Hitachi EC 6C user manual

User manual for the device Hitachi EC 6C

Device: Hitachi EC 6C
Category: Air Compressor
Manufacturer: Hitachi
Size: 1.05 MB
Added : 2/5/2014
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Hitachi EC 6C. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Hitachi EC 6C.

For your convenience

If looking through the Hitachi EC 6C user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Hitachi EC 6C on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Hitachi EC 6C to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Hitachi EC 6C User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Hitachi EC 6C but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Hitachi EC 6C. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

English
POWER TOOLS
INSTRUCTION MANUAL AND SAFETY INSTRUCTIONS FOR AIR COMPRESSOR
MANUEL D’UTILISATION ET CONSIGNES DE SÉCURITÉ DU COMPRESSEUR
MANUAL DE INSTRUCCIONES Y INSTRUCCIONES DE SEGURIDAD PARA EL COMPRESOR DE AIRE
MODEL
MODÈLE
EC 6B EC 6C EC 12 EC 16
MODELO
EC6B EC6C
EC12 EC16
WARNING
Improper and unsafe use of this compressor can result in death or serious bodily injury!
This manual contains important information about product safety.
Please read and understand this manual before opera

Summary of the content on the page No. 2

English — CONTENTS — English Page Page IMPORTANT INFORMATION ...............................3 OPERATION AND MAINTENANCE MEANINGS OF SIGNAL WORDS ........................3 NAME OF PARTS ..................................................8 SPECIFICATIONS ..................................................9 SAFETY ACCESSORIES ......................................................9 IMPORTANT SAFETY INSTRUCTIONS APPLICATIONS .....................................................9 FOR USE OF THE COMPRESS

Summary of the content on the page No. 3

English IMPORTANT INFORMATION Read and understand all of the operating instructions, safety precautions and warnings in the Instruction Manual before operating or maintaining this compressor. Most accidents that result from compressor operation and maintenance are caused by the failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing a potentially hazardous situation before it occurs, and by observing appropriate safety procedures. Basic safety precau

Summary of the content on the page No. 4

English SAFETY IMPORTANT SAFETY INSTRUCTIONS FOR USE OF THE COMPRESSOR WARNING: Death or serious bodily injury could result from improper or unsafe use of compressor. To avoid these risks, follow these basic safety instructions: READ ALL INSTRUCTIONS Compressor produces sparks during operation. 1. NEVER TOUCH MOVING PARTS. Never use compressor in sites containing lacquer, Never place your hands, fingers or other body parts paint, benzine, thinner, gasoline, gases, adhesive near the compressor’s

Summary of the content on the page No. 5

English Have defective pressure switches replaced by 24. USE ONLY GENUINE HITACHI REPLACEMENT PARTS. authorized service center. Replacement parts not manufactured by Hitachi may Do not use compressor if switch does not turn it on void your warranty and can lead to malfunction and and off. resulting injuries. Genuine Hitachi parts are available from your dealer. 17. NEVER USE COMPRESSOR FOR APPLICATIONS OTHER THAN THOSE SPECIFIED. 25. DO NOT MODIFY THE COMPRESSOR. Never use compressor for applica

Summary of the content on the page No. 6

English SAFETY — Continued GROUNDING INSTRUCTIONS This compressor should be grounded while in use to protect the operator from electric shock. The compressor is equipped with a three-conductor cord and three-prong grounding type plug to fit the proper grounding type receptacle. The green (or green and yellow) conductor in the cord is the grounding wire. Never connect the green (or green and yellow) wire to a live terminal. If your unit is for Cover of Grounded Ground use on less than 150 volts,

Summary of the content on the page No. 7

English WARNING: Avoid electrical shock hazard. Never use this compressor with a damaged or frayed electrical cord or extension cord. Inspect all electrical cords regularly. Never use in or near water or in any environment where electric shock is possible. SAVE THESE INSTRUCTIONS AND MAKE THEM AVAILABLE TO OTHER USERS OF THIS TOOL! — 7 —

Summary of the content on the page No. 8

English OPERATION AND MAINTENANCE NOTE: The information contained in this Instruction Manual is designed to assist you in the safe operation and maintenance of the compressor. Some illustrations in this Instruction Manual may show details or attachments that differ from those on your own compressor. NAME OF PARTS Intake filter Knob of the pressure switch Knob of the pressure switch Intake filter Head Knob of the pressure reducer Knob of the pressure reducer Dipstick Joint Joint Tank Tank Drain c

