker. 2. Remove all product from the unit. 3. Remove the riser and trays from the unit and clean with soap and water at a sink. 4. Clean interior surfaces with a soft cloth, soap and water. Do not use steel wool, other abrasive cleaners or cleaners/sanitizers containing

Summary of the content on the page No. 17

Model CMC/CMR-103,104,105,106,107 3-5. PROGRAMMING 1. Press and hold for 4 seconds. The “DEF/SET” light flashes in display. Temperature Setpoint 2. Press the or to change the temperature setpoint, within 5 seconds. After 5 seconds, the last entered setpoint stays in memory. Other Parameters 3. Press to access the other parameters. Each press of the accesses the next parameter. The parameters are: d: differential (-15...15 range) LS: lower set; lower user-access set

Summary of the content on the page No. 18

Model CMC/CMR-103,104,105,106,107 3-5. PROGRAMMING dS: defrost system (computation); dF=digifrost Feature; Continued defrost start time based on total compressor running time rt=real time; defrost start frequency, based on real time dI: defrost interval; defrost frequency in hours, based on the selection of “dS” dE: defrost endurance; total (maximum) length of a defrost cycle, expressed in minutes. (1...99 range) dL: display lock; temperature display is locked during a d

Summary of the content on the page No. 19

Model CMC/CMR-103,104,105,106,107 3-6. FLUORESCENT BULB UL Units REPLACEMENT 1. Pull the bulb out of the sockets. 2. Remove the bulb guard caps. 3. Install new fluorescent bulb in reverse order. CE Units 1. Remove the bulb cover. 2. Rotate the bulb. 3. Pull the lamp out of the sockets. 4. Install new fluorescent lamp in reverse order. 3-7 1102

Summary of the content on the page No. 20

Model CMC/CMR-103,104,105,106,107 DIAGRAM FOR CMC MODEL 1002 3-8


Alternative user manuals
# User manual Category Download
1 Henny Penny CBC/CBR-105 User manual Refrigerator 1
2 Henny Penny CBC/CBR-103 User manual Refrigerator 1
3 Henny Penny CBC/CBR-106 User manual Refrigerator 1
4 Henny Penny COLD TOPS CMC/CMR-104 User manual Refrigerator 2
5 Henny Penny COLD TOPS CMC/CMR-105 User manual Refrigerator 1
6 Henny Penny CBC/CBR-107 User manual Refrigerator 0
7 Henny Penny COLD TOPS CMC/CMR-106 User manual Refrigerator 1
8 Henny Penny COLD TOPS CMC/CMR-107 User manual Refrigerator 2
9 Henny Penny CBC/CBR-104 User manual Refrigerator 1
10 Henny Penny HDS-200 User manual Refrigerator 1
11 Henny Penny COLD TOPS CMC/CMR-103 User manual Freezer 1
12 2JANE Surround Sound System HTS-GS1 User manual Refrigerator 4
13 3Com Phaser 7750 User manual Refrigerator 1
14 3Com iQ 10 User manual Refrigerator 0
15 3Com PowerDual iQ 10 iQ 10C User manual Refrigerator 1
16 3Com PowerDual iQ 10 iQ 10P User manual Refrigerator 2