Delfield Shelleybasic user manual

User manual for the device Delfield Shelleybasic

Device: Delfield Shelleybasic
Category: Refrigerator
Manufacturer: Delfield
Size: 1.1 MB
Added : 8/20/2014
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Delfield Shelleybasic. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Delfield Shelleybasic.

For your convenience

If looking through the Delfield Shelleybasic user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Delfield Shelleybasic on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Delfield Shelleybasic to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Delfield Shelleybasic User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Delfield Shelleybasic but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Delfield Shelleybasic. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


®
Delfield
SHELLEYBASIC BY DELFIELD
Service, Installation and Care Manual
Please read this manual completely before attempting to install or operate this equipment!
Notify carrier of damage! Inspect all components immediately. See page 2.
Effective Date June 2008
IMPORTANT INFORMATION
CAUTION READ BEFORE USE
PLEASE SAVE THESE INSTRUCTIONS!

Summary of the content on the page No. 2

Shelleybasic by Delfield Service & Installation Manual Contents Serial Number Information The serial number on self-contained refrigerated units is on the electrical specifications tag located near the condensing unit. Serial Number Information ..................................................... 2 Receiving And Inspecting The Equipment ............................. 2 On hot food pans and hot/cold combination pans, the serial Specifications ...................................................

Summary of the content on the page No. 3

Shelleybasic by Delfield Service & Installation Manual Specifications Shelleybasic by Delfield Heated Counters Food Model L D H Ship Wt Wells Volts Plug Amp SE-H2 39” 29” 36” 215lbs (98kg) 2 120/208-230 14-20P 10.0/11.0 SE-H3 50” 29” 36” 265lbs (120kg) 3 120/208-230 14-20P 15.0/16.0 SE-H4 64” 29” 36” 320lbs (145kg) 4 120/208-230 14-30P 20.0/22.0 SE-H5 78” 29” 36” 410lbs (186kg) 5 120/208-230 14-50P 24.0/27.0 SE-H6 92” 29” 36” 500lbs (227kg) 6 120/208-230 14-50P 29.0/32.0 Shelleybasic by Delfiel

Summary of the content on the page No. 4

Shelleybasic by Delfield Service & Installation Manual Specifications continued Shelleybasic by Delfield Utility Counters Model L D H Ship Wt SE-U2 39” 29” 36” 150lbs (68kg) SE-U3 50” 29” 36” 170lbs (77kg) SE-U4 64” 29” 36” 200lbs (91kg) SE-U5 78” 29” 36” 230lbs (104kg) SE-U6 92” 29” 36” 280lbs (127kg) Shelleybasic by Delfield Cashier’s Stand Model L D H Ship Wt SE-CS 29” 29” 36” 170lbs (77kg) Shelleybasic by Delfield Tray Stand Model L D H Ship Wt SE-TS 39” 29” 36” 140lbs (64kg) Shelleybasic by

Summary of the content on the page No. 5

Shelleybasic by Delfield Service & Installation Manual Installation Location Electrical Connection Units represented in this manual are for indoor use only. Be A standard unit is provided with a power cord and grounded sure the location chosen has a floor strong enough to support plug. the total weight of the cabinet and contents. A fully loaded model may weigh as much as 3000 pounds! Reinforce the floor The unit should be plugged into a receptacle with its own circuit as necessary to pro

Summary of the content on the page No. 6

Shelleybasic by Delfield Service & Installation Manual Operation SE-C And SES-C These units are not designed to cool warm food products. There is a switch on the right side of the compressor stand used Items should be placed in the unit pre-cooled at least to to turn the unit on and off. the desired holding temperature, if not slightly colder. In some applications, a gradual warming of product may occur, These units are designed to hold cold food product between particularly at the expos

Summary of the content on the page No. 7

Shelleybasic by Delfield Service & Installation Manual Operation SE-F And SES-F Since it takes time for frost to accumulate initially, the unit Frost tops are designed to maintain an even layer of frost to should be turned on approximately an hour before it is actually pleasantly display desserts and pies. Once turned on, the required. Product should not be placed on the frost top prior to compressor will run continuously. The unit should be turned off turning the unit on, because it ma

Summary of the content on the page No. 8

Shelleybasic by Delfield Service & Installation Manual Maintenance Drain Maintenance - Base regularly. It is recommended that this be done at least every Each unit has a drain located inside the unit that removes three months. If conditions are such that the condenser is totally the condensation from the evaporator coil and routes it to an blocked in three months, the frequency of cleaning should be external condensate evaporator pan. Each drain can become increased. Clean the condenser with

