Makita MAC1000 user manual

User manual for the device Makita MAC1000

Device: Makita MAC1000
Category: Air Compressor
Manufacturer: Makita
Size: 3.04 MB
Added : 7/7/2013
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Makita MAC1000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Makita MAC1000.

For your convenience

If looking through the Makita MAC1000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Makita MAC1000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Makita MAC1000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Makita MAC1000 User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Makita MAC1000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Makita MAC1000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Oilless, Single-Stage, Direct-Drive, Electric Air Compressor
Sans I'huile, d'une seule etape, B prise directe, compresseur d'air 6lectrique
Sin aciete, de una sola etapa, de mando directo, compresore de aire elktrico
Specification Chart Tableau des specifications Cuadro de especificaciones
TANK CAPACITY VOLTAGEI KICK-IN KICK-OUT
MODEL NO.
GALLONS AMPSIPHASE PRESSURE PRESSURE
(MOD~LE)
(CAPACITE DU (TENSION/ CFM CFM (PRESSION (PRESSION DE
(MODELO) Rl%ERVOIR - UTRES) AMPSlPHASE) (Ilmin) (I

Summary of the content on the page No. 2

TABLE OF CONTENTS TABLE DES MATIERES INDICE TABLE OF CONTENTS SAFETY GUIDELINES ........................... 3 Shutdown ................................. 12 OVERVIEW ................................... 6 MAINTENANCE ............................... 13 Basic Air Compressor Components ............. 6 Draining the Tank .......................... 13 COMPRESSOR CONTROLS ...................... 7 Cleaning the Air Filter ....................... 13 ELECTRICAL POWER REQUIREMENTS ............ 8 Che

Summary of the content on the page No. 3

INTRODUCTION INTRODUCTION INTRODUCCION Read this manual carefully before operating or servicing this air compressor to familiarize yourself with proper safety, operation and D' mamtenance procedures. FAILURE TO COMPLY WITH INSTRUCTIONS IN THIS MANUAL COULD RESULT IN PERSONAL INJURY, PROPERTY DAMAGE, AND/OR VOIDING OF YOUR WARRANTY. COLEMAN POWERMATE COMPRESSORS WILL NOT BE LIABLE FOR ANY DAMAGE BECAUSE OF FAILURE TO FOLLOW THESE INSTRUCTIONS. Following the instructions in this manual will pr

Summary of the content on the page No. 4

regulated so as to never exceed the maximum pressure A WARNING - A POTENTIAL HAZARD THAT COULD rating of the W. CAUSE SERIOUS INJURY OR LOSS OF LIFE. 5. High temperatures and moving parts are present under the 1. Do not weld on the air tank of this compressor. Welding on shroud. To prevent bums or other inuries, 00 NOT operate the air compressor tank can severely impair tank strength with the shroud removed. Allow the compressor parts to cool and cause an extremely hazardous conditon. W

Summary of the content on the page No. 5

3. Fasten the compressor down securely if transporting A CAUTION - A POTENTIAL HAZARD THAT MAY is necessary. Pressure must be released from the CAUSE MODERATE INJURY OR DAMAGE TO EQUIPMENT. tank before transporting. 1. Drain the moisture from the tank on a daily basis. A 4. Protect the air hose and electric cord from damage clean, dry tank will help prevent corrosion. and puncture. Inspect them weekly for weak or worn spots, and replace if necessary. 2. Pull the pressure relief valve r

Summary of the content on the page No. 6

OVERVl EW VUE D’ENSEMBLE RESUMEN GENERAL D Oilless air compressors are factory lubricated for life, and do not require any oil. Bask Air Compressor Components The basic components of the air compressor are the electric motor, pump, pressure switch, and tank. The electric motor (see A) powers the pump. A CAUTION The electric motor is equipped with an overload protector and an automatic reset. If the motor becomes overheated, the overload protector will shut it down to prevent damage to

Summary of the content on the page No. 7

COMPRESSOR CONTROLS COMMANDES DU COMPRESSEUR CONTROLES DEL COMPRESOR WOFF switch (see A) E - Outlet pressure gauge This switch tums on the compressor. It is operated manually, but when Sortie de manometre de pression in the ON position, it allows the compressor to start up or shut down Salida de manometro de presi6n automatically, without warnlng. upon air demand. ALWAYS operate this switch to OFF when the compressor is not being used, and before F - Air line connection unplugging th

