Emerson 20/20 user manual

User manual for the device Emerson 20/20

Device: Emerson 20/20
Category: Air Compressor
Manufacturer: Emerson
Size: 6.89 MB
Added : 9/26/2013
Number of pages: 120
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson 20/20. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson 20/20.

For your convenience

If looking through the Emerson 20/20 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson 20/20 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson 20/20 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson 20/20 User manual - Online PDF
Advertisement
« Page 1 of 120 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson 20/20 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson 20/20. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Vission 20/20 micro-controller
Operation and service manual

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Table of Contents Section Title Section Number How To Use This Manual ....................................................................................................................TOC-8 Section 1 • Operational Flow Charts Requirements to Start Compressor ...................................................................................................1-1 Critical Compressor Run Logic at Compressor Start ...........................................................................1-1 Compres

Summary of the content on the page No. 4

Table of Contents Section Title Section Number Section 4 • Main Screen Overview ..........................................................................................................................................4-1 Figure 4-1. Digital I/O Board Layout...................................................................................................4-1 Top Status Bar ............................................................................................................................

Summary of the content on the page No. 5

Table of Contents Section Title Section Number Section 10 • Compressor Sequencing Overview ..........................................................................................................................................10-1 Pressure Control Setpoints ................................................................................................................10-1 Figure 10-1. Compressor Sequencing Screen ................................................................................

Summary of the content on the page No. 6

Table of Contents Section Title Section Number Section 16 • Event List Overview ..........................................................................................................................................16-1 Event list Columns .............................................................................................................................16-1 Figure 16-1. Event List Screen .................................................................................................

Summary of the content on the page No. 7

Table of Contents Section Title Section Number Section 20 • Data Backup Overview ..........................................................................................................................................20-1 Save / Load ........................................................................................................................................20-1 Figure 20-1. Data Backup Screen - Save/Load ...............................................................................

Summary of the content on the page No. 8

List of Tables and Figures Table/Figure Page Number Table 3-1. Digital I/O .........................................................................................................................3-3 Table 3-2. Analog Inputs....................................................................................................................3-5 Table 3-3. Analog Outputs.................................................................................................................3-7 Table 3-4. An

Summary of the content on the page No. 9

List of Tables and Figures Table/Figure Page Number Figure 19-4. Configuration Screen - Page 4 ........................................................................................19-7 Figure 19-5. Configuration Screen - Page 5 ........................................................................................19-8 Figure 19-6. Configuration Screen - Page 6 ........................................................................................19-9 Figure 20-1. Data Backup Screen - Save/L

Summary of the content on the page No. 10

How to Use This Manual This manual contains instructions for the Vission 20/20 CAUTION - Caution statements are shown when there Operation & Service Manual. It has been divided into 25 are potentially hazardous situations, if not avoided, will sections. result in damage to equipment. Section 1: Operational Flow Charts NOTE - Notes are shown when there are addtional infor- mation pertaining to the instructions explained. Section 2: Installation Recommendations Section 3: Hardware Architecture N

Summary of the content on the page No. 11

Section 1 • Operational Flow Charts Requirements to Start Compressor Volume and Oil Separator Temp Filter Diff Press < Capacity slides are >Oil Sep Start Trip Start Filter Diff Trip less than 5% Setpt Setpt Oil Pump On: Prelub Oil Press is > Prelub Oil Press Reset Setpt for “Min Compressor Prelub Timer” Start Compressor setting (typically 5 seconds) Critical Compressor Run Logic at Compressor Start Start Compressor Is Is “Oil Press Run Oil Press> Run Oil Press> Bypass at Comp Run Oil Press

Summary of the content on the page No. 12

Section 1 • Operational Flow Charts Suction Pressure Override Load Limit During Temperature Control Is Suction Press < Capacity Increase Suct Press Cap Yes Disabled Dec OFF Setpt? No Is Suction Press < Decrease compressor capacity until Suction Yes Suct Press Cap Press > Suction Press Cap Decrease ON setpoint. Dec ON Setpt? Normal Loading and No Unloading Figure 1-1. Operational Flow Charts (2 of 2) Vission 20/20 • Operation and Service Manual •Vilter/Emerson • 35391SC 1.8.5153 1 – 2

Summary of the content on the page No. 13

Section 2 • Installation Recommendations Electro-Magnetic Interference (EMI). The Vilter Proper Wiring Sizing Vission 20/20 should be isolated with its own con- • Always size wire gauges as specifi ed by the National trol transformer for the most reliable operation, see Electrical Code (NEC) for electronic control devices. Figure 2-1. Vission 20/20 with Individual Transformer. • For improved noise immunity, install one size larger • Connecting the Vilter Vission 20/20 to breaker panels wire