Summary of the content on the page No. 9

Shelleybasic by Delfield Service & Installation Manual Wiring Diagram SE-C, SES-C, SE-ICE1, SES-ICE1, SE-ICE2, SES-ICE2 CONDENSER FAN S C L1 R COMPRESSOR COOLING T'STAT 115V N G Wiring Diagram SE-F, SES-F CONDENSER FAN ON/OFF SWITCH S C L1 R COMPRESSOR 120V N G ™ ® Delfield For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com 9

Summary of the content on the page No. 10

Shelleybasic by Delfield Service & Installation Manual Wiring Diagram SE-H, SES-H PILOT LIGHT (FURNISHED) 1000 W - 120V H1 OR 1000/1200 W - P 208/240 V L1 HEATING ELEMENT L2 H2 LINE WIRES INFINITE CONTROL WITH “OFF” TO ADDITIONAL POSITION FOOD WARMERS AMPERES IN LINE WIRES # OF 120V, 208V, 230V, 208-230V, 3 PHASE WARMERS 1 PHASE 1 PHASE 1 PHASE L1 L2 L3 1 8.3 4.8 5.3 2 16.7 9.6 10.6 3 25 14.4 15.9 14.4/15.9 14.4/15.9 14.4/15.9 4 33.3 19.2 21.3 19.2/21.3 14.4/15.9 19.2/21.3 5 24 26.6 19.2/2

Summary of the content on the page No. 11

Shelleybasic by Delfield Service & Installation Manual Wiring Diagram SE-HC2, SES-HC2 THERMOSTAT CONDENSING UNIT M 120V-1PH-3KW HEATER 3-WAY SWITCH HEATER #1 CONTACTOR L1 HEATER #1 THERMOSTAT HEATER #1 LIMIT SWITCH N Wiring Diagram SE-HC3, SES-HC3, SE-HC4, SES-HC4 THERMOSTAT CONDENSING UNIT M 3-WAY SWITCH HEATER #1 CONTACTOR L1 L2 HEATER #1 THERMOSTAT HEATER #1 LIMIT SWITCH N 240V-1PH-5KW HEATER ™ ® Delfield For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfi

Summary of the content on the page No. 12

Shelleybasic by Delfield Service & Installation Manual Wiring Diagram SE-HC5, SES-HC5, SE-HC6, SES-HC6 L1 L2 N (2) 240V-1PH-5KW HEATERS 3-WAY SWITCH THERMOSTAT CONDENSING UNIT M HEATER #1 HEATER #2 HEATER #1 HEATER #2 CONTACTOR CONTACTOR THERMOSTAT HEATER #1 LIMIT SWITCH HEATER #2 LIMIT SWITCH ™ ® Delfield 12 For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com

Summary of the content on the page No. 13

Shelleybasic by Delfield Service & Installation Manual Condensing Unit Assembly, Cold Pan Units 1 2 3 4 5 8 7 6 1/5 Horse Power, R-134a, Low 1/4 HP, R134A Condensing Unit SE-C2, SES-C2, SE-C3, SES-CE3 Models SE-C4, SES-C4, SE-C5, SES-CE5, SE-C6, SES-CE6 Models Key Delfield Part # Description Delfield Part # Description 1 2183300 Harness, wire, power cord, 8100 1 2183300 Harness, wire, cold pans 2 3526694 Compressor, 1/5 h.p.,115v/60hz 2 3526695 Compressor, 1/4 HP 3 3516047 Thermostat 3 3516047

Summary of the content on the page No. 14

Shelleybasic by Delfield Service & Installation Manual Condensing Unit Assembly 1/4 H.P. R404a, Low SE-HC2, SES-HC2, SE-HC3, SES-HC3, SE-HC4, SES-HC4, SE-HC5, SES-HC5, SE-F2, SES-F2, SE-F3, SES-F3, SE-F4, SES-F4, SE-F5, & SES-F5 Models Key Delfield Part # Description - 000-BN5-0030 Condensing Unit Assembly 1 026-C58-0030 Shroud, 1/5 HP Condenser Coil 2 3516457 Blade, Fan, 7.25” 5 3 2162717 Motor, fan, 9W, 115V, Unit bearing 4 2160020 Guard, Fan, 7.25” 5 3526999 Comp, NF5.5CLX, 115V/60Hz, Danf

