Bryant 580J*08--14D user manual

User manual for the device Bryant 580J*08--14D

Device: Bryant 580J*08--14D
Category: Air Compressor
Manufacturer: Bryant
Size: 5.81 MB
Added : 6/15/2014
Number of pages: 85
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bryant 580J*08--14D. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bryant 580J*08--14D.

For your convenience

If looking through the Bryant 580J*08--14D user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bryant 580J*08--14D on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bryant 580J*08--14D to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bryant 580J*08--14D User manual - Online PDF
Advertisement
« Page 1 of 85 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bryant 580J*08--14D but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bryant 580J*08--14D. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

580J*08--14D,F(2--COMPRESSOR)
NOMINAL7.5to12.5TONS
WITHPURONR(R--410A)REFRIGERANT
ServiceandMaintenanceInstructions
TABLEOFCONTENTS SAFETYCONSIDERATIONS
SAFETY CONSIDERATIONS .................... 1
Installation and servicing of air-conditioning equipment
can be hazardous due to system pressure and electrical
UNIT ARRANGEMENT AND ACCESS ........... 2
components. Only trained and qualified service personnel
SUPPLY FAN (BLOWER) SECTION .............. 4
should install, repair, or service air-conditi

Summary of the content on the page No. 2

! ! WARNING WARNING FIRE, EXPLOSIONHAZARD FIRE, EXPLOSIONHAZARD Failure to follow this warning could result in personal Failure to follow this warning could result in injuryordeath. personal injury, deathand/orpropertydamage. Disconnect gas piping from unit when pressure testing Refer to the User’s Information Manual provided at pressure greater than 0.5 psig. Pressures greater withthisunitformoredetails. than 0.5 psig will cause gas valve damage resulting in Do not store or use gasoline or othe

Summary of the content on the page No. 3

Heating S Heatexchangerfluepassagewayscleanliness S Gasburnercondition S Gasmanifoldpressure S Heatingtemperature rise EconomizerorOutsideAirDamper S Inlet filterscondition S Checkdampertravel(economizer) BLOWER ACCESS S Checkgearanddampersfordebrisanddirt PANEL AirFiltersandScreens CONTROL BOX COMPRESSORS Each unit is equipped with return air filters. If the unithas an economizer, it will also have an outside air screen. If a C09239 manual outside air damper is added, an inlet air screen Fig. 2

Summary of the content on the page No. 4

SUPPLYFAN(BLOWER)SECTION 22 3/8 (569 mm) ! WARNING ELECTRICALSHOCKHAZARD Failure to follow this warning could cause personal injuryordeath. DIVIDER Before performing service or maintenance operations OUTSIDE on the fan system, shut offall unit power andtag--out AIR the unit disconnect switch. Do not reach into the fan HOOD sectionwithpowerstillappliedtounit. CLEANABLE ALUMINUM FILTER SupplyFan(Belt--Drive) FILTER The supply fan system consists of a forward--curved BAROMETRIC centrifugal blower w

Summary of the content on the page No. 5

To replace the belt: To align fan and motor pulleys: 1. Use a belt with same section type or similar size. Do 1. Loosen fan pulley setscrews. not substitute a “FHP” type belt. When installing the 2. Slide fan pulley along fan shaft. Make angular align- new belt, do not use a tool (screwdriveror pry--bar)to ment by loosening motor from mounting. force the belt over the pulley flanges, this will stress 3. Tighten fan pulley setscrews and motor mounting the belt and cause a reduction in belt life.

Summary of the content on the page No. 6

TUBES ChangingtheFanWheelSpeedbyChangingPulleys The horsepower rating of the belt is primarily dictated by FINS the pitch diameter of the smaller pulley in the drive system (typically the motor pulley in these units). Do not install a replacement motor pulley with a smaller pitch diameter than provided on the original factory pulley. Change fan wheel speed by changing the fan pulley (larger pitch diameter to reduce wheel speed, smaller pitch diameter to increase wheel speed) or select a new syst

Summary of the content on the page No. 7

RoutineCleaningofNOVATIONCondenserCoil Totaline Environmentally Sound Coil Cleaner Application Surfaces Equipment S 2-1/2gallongardensprayer To clean the NOVATION condenser coil, chemicals are NOT to be used; only water is approved as the cleaning S waterrinsewithlowvelocityspraynozzle solution. Only clean potable water is authorized for cleaning NOVATION condensers. Carefully remove any ! CAUTION foreign objects or debris attached to the coil face or trapped within the mounting frame and bracke

Summary of the content on the page No. 8

9. Finned surfaces should remain wet with cleaning Because Puron (R--410A) refrigerant is a blend, it is solution for 10 minutes. strongly recommended that refrigerant always be removed from the cylinder as a liquid. Admit liquid refrigerant into 10. Ensure surfaces are not allowed to dry before rinsing. the system in the discharge line. If adding refrigerant into Reapply cleaner as needed to ensure 10--minute satur- the suction line, use a commercial metering/expansion ation is achieved. device

Summary of the content on the page No. 9

SEAT CORE (Part No. EC39EZ067) 1/2-20 UNF RH 0.596 o 45 o 30 WASHER DEPRESSOR PER ARI 720 O-RING +.01/-.035 1/2" HEX .47 FROM FACE OF BODY 5/8” HEX 7/16-20 UNF RH This surface provides a metal to metal seal when torqued into the seat. Appropriate handling is required to not scratch or dent the surface. C08453 Fig. 9 -- CoreMax AccessPort Assembly EXAMPLE: Model 580J*14D Circuit 1: Outdoor Temperature.................. 85_F(29_C) Suction Pressure................. 125 psig (860 kPa) Sucti