Summary of the content on the page No. 8

ELECTRICAL POWER REQUIREMENTS SPECIFICATIONS DU COURANT ELECTRIQUES REQUERIMIENTOS DE ALIMENTACION ELECTRICA D ELECTRICAL WIRING CABLAGE ELECTIQUE Refer to the air compressor's serial label for the unit's voltage and Pour savoir quelles sont les normes dintensite et de tension de amperage requirements. I'appareil, r6fBrez-vous A IUtiquette du num6ro de sene du compresseur dair. Use a dedicated circuit Utiiisez un circuit &par6 For best performanco and reliable starting, the air comp

Summary of the content on the page No. 9

WARNING: Improper installation of the grounding D A plug can result in a risk of electric shock. If repair or replacement of the cord or plug is necessary, do not conned CABLEADO ELECTRIC0 the grounding wire to either Rat terminal. t he wire Refierase al r6tulo del nljmero de sene del compresor de aire para isulation having an outer surface that is green with or without yellow conocer 10s requerimientos de voltaje y amperaje de la unidad. tripes is the grounding wire. Use un clrculto ex

Summary of the content on the page No. 10

BREAK-IN OF THE PUMP-RODAGE DE LA POMPE-MARCHA INlClAL DEL BOMBA D 1. Operate the ONIOFF switch to OFF (see A). 2. Open the petcock (see B). 3. Plug in the power cord. Note: If the unit does not operate properly, SHUT DOWN IMMEDIATELY, and contact your nearest Service Center. 4. Operate the ON/OFF switch to ON (see C). Allow the compressor to run for 30 minutes, to break in the internal parts. 5. Operate the ON/OFF switch to OFF. Unplug the power cord. m 1. Reglez I'interrupteur de

Summary of the content on the page No. 11

OPERATING INSTRUCTIONS-MODE D’EMPLOI-INSTRUCCIONES OPERATWAS D DAl LY STARTUP 1. Operate the ON/OFF switch to OFF (see A). 2. Close the tank petcock (see B). 3. Plug in the power cord. 4. Operate the ON/OFF switch to ON (see C). Note: When adjusting from a higher to a lower pressure, turn the knob counterclockwise past the desired setting, then turn clockwise to reach the desired pressure. Adjust the air pressure regulator (see D) to the working 5. pressure of the tool being used.

Summary of the content on the page No. 12

D SHUTDOWN 1. Operate the ONIOFF switch to OFF (see A). 2. Unplug the power cord. 3. Relieve all pressure in the tank through the outlet hose. You can also pull the relief valve ring (see B) and keep it open to relieve pressure in the tank. A CAUTION: Debris which becomes airborne by escaping air and moisture may cause eye injury. 4 Wear safety goggles when opening petcock. 4. Tip the compressor so the petcock are at the bottom of the tank. Then open the petcock (see C) to allow moi

Summary of the content on the page No. 13

MAINTENANCE ENTRETIEN MANTENIMIENTO D A WARNING To avoid personal injury, always shut off and unplug the compressor and relieve all air pressure from the system before performing any service on the air compressor. Regular maintenance will ensure trouble-free operation. Your electric powered air compressor represents highquality engineering and construction; however, even high-quality machinery requires periodic maintenance. The items listed below should be inspected on a regular basis.