Summary of the content on the page No. 9

English SPECIFICATIONS Model EC6B EC6C EC12 EC16 Motor Single-Phase, Induction Motor Power Source Single-Phase, 115V AC 60Hz 1 HP 1 HP 2 HP 2 1/2 HP Input (0.75 KW) (0.75 KW) (1.49 KW) (1.87 KW) Current 7.8A 10.05A 13.5A 13.5A 3.3 gal. 3.3 gal. 4 gal. 5 gal. Tank Capacity (12.5 ltr) (12.5 ltr) (15.1 ltr) (18.9 ltr) 125 PSI 125 PSI 125 PSI 145 PSI Maximum Pressure (8.6 bar) (8.6 bar) (8.6 bar) (10.0 bar) at 40 PSI 3.2 CFM 3.0 CFM 4.2 CFM 4.9 CFM (2.8 bar) (91 ltr/min) (85 ltr/min) (119 ltr/min) (

Summary of the content on the page No. 10

English Dipstick PRIOR TO OPERATION 1. Power source Ensure that the power source to be utilized conforms to the power source requirements specified on the product nameplate. 2. Power switch MAX. Ensure that the knob of the pressure switch is in the MIN. “OFF” position. If the plug is connected to a EC6B receptacle while the knob is in the “AUTO” position, (EC16) () EC12 the compressor will start operating immediately and Fig. 3 can cause serious injury. When the oil volume is insufficient, refer

Summary of the content on the page No. 11

English Knob of the pressure reducer Reset switch of thermal protector Knob of the pressure switch Joint Pressure gauge Fig. 4 (EC6B) (EC6C) 3. Shutdown (1) Turn the knob of the pressure switch to “OFF”. (Fig. 1) Reset switch of thermal protector (2) Unplug the plug from power source. (3) Open the drain cock located at the lower part of the tank (Fig. 5). Drain cock (EC16) (EC12) Tank Fig. 5 Fig. 6 MAINTENANCE 4. About the thermal protector This item is not necessary if your compressor is not eq

Summary of the content on the page No. 12

English Filter element Intake filter EC6B () EC6C Drain cap Filter element Intake filter EC6B () EC12 (EC12) Drain cap Filter element (EC16) Fig. 8 Intake filter (EC16) Pour oil into the hole of the dipstick. Fig. 7 To the level indicated on the dipstick (Fig. 3). For oil replacement, follow the table below. NOTE: OIL TYPE Replace the filter element when it becomes dirty. SAE 5W50 SYNTHETIC OIL (–20°+120°F) For both summer and winter use 2. Draining tank SAE 10W40 MULTI-GRADED OIL (+50°+120°F) D

Summary of the content on the page No. 13

Français INFORMATIONS IMPORTANTES Lire attentivement toutes les instructions de fonctionnement, les consignes de sécurité et les mises en garde contenues dans ce manuel avant de faire fonctionner le compresseur ou de procéder à son entretien. La majorité des accident résultant de l’utilisation ou de l’entretien du compresseur sont dus au non respect des consignes et règles de sécurité élémentaires. En identifiant à temps les situations potentiellement dangereuses et en observant les consignes de

Summary of the content on the page No. 14

Français SÉCURITÉ CONSIGNES DE SÉCURITÉ IMPORTANTES POUR L’UTILISATION DU COMPRESSEUR AVERTISSEMENT: Une utilisation du compresseur de manière incorrecte ou qui ne respecte pas les consignes de sécurité peut entraîner la mort ou de graves blessures. Pour éviter tout danger, observer ces consignes élémentaires de sécurité: BIEN LIRE TOUTES LES INSTRUCTIONS 1. NE JAMAIS TOUCHER AUX PIÈCES MOBILES. 9. SE SOUCIER DE L’ENVIRONNEMENT DE TRAVAIL. Ne jamais approcher les mains, les doigts ou aucune Ne p

Summary of the content on the page No. 15

Français 17. UTILISER LE COMPRESSEUR EXCLUSIVEMENT POUR 24. UTILISER EXCLUSIVEMENT DES PIÈCES DE LES APPLICATIONS SPÉCIFIÉES DANS LE MANUEL RECHANGE HITACHI D’ORIGINE. D’UTILISATION. L’utilisation de pièces de rechange autres que celles fabriquées par Hitachi peut entraîner l’annulation de la Ne jamais utiliser le compresseur pour des utilisations garantie et être la cause d’un mauvais fonctionnement autres que celles spécifiées dans le manuel. et des blessures en résultant. Les pièces d’origine