Summary of the content on the page No. 10

COOLINGCHARGINGCHARTS C09221 Fig. 10 -- Cooling Charging Charts (08D,F -- Both Circuits) 10 580J

Summary of the content on the page No. 11

COOLINGCHARGINGCHARTS C09222 Fig. 11 -- Cooling Charging Charts (12D,F -- Both Circuits) 11 580J

Summary of the content on the page No. 12

COOLINGCHARGINGCHARTS 12.5 TON CIRCUIT 1 C09240 Fig. 12 -- Cooling Charging Charts (14D,F -- Circuit 1) 12 580J

Summary of the content on the page No. 13

COOLINGCHARGINGCHARTS 12.5 TON CIRCUIT 2 C09241 Fig. 13 -- Cooling Charging Charts (14D,F -- Circuit 2) 13 580J

Summary of the content on the page No. 14

Table1–CoolingServiceAnalysis PROBLEM CAUSE REMEDY Power failure. Callpowercompany. Fuseblownorcircuitbreakertripped. Replacefuseorresetcircuitbreaker. Defectivethermostat,contactor,transformer, Replacecomponent. CompressorandCondenser orcontrolrelay. Fan WillNotStart. Insufficientlinevoltage. Determinecauseand correct. Incorrectorfaulty wiring. Checkwiring diagramand rewirecorrectly. Thermostatsetting toohigh. Lowerthermostatsetting belowroomtemperature. Faultywiring orlooseconnectionsin Checkw

Summary of the content on the page No. 15

The suction and discharge pressure levels should now Compressors move to their normal start--up levels. Lubrication NOTE: When the compressor is rotating in the wrong Compressors are charged with the correct amount of oil at direction, the unit makes an elevated level of noise and the factory. does not provide cooling. FilterDrier ! CAUTION Replace whenever refrigerant system is exposed to atmosphere. Only use factory specified liquid--line filter UNIT DAMAGE HAZARD driers with working pressures

Summary of the content on the page No. 16

CONVENIENCEOUTLETS COVER - WHILE-IN-USE WEATHERPROOF ! WARNING ELECTRICALOPERATIONHAZARD Failure to follow this warning could result in personal injuryordeath. Units with convenience outlet circuits may use multiple disconnects. Check convenience outlet for power status before opening unit for service. Locate its disconnect switch, if appropriate, and open it. Tag--outthisswitch, ifnecessary. Two types of convenience outlets are offered on 580J models: Non--powered and unit--powered. Both types

Summary of the content on the page No. 17

UsingUnit--MountedConvenienceOutlets Units with unit--mounted convenience outlet circuits will often require that two disconnects be opened to de--energize all power to the unit. Treat all units as electrically energized until the convenience outlet power isalsocheckedand de--energizationis confirmed. Observe National Electrical Code Article 210, Branch Circuits, for use of convenience outlets. SMOKEDETECTORS Smoke detectors are available as factory--installed options on 580J models. Smoke detec

Summary of the content on the page No. 18

Duct smoke sensor Duct smoke sensor controller Exhaust tube Conduit nuts Exhaust gasket (supplied by installer) Sensor housing and electronics See Conduit support plate Detail A Terminal block cover Intake Controller housing Cover gasket gasket and electronics (ordering option) Cover gasket (ordering option) Controller cover Conduit couplings (supplied by installer) TSD-CO2 (ordering option) Sensor cover Plug Fastener (2X) Sampling tube (ordered separately) Coupling Detail A Trouble Alarm Power

Summary of the content on the page No. 19

ReturnAirWithoutEconomizer CompletingInstallationofReturnAirSmoke Sensor The sampling tube is located across the return air opening on the unit basepan. (See Fig. 22.) The holes in the 1. Unscrew the two screws holding the Return Air sampling tube face downward, into the return air stream. Sensor detector plate. (See Fig. 24.) Save the screws. The samplingtube isconnected via tubing tothe returnair 2. Remove the Return Air Sensor and its detector plate. sensor that is mounted on a bracket high o

Summary of the content on the page No. 20

B D C F E A C08246 Fig. 26 -- Typical Smoke Detector System Wiring HighlightB Additional Application Data — Refer to Catalog No. HKRNKA--1XA for discussions on additional control Smoke detector NC contact set will open on smoke alarm features of these smoke detectors including multiple unit condition, de--energizing the ORN conductor. coordination. (See Fig. 26.) HighlightC SensorandControllerTests 24--v power signal via ORN lead is removed at Smoke SensorAlarmTest Detector input on LCTB; all un


Alternative user manuals
# User manual Category Download
1 Bryant 559E User manual Air Compressor 0
2 Bryant F User manual Air Compressor 0
3 Directed Electronics 350HV User manual Air Compressor 5
4 12Volt 12V6CF User manual Air Compressor 2
5 Alesis 3630 User manual Air Compressor 260
6 AllTrade 835533 User manual Air Compressor 1
7 AllTrade 835579 User manual Air Compressor 3
8 AllTrade 830211 User manual Air Compressor 4
9 AllTrade 835446 User manual Air Compressor 1
10 AllTrade 835534 User manual Air Compressor 0
11 AllTrade 835408 User manual Air Compressor 1
12 Acer AX3910-U2032 User manual Air Compressor 29
13 AllTrade Trades Pro 835081 User manual Air Compressor 18
14 American Eagle Outfitters American Eagle Compressor User manual Air Compressor 7
15 AllTrade #540025 User manual Air Compressor 2