Emerson Liebert Deluxe System/3 VE user manual

User manual for the device Emerson Liebert Deluxe System/3 VE

Device: Emerson Liebert Deluxe System/3 VE
Category: Refrigerator
Manufacturer: Emerson
Size: 3.42 MB
Added : 7/4/2014
Number of pages: 80
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson Liebert Deluxe System/3 VE. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson Liebert Deluxe System/3 VE.

For your convenience

If looking through the Emerson Liebert Deluxe System/3 VE user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson Liebert Deluxe System/3 VE on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson Liebert Deluxe System/3 VE to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson Liebert Deluxe System/3 VE User manual - Online PDF
Advertisement
« Page 1 of 80 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson Liebert Deluxe System/3 VE but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson Liebert Deluxe System/3 VE. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Precision Cooling
For Business-Critical Continuity™

Liebert Deluxe System/3
Operation and Maintenance Manual
50 and 60 Hz, 6-30 Ton DX Systems (DH/DE/VH/VE); 12-60 Ton CW Systems (FH/UH)

Summary of the content on the page No. 2

Summary of the content on the page No. 3

TABLE OF CONTENTS 1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1.1 System Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1.1 Compressorized Two-Step Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1.2 Compressorized Four-Step Systems . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 4

4.4 Main Menu (AG)—View/Set Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 4.4.1 Active Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 4.4.2 Alarm History Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 4.4.3 Setup Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 5

5.0 RESPONSE BY CONTROL TYPE—ADVANCED MICROPROCESSOR CONTROLS . . . . . . . . . . .33 5.1 Temperature Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.1.1 Cooling/Heating Required, in Percent (%) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.1.2 Response to Control Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.1.

Summary of the content on the page No. 6

7.0 COMPONENT OPERATION AND MAINTENANCE, CHECKS AND ADJUSTMENTS. . . . . . . . . . . .48 7.1 System Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 7.1.1 Environmental Control Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 7.1.2 Electric Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 7

FIGURES Figure 1 Advanced microprocessor control panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Figure 2 Advanced microprocessor (AM) control menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Figure 3 Advanced microprocessor with graphics control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Figure 4 Advanced microprocessor with graphics (AG) control menu . . . . . . . .

Summary of the content on the page No. 8

vi

Summary of the content on the page No. 9

Introduction 1.0 INTRODUCTION 1.1 System Description Liebert Deluxe environmental control systems are available in several configurations. Each configu- ration can operate with either Advanced Microprocessor Controls (AM), or Advanced Microprocessor Controls with Graphics (AG). A brief description of each, including operational differences, are listed below. Check model numbers to see what is supplied with your unit. 1.1.1 Compressorized Two-Step Systems These systems may be air, water, or gly

Summary of the content on the page No. 10

Introduction 1.1.3 Chilled Water Systems These systems utilize a central chiller and control cooling by modulating a control valve in the chilled water line. Cooling Modulating output water valve Heating Three stages of electric reheat standard; steam/hot water optional Humidification Infrared standard, steam grid and steam generating optional Dehumidification Chilled water valve opens proportionally in response to room needs ™ 1.1.4 GLYCOOL (Chilled Glycol Cooling) Systems ™ GLYCOOL systems h

Summary of the content on the page No. 11

Initial Start-Up Procedure 2.0 INITIAL START-UP PROCEDURE Before beginning start-up, make certain that unit was installed according to the instructions in the Installation Manual. All exterior panels must be in place. Locate the Start-Up form supplied with your unit documents. Complete the form during your start-up and mail it to Liebert when start-up is completed. Contact your Liebert supplier if you have any ques- tions or problems during your unit installation, start-up, or operation. WARNI

Summary of the content on the page No. 12

Advanced Microprocessor Controls Setup 3.0 ADVANCED MICROPROCESSOR CONTROLS SETUP The Advanced Microprocessor (AM) Control for your Liebert Deluxe unit features an easy to use menu driven LCD display. The menus, control features, and circuit board details are described in this section. For more control details refer to 5.0 - Response by Control Type—Advanced Micropro- cessor Controls, and for more alarm information refer to 6.0 - Alarm Descriptions and Solu- tions. 3.1 Basics Control keys incl

Summary of the content on the page No. 13

Advanced Microprocessor Controls Setup Figure 2 Advanced microprocessor (AM) control menu Main Menu Normal 72° 50% Reheat Status/Alarm Data Display Cooling Setpoints/Setup Dehumidifying Date and Time No Alarms Present Status Display Status Alarm Data Setpoints/Setup Date and Time Status Display Active Alarms View Setpoints 15-APR-2001 09:30:00 75°F 59% RH Operating Status Setup System Cooling Alarm History Log Run Diagnostics ENTER to change Dehumidifying Run Hours Log Change Passwords ESCap

