Summary of the content on the page No. 1
Questions? Comments? call SENCO's toll-free Action-line: 1-800-543-4596 or e-mail: toolprof@senco.com
PC 1010 Electric Air Compressor
Senco Products, Inc.
8485 Broadwell Rd.
Cincinnati, OH 45244
Operating Instructions
© 2002, 2008 by Senco Products, Inc.
PC1010 Revised February 1, 2008
(Replaces 10/18/07)
Warnings for the safe use of this compressor are included in this manual.
Des mises en garde pour une utilisation en toute sécurité de ce compresseur
sont incluses dans ce manuel.
En este manu
Summary of the content on the page No. 2
TABLE OF CONTENTS INTRODUCTION ................................................................... 3 SAFETY INSTRUCTIONS...................................................... 3 INSPECTION ......................................................................... 3 SAFETY WARNINGS .........................................................4-7 ELECTRICAL ................................................................ 4 EXPLOSION OR FIRE.................................................. 5 BURSTING .
Summary of the content on the page No. 3
INTRODUCTION ® Congratulations on the purchase of your new SENCO Air Compressor! You can be assured your SENCO Air Compressor was constructed with the highest level of precision and accuracy. Each component has been rigorously tested by technicians to ensure the quality, endurance and performance of this air compressor. This operator’s manual was compiled for your benefit. By reading and following the simple safety, installation and operation, and maintenance steps described in this manual, yo
Summary of the content on the page No. 4
SAFETY WARNINGS READ ALL SAFETY WARNINGS BEFORE USING AIR COMPRESSOR HAZARD POTENTIAL CONSEQUENCE PREVENTION Serious injury or death could occur if Make sure the air compressor is the air compressor is not properly plugged into a properly grounded RISK OF grounded. Your air compressor is outlet which provides correct ELECTRIC SHOCK powered by electricity and may cause voltage and adequate fuse OR electric shock or electrocution if not protection. ELECTROCUTION used properly. Electrical shock may
Summary of the content on the page No. 5
SAFETY WARNINGS SAFETY WARNINGS READ ALL SAFETY WARNINGS BEFORE USING AIR COMPRESSOR READ ALL SAFETY WARNINGS BEFORE USING AIR COMPRESSOR PREVENTION HAZARD POTENTIAL CONSEQUENCE PREVENTION POTENTIAL CONSEQUENCE HAZARD RISK OF Always operate air compressor in a Serious injury or death could occur if Make sure the air compressor is Serious injury or death may occur from EXPLOSION OR FIRE well ventilated area free of normal electrical sparks in motor and the air compressor is not properly plugged i
Summary of the content on the page No. 6
SAFETY WARNINGS READ ALL SAFETY WARNINGS BEFORE USING AIR COMPRESSOR HAZARD POTENTIAL CONSEQUENCE PREVENTION RISK TO Serious injury or death could occur Never inhale air from the air BREATHING from inhaling compressed air. The air compressor either directly or from a stream may contain carbon monoxide, breathing device connected to the air toxic vapors or solid particles. compressor. Sprayed materials such as paint, paint Operate air compressor only in a well solvents, paint remover, insecticide
Summary of the content on the page No. 7
SAFETY WARNINGS READ ALL SAFETY WARNINGS BEFORE USING AIR COMPRESSOR HAZARD POTENTIAL CONSEQUENCE PREVENTION RISK FROM Risk of bodily injury from moving parts. Always turn off air compressor. MOVING PARTS This air compressor cycles Bleed pressure from the air hose automatically when the pressure and unplug from electrical outlet switch is in the “On/Auto” position. before performing maintenance. All repairs to the air compressor should be made by an Authorized Service person. Never assume
Summary of the content on the page No. 8
COMPRESSOR FEATURES 8 12 11 1 4 10 7 5 9 2 6 13 3 1 Motor/Pressure Switch 2 Thermal Overload / Reset 3 Air Intake Filter 4 Air Compressor Pump 5 Safety Relief Valve 6 Air tank drain valve 7 Tank Pressure Gauge 8 Outlet Pressure Gauge 9 Pressure Regulator 10 Discharge Line 11 115 Volt Electric Power Cord 12 Ventilation Openings / Protective Shroud 13 Quick Disconnect 8
Summary of the content on the page No. 9
COMPRESSOR FEATURES 1) MOTOR/PRESSURE SWITCH: This switch is used to start or stop the air compressor. Moving the switch to the (On) position will provide automatic power to the pressure switch which will allow the motor to start when the air tank pressure is below the factory set cut-in pressure. When in the (On) position, the pressure switch stops the motor when the air tank pressure reaches the factory set cut-out pressure. For safety purposes, this switch also has a pressure release 1 valve
Summary of the content on the page No. 10
PREPARATION INITIAL SET-UP: 1. Read safety warnings before setting-up air compressor. LOCATION: CAUTION In order to avoid damaging the air compressor, do not incline the air compressor transversely or longitudinally more than 10º. 1. Place air compressor at least 12 inches away from obstacles that may prevent proper ventilation. Do not place air compressor in an area: -where there is evidence of oil or gas leaks. -where flammable gas vapors or materials may be present. WARNING Serious inju