Summary of the content on the page No. 16

Français SÉCURITÉ (suite) INSTRUCTIONS DE MISE À LA TERRE Ce compresseur devra être mis à la terre pendant le fonctionnement de manière à protèger l’opérateur des décharges électriques. Le compresseur est doté d’un cordon à trois conducteurs et d’une fiche à trois broches qui s’insère dans une prise de courant avec mise à la terre. Le conducteur vert (ou vert et jaune) du cordon est le fil de Cache de la boîte terre. Ne jamais raccorder le fil vert (ou vert et jaune) à une prise sous de prises a

Summary of the content on the page No. 17

Français AVERTISSEMENT: Éviter tout risque de décharge électrique. Ne jamais utiliser le compresseur avec un cordon électrique ou un cordon de rallonge endommagé ou dénudé. Inspecter régulièrement les cordons électriques. Ne jamais utiliser dans l’eau ou à proximité de l’eau, ou dans un environnement susceptible de provoquer des décharges électriques. CONSERVER CES INSTRUCTIONS ET LES METTRE À LA DISPOSITION DES PERSONNES QUI VONT UTILISER L’APPAREIL! — 17 —

Summary of the content on the page No. 18

Français UTILISATION ET ENTRETIEN REMARQUE : Les informations que vous trouverez dans ce manuel sont conçues pour vous aider à utiliser et à entretenir ce compresseur en toute sécurité. Certaines illustrations de ce manuel peuvent montrer des détails qui diffèrent de ceux de votre compresseur. NOM DES PIÈCES Filtre d’admission Sélecteur de l’interrupteur barométrique Sélecteur de l’interrupteur barométrique Filtre d’admission Culasse Bouton du réducteur de pression Bouton du réducteur de pressio

Summary of the content on the page No. 19

Français SPÉCIFICATIONS Modèle EC6B EC6C EC12 EC16 Moteur Moteur à induction monophasé Alimentation Monophasée, 115 V – 60 Hz 1 CV 1 CV 2 CV 2 1/2 CV Entrée (0,75 KW) (0,75 KW) (1,49 KW) (1,87 KW) Courant 7,8A 10,05A 13,5A 13,5A 3,3 gal. 3,3 gal. 4 gal. 5 gal. Contenance du réservoir (12,5 R) (12,5 R) (15,1 R) (18,9 R) 125 PSI 125 PSI 125 PSI 145 PSI Pression maximale (8,6 bars) (8,6 bars) (8,6 bars) (10,0 bars) à 40 PSI 3,2 CFM 3,0 CFM 4,2 CFM 4,9 CFM (2,8 bar) (91 R/min) (85 R/min) (119 R/min)

Summary of the content on the page No. 20

Français Jauge de niveau d’huile AVANT L’UTILISATION 1. Source d’alimentation Vérifier que la source d’alimentation que l’on prévoit d’utiliser est conforme aux spécifications mentionnées sur la plaque signalétique de l’appareil. 2. Interrupteur d’alimentation Vérifier que le sélecteur de l’interrupteur MAX. barométrique se trouve sur la position «OFF» . Si l’on MIN. branche la ficha dans la prise alors que le sélecteur de EC6B l’interrupteur barométrique se trouve sur «AUTO», le (EC16) () EC12


Alternative user manuals
# User manual Category Download
1 Hitachi EC 189 User manual Air Compressor 6
2 Hitachi EC 129 User manual Air Compressor 3
3 Hitachi EC 12 User manual Air Compressor 110
4 Hitachi EC 25E / AC1-PH55-08H TECHNICAL User manual Air Compressor 5
5 Hitachi EC 16 User manual Air Compressor 1
6 Hitachi EC 510 User manual Air Compressor 52
7 Hitachi EC 79 User manual Air Compressor 10
8 Hitachi EC119 OM User manual Air Compressor 1
9 Hitachi EC 6B User manual Air Compressor 10
10 Hitachi Air Compressor EC 129 User manual Air Compressor 0
11 Directed Electronics 350HV User manual Air Compressor 5
12 12Volt 12V6CF User manual Air Compressor 2
13 Alesis 3630 User manual Air Compressor 260
14 AllTrade 835533 User manual Air Compressor 1
15 AllTrade 835579 User manual Air Compressor 3