Summary of the content on the page No. 14

Advanced Microprocessor Controls Setup 3.3 Main Menu (AM)—Status/Alarm Data Selecting STATUS/ALARM DATA from the Main Menu will display the following selections: ACTIVE ALARMS OPERATING STATUS ALARM HISTORY LOG RUN HOURS LOG ANALOG SENSORS 3.3.1 Active Alarms This screen, a submenu of Status/Alarm Data, displays any active alarm. The alarms are numbered, #1 being the most recent. If there are no active alarms, then “NO ALARMS PRESENT” will be dis- played. 3.3.2 Operating Status The Operating St

Summary of the content on the page No. 15

Advanced Microprocessor Controls Setup 3.3.5 Analog Sensors The four (4) analog sensor inputs can be monitored from this submenu of Status/Alarm Data. The inputs are filtered and displayed along with the text label assigned during setup. See Analog Setup on page 12. 3.4 Main Menu (AM)—Setpoints/Setup Selecting Setpoints/Setup from the Main Menu will display the following selections: VIEW SETPOINTS SETUP SYSTEM RUN DIAGNOSTICS CHANGE PASSWORDS NOTE Setpoints and system setup parameters are kept

Summary of the content on the page No. 16

Advanced Microprocessor Controls Setup Setup Operation The Setup Operation permits the review and/or adjustment of the unit configuration. The menu may include: Cold Start: This feature, also referred to as Positive Start or Winter Start Kit, allows for the low- pressure switch to be ignored for the programmed time during a cold start of the compressors, enabling the unit to run at low suction pressures. Entering a “0” for this time will bypass this feature. A “1”, will bypass the low-pressur

Summary of the content on the page No. 17

Advanced Microprocessor Controls Setup Select Options The following table lists choices on the Select Options menu. These should match the options installed with your unit and should not need to change during normal operation. Table 3 Select options Option Selection Heating Yes or No Humidifier Yes or No Dehumidifier Yes or No Humidifier Pan Small or Large Hot Gas Reheat Yes or No Heat Stages* 2 or 3 Dehumidification Stages 1 or 2 *If heat stage is set to 2 on a chilled water unit, the reheat

Summary of the content on the page No. 18

Advanced Microprocessor Controls Setup Dehumidification with Normal or Delayed Reheat: Dehumidification with normal reheat allows for operating BOTH compressors and reheats simultaneously. It is very important that electrical ser- vice to the unit be sized and wired for this option if selected. CAUTION ! If the electrical service to the unit is not properly sized for this option, it could trip the building circuit breakers (or fuses) or, in extreme cases, damage the building wiring. With delay

Summary of the content on the page No. 19

Advanced Microprocessor Controls Setup Table 5 Alarm default time delay Alarm Default Delay (seconds) Humidifier Problem 2 High Head Pressure 1 2 High Head Pressure 2 2 Change Filter 2 Loss of Air Flow 3 Custom Alarm #1 0 Custom Alarm #2 0 Custom Alarm #3 0 Custom Alarm #4 6 High Temperature 30 Low Temperature 30 High Humidity 30 Low Humidity 30 Low Suction Pressure 1, 2 0 Short Cycle 1, 2 0 Compressor #1 Overload 2 Compressor #2 Overload 2 Main Fan Overload 5 Loss of Power 0 Enable Alarms: Each

Summary of the content on the page No. 20

Advanced Microprocessor Controls Setup Standard Alarm Messages • Water under floor • Smoke detected • Standby GC pump on • Loss of water flow • Standby unit on For more information concerning alarms, see 6.0 - Alarm Descriptions and Solutions. Humidity Control Method The user may select between relative (direct) and absolute (predictive) humidity control. If relative is selected, the RH control is taken directly from the RH sensor. If absolute is selected, the RH control is automatically adjus


Alternative user manuals
# User manual Category Download
1 Emerson CL-RSC User manual Refrigerator 10
2 Emerson CR175W User manual Refrigerator 7
3 Emerson CR500 User manual Refrigerator 89
4 Emerson ENV10G User manual Refrigerator 0
5 Emerson 1.5 TO 10 TONS, 60HZ User manual Refrigerator 0
6 Emerson DE User manual Refrigerator 3
7 Emerson CSU 3000 User manual Refrigerator 0
8 Emerson CL-RSC User manual Refrigerator 0
9 Emerson ENV20G User manual Refrigerator 1
10 Emerson FR11SL User manual Refrigerator 1
11 Emerson E2 User manual Refrigerator 3
12 Emerson ER40 User manual Refrigerator 1
13 Emerson Fluid Chiller User manual Refrigerator 9
14 Emerson Liebert Deluxe System/3 DH User manual Refrigerator 77
15 Emerson Liebert XDCF User manual Refrigerator 1
16 2JANE Surround Sound System HTS-GS1 User manual Refrigerator 4
17 3Com Phaser 7750 User manual Refrigerator 1
18 3Com iQ 10 User manual Refrigerator 0
19 3Com PowerDual iQ 10 iQ 10C User manual Refrigerator 1
20 3Com PowerDual iQ 10 iQ 10P User manual Refrigerator 2