Summary of the content on the page No. 11
OPERATION PRE-START CHECKLIST: 1. Remove any moisture in the air compressor tank. Remove excessive pressure by pulling on the safety relief valve ring or with an air tool, then open the air tank drain valve in the bottom of the air tank. Close tightly when drained. WARNING: Risk of bodily injury. NEVER attempt to open the drain valve when more than 10 PSI of air pressure is in the air tank! 2. Make sure the air compressor Motor Switch is in the “OFF” position. 3. Make sure all safety valves
Summary of the content on the page No. 12
TROUBLESHOOTING Symptom 1. Motor will not run or restart. Power cord not plugged in. Plug cord into grounded outlet. position. Motor/Pressure switch in “OFF” position. Move switch to “ON” Fuse blown or circuit breaker has tripped. Replace fuse or reset circuit breaker. Check for proper fuse amperage. Check for low voltage conditions. Disconnect any other electrical appliances from circuit or operate air compressor on its own branch circuit. Wrong gauge wire or length of extension Check chart o
Summary of the content on the page No. 13
TROUBLESHOOTING Symptom 5. Air leaks from safety relief valve. REMEDY PROBABLE CAUSE Operate safety relief valve manually by pulling on ring. Possible defective safety relief valve. If it still leaks, it should be replaced. Defective motor/pressure switch. Replace. Excessive air tank pressure. Symptom 6. Air leaks at fittings. REMEDY PROBABLE CAUSE Tighten fittings where air can be heard escaping. Check Fittings are not tight enough. fittings with soapy water solution. Do not overtighten. Sympto
Summary of the content on the page No. 14
SPECIFICATIONS Model # PC 1010 Motor Horsepower 1 HP (peak) 1/2 HP (Running) Voltage 115 Amperage 4 Hz. 60 Phase Single RPM 3400 Compressor Pump Number of Cylinders 1 Compression Stage 1 Crankcase Aluminum Bearings Ball Cylinder Aluminum Valves Reed-Single Head Aluminum Filter Insert Motor/Pressure Switch Setting Cut-out 125 PSI Cut-in 95 PSI Controls Start / Stop Air tank 1 gallon Capacity Performance 1.4 CFM Air Displacement 1.0 CFM @ 40 PSI 0.7 CFM @ 90 PSI 0.6 CFM @ 100 PSI Maximum P
Summary of the content on the page No. 15
Limited Warranty SENCO® Pneumatic, DuraSpin®, Cordless Tools & Compressors Senco Products, Inc. (“SENCO”) designs and constructs its products using the highest standards of material and workmanship. SENCO warrants to the original retail purchaser that the following products will be free from defects in material or workmanship for the warranty period specified below: SENCO® XP Series-Red Cap SENCO PRO Series SENCO Compressors Five years One year One year SENCO® XP Series-Black Cap SENCO D
Summary of the content on the page No. 16
SM M E M B E R PC1010 1/2 HP Electric Air Compressor Parts Reference Guide Part No. Description 3B11DC02A Exaust Valve Assembly 3201068 Cylinder 3B34DC02 Rod Assembly 3B11DC02A 2E2505A Circuit Breaker 2Y30QJ03 Air Filter Set 3201068 2E27010F250V Condensor 2406018 Pressure Relief Valve PC0057 Pressure Gauge 2408008RN Regulator 3B34DC02 PC0503 Quick Coupler 2E2505A 2Y30QJ05 Unloading Tube Set 3B202190 Unloading Tube 2E21045TB Pressure Switch 2414033A Check Valve 2Y30QJ03 2405011 Dr
Summary of the content on the page No. 17
Questions? Commentaires? appel gratuit de SENCO au 1-800-543-4596 ou courriel à toolprof@senco.com Compresseur d'aire électrique PC1010 Senco Products, Inc. 8485 Broadwell Rd. Cincinnati, OH 45244 Notice technique d'utilisation © 2004, 2008 by Senco Products, Inc. PC1010 Révision du 1 Février 2008 (remplace la version 1/12/05) Des mises en garde pour une utilisation en toute sécurité de ce compresseur sont incluses dans ce manual. 1
Summary of the content on the page No. 18
TABLE DES MATIÈRES INTRODUCTION ................................................................... 3 INSTRUCTION DE SÉCURITÉ .............................................3 INSPECTION ......................................................................... 3 ........................... MISES EN GARDE DE SÉCURITÉ 4-7 ÉLECTRICITÉ ............................................................... 4 ....................................... EXPLOSION OU INCENDIE 5 ÉCLATEMEN T ...................
Summary of the content on the page No. 19
INTRODUCTION ® Félicitations pour votre achat de notre nouveau compresseur d’air SENCO ! Vous pouvez être assuré que votre compresseur d’air SENCO a été construit avec le plus haut niveau de précision et d’exactitude. Chaque composant a été rigoureusement testé par des techniciens pour constituer la qualité, l’endurance et la performance de ce compresseur d’air. Ce manuel d’utilisation a été composé pour vous servir. En lisant puis en appliquant les étapes simples décrites dans de manuel de
Summary of the content on the page No. 20
MISES EN GARDE DE SÉCURITÉ LISEZ TOUTES LES MISES EN GARDE DE SÉCURITÉ AVANT D’UTILISER LE COMPRESSEUR D’AIR DANGER CO NSEQUENCES POTENTIELLES PREVENTION Assurez-vous que compresseur d’air est RISQUE DE Des blessures graves ou mortelles bien branché sur une prise secteur COMMOTION ÉLECTRIQUE peuvent arriver si le compresseur convenablement reliée à la terre, qui fournit OU D’ÉLECTROCUTION n’est pas mis à la terre de façon la tension correcte, et qui est protégée en convenable. Votre com