Summary of the content on the page No. 1
500 Series
Service and Installation Manual
Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all
components immediately. See page 2.
Effective May 2003
IMPORTANT INFORMATION
READ BEFORE USE
PLEASE SAVE THESE INSTRUCTIONS!
Summary of the content on the page No. 2
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual CONTENTS SERIAL NUMBER LOCATION RECEIVING & INSPECTING EQUIPMENT..............................2 The Serial number on all 500 Series units is located on the SPECIFICATIONS ..................................................................3 rear of the unit, near the ON/OFF switch. PRESSURE CONTROL SETTINGS.........................................5 Always have the serial number of you
Summary of the content on the page No. 3
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual 500 SERIES SPECIFICATIONS MODEL DELFIELD VOLTS/HERTZ AMPS NUMBER PART # PHASE (includes lights & fan) Dry Storage Display Cases 537-CD 078-5371
Summary of the content on the page No. 4
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual INSTALLATION: 500 CD, CR, CRR & OR Location Plumbing To meet NSF standards, all units must be sealed Self-contained models are standard with a condensate to the floor. evaporator. If the evaporator fails, the unit’s drain must have an outlet to an appropriate drainage area or container. Moisture collecting from improper drainage Be sure the location chosen has a floor strong enoug
Summary of the content on the page No. 5
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual CONTROL SETTINGS: 500 CR & OR Pressure Control The temperature is controlled by an adjustable pressure control located in the machine compartment. An adjustable control has the word COLDER near the knob, with an arrow to indicate the adjustment direction. These controls are field adjustable and do not require a service agent. If you have any questions, feel free to contact th
Summary of the content on the page No. 6
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual INSTALLATION: 500 CH Installation should be done by personnel Leveling certified and licensed to install and maintain A level cabinet looks better and will perform better because electrical appliances. the drain pan will drain properly, the doors will line up with the frames properly, and the cabinet will not be subject to undue strain. Location Be sure the location chosen has a
Summary of the content on the page No. 7
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual WIRING: 500 CR WIRING: 500 OR NEUTRAL NEUTRAL 7 6 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
Summary of the content on the page No. 8
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual WIRING: 500 CD WIRING: 500 CH BLK RED BLK WHT RED RED WHT BLK BLK BLK BLK WHT P P P P WHT J P L L P L L P L L P L L 1 2 1 2 1 2 1 2 208V 208V 208V 120V H H H H H H H H 1 1 1 1 2 2 2 2 HEATED SHELF 9 8 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfie
Summary of the content on the page No. 9
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual REPLACEMENT PARTS LIST FOR 537-CD DELFIELD KEY QUANTITY PART# DESCRIPTION 1 1 001-3133 mirror, acrylic, RH, 500-CD 2 1 001-3134 mirror, acrylic, LH, 500-CD
Summary of the content on the page No. 10
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual REPLACEMENT PARTS LIST FOR 561-CD DELFIELD KEY QUANTITY PART# DESCRIPTION 1 1 001-3133 mirror, acrylic, RH, 500-CD 2 1 001-3134 mirror, acrylic, LH, 500-CD
Summary of the content on the page No. 11
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual REPLACEMENT PARTS LIST FOR 537CR/CRR DELFIELD KEY QUANTITY PART# DESCRIPTION 1 1 001-3131 mirror, acrylic, RH, 500-CR 2 1 001-3132 mirror, acrylic, LH, 500
Summary of the content on the page No. 12
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual REPLACEMENT PARTS LIST FOR 561-CR/CRR DELFIELD KEY QUANTITY PART# DESCRIPTION 1 1 001-3133 mirror, acrylic, RH 2 1 001-3132 mirror, acrylic,
Summary of the content on the page No. 13
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual REPLACEMENT PARTS LIST FOR 549-CH DELFIELD 15 KEY PART# DESCRIPTION 1 323-4055 door set, 49” curved glass 2 345-5439 glass, curved, 1” insulated, 47” 3
Summary of the content on the page No. 14
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual REPLACEMENT PARTS LIST FOR 573-CH 15 DELFIELD KEY PART# DESCRIPTION 1 323-4069 door set, 73” curved glass 2 345-5443 glass, curved, 1” insulated, 71” 1 3
Summary of the content on the page No. 15
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual FLUORESCENT LIGHT DELFIELD 1 7 KEY PART# DESCRIPTION 1 SMK00571 cap, end, top mtg, pigtail, -rem. 2 SMK00572 cap, end, top mtg, blank, -rem. 8 3 170-104
Summary of the content on the page No. 16
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual Door Assembly DELFIELD KEY PART# DESCRIPTION 323-7490 complete assembly, 537-CD/CR/CRR 323-4697 complete assembly, 549-CD/CR/CRR 323-4055
Summary of the content on the page No. 17
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual COMPRESSOR/COIL ASSEMBLY 537/549/561-CR/CRR DELFIELD KEY PART# DESCRIPTION 1 010-1916 coil pan assembly 2 001-5251 bracket, fan mounting 001-5417 bracket, fan mounting (537-CR) 3 219-3919 switch, toggle, SPST 4 219-3903 ballast, rapid start (549 & 537-CR) 219-3904 ballast, rapid start (561) 5 219-3942 control, SPST 219-3927 control, SPST (537-CR) 6 351-6231 eva
Summary of the content on the page No. 18
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual DELFIELD FOOD WELL (DFW) ASSEMBLY: WITH INFINITE CONTROL For 500-CH Heated Units DELFIELD KEY PART# DESCRIPTION 10 XMK00106 Complete assembly, infinite w/o drain 1 GMK00061 Defle
Summary of the content on the page No. 19
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual REPLACEMENT PARTS LIST — NOT SHOWN ON EXPLODED VIEWS DELFIELD DESCRIPTION DELFIELD DESCRIPTION PART# PART#
Summary of the content on the page No. 20
500 Series Display Cases Service and Installation Manual 500 Series Display Cases Service and Installation Manual STANDARD LABOR GUIDELINES TO REPAIR OR REPLACE PARTS ON DELFIELD EQUIPMENT Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage. • A maximum of 1-hour is allowed to diagnose a defective component. • A maximum of 1-hour is allowed for retrieval of parts not in stock. • A maximum travel distance of 100 miles round trip and