Summary of the content on the page No. 14

Section 2 • Installation Recommendations Each voltage level must be run in separate conduit: Grounding • Continuous grounds must be run from the util- • 460 VAC ity ground to the Vission 20/20, see Figure 2-3. • 230 VAC Grounding. • 120 VAC • Grounds must be copper or aluminum wire. • 24 VAC • Never use conduit grounds. DC signals Mixing Voltages • If your installation site has wire-ways or conduit trays, • Separate different voltages from each other and dividers must be installed between the

Summary of the content on the page No. 15

Section 2 • Installation Recommendations Wiring Methods • Each Vission 20/20 panel should have its own indi- vidual control transformer, see Figure 2-5. Correct Transformer Wiring Method and Figure 2-6. Incorrect Transformer Wiring Method. Figure 2-5. Correct Transformer Wiring Method Figure 2-6. Incorrect Transformer Wiring Method Vission 20/20 • Operation and Service Manual •Vilter/Emerson • 35391SC 1.8.5153 2 – 3

Summary of the content on the page No. 16

Section 2 • Installation Recommendations Best Practices • Do: • Keep AC wires away from circuit boards. • Always run conduit into the bottom or sides of an enclosure. • If the conduit must be placed in the top of an enclosure, use a water-tight conduit fi tting to keep water from entering the enclosure. • The Vission 20/20 is supplied with pre- punched conduit holes. Use them! • Don’t: • Don’t run wires through the Vission 20/20 enclosure that are not related to the compres- sor control. • Do

Summary of the content on the page No. 17

Section 3 • Hardware Architecture Overview The Vission 20/20 control panel utilizes X-86 PC technol- ogy with a Linux operating system. For hardware archi- tecture, see Figure 3-1 Hardware Architecture Overview. The Vission 20/20 has the following attributes: • Low power, Industrial rated X-86 CPU. • 15” XGA, high resolution LCD display. (Outdoor view- able LCD optional). • 8-wire touch screen operator interface. • Flexible and expandable I/O. • NEMA-4 enclosure (NEMA-4X optional). • Industrial

Summary of the content on the page No. 18

Section 3 • Hardware Architecture Trip Output: Digital Input/Output (I/O) Refer to Table 2-1. Digital I/O. • This output is energized when the system has no Trips. If a trip is issued, the output de-energizes and stays de-energized until the trip condition is cleared. Compressor Start Output: Slide Valve Setpoint #1 Output (Economizer): • When the Vission 20/20 signals the compressor to • Normally used for an economizer solenoid, but could start, this output is energized. When the Vission b

Summary of the content on the page No. 19

Section 3 • Hardware Architecture Table 3-1. Digital I/O (1 of 2) Board I/O # Description Type 1 1 Compressor Start OUTPUT 1 2 Oil Pump Start OUTPUT 1 3 Capacity Increase OUTPUT 1 4 Capacity Decrease OUTPUT 1 5 Volume Increase OUTPUT 1 6 Volume Decrease OUTPUT 1 7 Oil Separator Heater OUTPUT 2 8 Trip indicator (ON=Normal) OUTPUT 2 9 Slide Valve Set point #1 (Economizer) OUTPUT 2 10 Slide Valve Set point #2 (Hot Gas) OUTPUT 2 11 Alarm OUTPUT 212 Unused OUTPUT 2 13 Liquid Injection #1 OUTPUT 2 14

Summary of the content on the page No. 20

Section 3 • Hardware Architecture Condenser Step #3 Output: High Level Shutdown Input: • This output is enabled when condenser control op- • This input must be energized in order for the com- tion is selected. A condenser fan or pump will be pressor to operate. If de-energized, the compressor turned on or off by this output. will shut down and issue a high level trip. Condenser Step #4 Output: Oil Level Float Switch #1 Input: • This output is enabled when condenser control op- • Used for Cool


Alternative user manuals
# User manual Category Download
1 Emerson COPELAND SCROLL SZV22 User manual Air Compressor 3
2 Emerson 450XL User manual Air Compressor 3
3 Emerson SZO44 User manual Air Compressor 0
4 Emerson AE4-1395 User manual Air Compressor 1
5 Emerson SZV32 User manual Air Compressor 1
6 Emerson SZO56 User manual Air Compressor 0
7 Emerson VSM User manual Air Compressor 0
8 Emerson VISSION 20/20 User manual Air Compressor 11
9 Emerson 400 VMC User manual Air Compressor 37
10 Emerson SZV44 User manual Air Compressor 0
11 Emerson VSG User manual Air Compressor 3
12 Emerson VSS User manual Air Compressor 4
13 Emerson VSR User manual Air Compressor 4
14 Emerson SCROLL SZO44 User manual Air Compressor 0
15 Emerson VSSG User manual Air Compressor 1
16 Directed Electronics 350HV User manual Air Compressor 5
17 12Volt 12V6CF User manual Air Compressor 2
18 Alesis 3630 User manual Air Compressor 260
19 AllTrade 835533 User manual Air Compressor 1
20 AllTrade 835579 User manual Air Compressor 3