Summary of the content on the page No. 15

Shelleybasic by Delfield Service & Installation Manual Condensing Unit Assembly 1/5 H.P. R404a, Low, SE-ICE1, SE-ICE2 Key Delfield Part # Description 1 026-ANM-0030 Baffle, fan, 1/5HP condensing unit 2 3516172 Blade, fan, 5.56, CCW, Lexan, clear 3 2162691 Motor, fan 115V, 50/60, Uppco/Bay 4 031-264-0000 Bracket, fan, motor, freezer 5 3516191 Filter, dryer 6 3526997 Compressor, TF4CLX, 115V/60Hz, Danfoss, SE-ICE1 6 6 3526996 Compressor, 1/5HP, 115/60, R404A, TFS4.5, SE-ICE2 5 7 3516047 Control,

Summary of the content on the page No. 16

Shelleybasic by Delfield Service & Installation Manual Food Well Assembly With Thermostat Control SE-HC, SES-HC Key Delfield Part # Description 1 2194940 Immersion heater 120V 1Ph 3KW, 2 pan 1 2194942 Immersion heater 240V 1Ph 5KW. 3-6 pan 2 026-AO6-0042 Box, control, galv 2 1 3 265-ANQ-003E Front, collar, mounting 4 2193979 Switch, 3 position, 30Amp 5 265-ANS-0001 Cover, control box 6 2194190 Light, pilot, 125V, red 10 7 2194202 Thermostat, electric (heated) 8 3234556 Knob, thermostat control

Summary of the content on the page No. 17

Shelleybasic by Delfield Service & Installation Manual Standard Labor Guidelines To Repair Or Replace Parts On Delfield Equipment Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage. • A maximum of 1-hour is allowed to diagnose a defective component. • A maximum of 1-hour is allowed for retrieval of parts not in stock. • A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed. • Overtime, installation/sta

Summary of the content on the page No. 18

Shelleybasic by Delfield Service & Installation Manual Standard One Year Warranty (One year parts, 90 days labor.) The Delfield Company (“Delfield”) warrants to the Original Purchaser basis, with credit being issued after the part has been received and of the Delfield product (herein called the “Unit”) that such Unit, and all inspected at Delfield’s plant and determined by Delfield to be within this parts thereof, will be free from defects in material and workmanship warranty. under normal us

Summary of the content on the page No. 19

Shelleybasic by Delfield Service & Installation Manual Notes ™ ® Delfield For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com 19

Summary of the content on the page No. 20

™ ® Delfield Mt. Pleasant, MI Covington, TN Thank you for choosing Delfield! Help is a phone call away. Help our team of professional, courteous customer service reps by having your model number and serial number available at the time of your call (800) 733-8829. Model: ____________________ S/N: ___________________ Installation Date: ____________ For a list of Delfield’s authorized parts depots, visit our website at www.delfield.com. ™ ® Delfield 980 S. Isabella Rd., Mt. Pleasant, MI 48858


Alternative user manuals
# User manual Category Download
1 Delfield 407-CA User manual Refrigerator 21
2 Delfield 4400 series User manual Refrigerator 2
3 Delfield 4432N-12M User manual Refrigerator 6
4 Delfield 406-CA User manual Refrigerator 2
5 Delfield 4448N-12 User manual Refrigerator 1
6 Delfield 4448N-1 8M User manual Refrigerator 0
7 Delfield 4460N-12 User manual Refrigerator 4
8 Delfield 4427N-9M User manual Refrigerator 1
9 Delfield 4448N-8 User manual Refrigerator 0
10 Delfield 4464N User manual Refrigerator 0
11 Delfield 4460N-12M User manual Refrigerator 0
12 Delfield 4460N-24M User manual Refrigerator 0
13 Delfield 4460N-8 User manual Refrigerator 0
14 Delfield 4460N-18M User manual Refrigerator 1
15 Delfield 4472N-12 User manual Refrigerator 0
16 2JANE Surround Sound System HTS-GS1 User manual Refrigerator 4
17 3Com Phaser 7750 User manual Refrigerator 1
18 3Com iQ 10 User manual Refrigerator 0
19 3Com PowerDual iQ 10 iQ 10C User manual Refrigerator 1
20 3Com PowerDual iQ 10 iQ 10P User manual Refrigerator 2