Summary of the content on the page No. 14

LD D Verificaci6n de la valvula de alivio Checking the relief valve 10s dias para asegurarse de Tire de la valvula de alivio todos Pull the relief valve daily to ensure that it is operating properly que est6 funcionando correctamente y para eliminar cualquier and to clear the valve of any possible obstructions. obstrucci6n posible de la misma. Storage Almacenamiento Before storing the compressor for a prolonged period, use an Antes de almacenar el compresor durante periodos air blow

Summary of the content on the page No. 15

TROUBLES) OOTING CHART Note: Troubleshooting problems may have similar causes and solutions. ]PROBLEM POSSiBLE CAUSE Tank petcock is open Close petcock. Fittings leak Check fittin s with soa water. Tighten or reseal leaking fittings. or DO NOT O~ERTIGHTPN. Compressor does not Restricted air intake Clean or replace air filter element. stop Prolonged excessive use of air Decrease amount of air used. Compressor not large enough Check air requjrement of accessory. If it is higher than CFM a

Summary of the content on the page No. 16

lotor will not run Tank pressure exceeds preset Motor will start automatically when tank pressure drops below pressure switch limit kick-in pressure of pressure switch. Motor overload protection has Let motor cool off, and overload switch will automatically reset. tripped This may take several minutes. Fuse Mown or circuit breaker Replace blown fuse or reset circuit breaker. Do not use fuse tripped or circuit breaker with higher rating than that specified for your branch circuit. 0 Check

Summary of the content on the page No. 17

DEPANNAG E m Remarque : Les problemes de depannage peuvent avoir des causes et des solutions similaires. CAUSE POSSIBLE SOLUTION Basse pression w pas Robinet de Durae ouvert Fermez le robinet de purge. assea d'alr Fuite de raccords VBrifiez les raccords avec de I'eau savonneuse. Resserrez ou Btancheifiez de nouveau les raccords qui ont des fuites. NE SERREZ PAS TROP. ~~ Admission dair colmatee Nettoyez ou remplacez le filtre a air. I Utilisation excessive et pro long& Reduisez la qua

Summary of the content on the page No. 18

Fuites d'air du Pikes internes du r6gulateur Nettoyez ou remplacez le regulateur ou les pieces internes. regulateur, ou le sales ou endommagees reguiateur ne contrbie I pas la pression Tension insuffisante Fwmissez une puissance adequate. Soupape de decharge de Remplacez la soupape de purge. soupape de purge defectueuse ~~~ La pression dans le rtSservoir depasse la pression normale de fonctionnement Remplacez I'intermpteur de pression. lntermpteur de pression coin06 en position QN"

Summary of the content on the page No. 19

CUADRO DE DETECCION DE FALLOS Nota: Los problemas de detecclon de fallos pueden tener causa8 y soluclones slmliares. CAUSA POSlBLE SOLUCION ROBLEMA ~ resi6n baja o no hay Vdlvula de descarga esta abiirta Cierre la vhlvula de descarga. ~ ufidente aire Hay fugas en los accesorios ue 10s accesorios con agua jabonosa. Auste o vuelva a os accesorios que tengan fugas. NO AJUSTE 0 DEMASIADO. I compresor no se etlene Entrada de aire restrinaida Limpie o reemplace el elemento del filtro de a

Summary of the content on the page No. 20

Se Se detiene detiene el el motor motor Voltaje bajo Suministre la energia adecuada. Valvula de alivio del intemptor de Reemplace el valvula de purga. presi6n defecbosa El El motor motor no no fundona fundona El motor anancara automlticamente cuando la presi6n del tanque La presi6n del tanque es mayor que el limite prefijado del disminuye por debajo de la presi6n de conexi6n del intemptor de presi6n. intemptor de presi6n Ha saltado el interruptor de Permita que se enfria el motor y el in


Alternative user manuals
# User manual Category Download
1 Makita MAC1200 User manual Air Compressor 2
2 Makita AMPSI PRESSURE MAC3000 User manual Air Compressor 1
3 Makita MAC5200 User manual Air Compressor 126
4 Makita MAC5500G User manual Air Compressor 1
5 Makita MAC500 User manual Air Compressor 2
6 Makita MAC2200 User manual Air Compressor 7
7 Makita MAC700 User manual Air Compressor 128
8 Makita MAC8000 User manual Air Compressor 0
9 Makita MAC2400 User manual Air Compressor 58
10 Directed Electronics 350HV User manual Air Compressor 5
11 12Volt 12V6CF User manual Air Compressor 2
12 Alesis 3630 User manual Air Compressor 260
13 AllTrade 835533 User manual Air Compressor 1
14 AllTrade 835579 User manual Air Compressor 3
15 AllTrade 830211 User manual Air Compressor 4