Summary of the content on the page No. 1
CLOTHES DRYER
Technical Information
IMPORTANT SAFETY NOTICE – “For Technicians only” This service data sheet is intended for
use by persons having electrical, electronic, and mechanical experience and knowledge at a level
generally considered acceptable in the appliance repair trade. Any attempt to repair a major
appliance may result in personal injury and property damage. The manufacturer or seller cannot
be responsible, nor assume any liability for injury or damage of any kind arising from
Summary of the content on the page No. 2
ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. ERROR ITEMS AND DIAGNOSTIC CODES An occurrence of an Error will make a sound of error melody for 5sec and continuously show one of the Error Displays from the following errors. Error Display Trigger Action Taken Check for: - Clogged lint screen. The Thermistor resistance is very low or tE high. - Restricted vent system. - Che
Summary of the content on the page No. 3
ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. TEST MODE Data Display Mode How to Enter: - In normal mode, press Drylevel Time Temp Time in less than 2 seconds to enter the display mode. - To change the mode, use the cycle selector dial. Definition of Data Display Mode: - Display Mode 1 : Main micom version - Display Mode 2 : display micom version - Display Mode 3 :
Summary of the content on the page No. 4
ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. TROUBLE DIAGNOSIS - As the micom dry machine is configured of the complicate structure, there might be the service call. Below information is prepared for exact trouble diagnosis and suitable repair guide. Caution for the Repair and Replacement Please follow below instruction for the trouble diagnosis and parts replacement.
Summary of the content on the page No. 5
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. No Problem What To Do • All wires are hooked up to their corresponding terminals. • Dryer is plugged in. • Blown fuse or circuit breaker. • Door switch functional...door closed. Check for error code 3 (See Table for codedefinition). 1 Will Not Start or Run • Start/Pause rotary selector dial functional. • Control Board operational. • Be
Summary of the content on the page No. 6
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. No Problem What To Do If the igniter does not heat up, remove power and using an ohmmeter, check the following: • Open flame sensor The igniter does not • Open igniter 8 glow • Shorted booster coil • Open wiring • Bad motor switch ( Neutral supply) • No power from control ( L1 supply) If the igniter heats up but the main burner flame i
Summary of the content on the page No. 7
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. COMPONENT TESTING PROCEDURES Belt Cut-off S/W Component Electrical Testing (with ohmmeter) - Lever open: Resistance value < 1Ω Thermistor resistance 10K Ω @ 25°C 77°F - Lever push: Resistance value : ∞ Ω Thermostat 1 resistance < 1Ω Lamp resistance : ∞ Ω, (-) : BLU, (+) : WHT Thermostat 3 resistance < 1Ω - If resistance is
Summary of the content on the page No. 8
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. THERMISTOR 238.23Ω @ 25 °C 77 GAS MODEL Radiant Sensor(10RS) Gas Valve(25M01A) Resistance value < 1 Ω Valve 1-2 : Resistance value about 1365 Ω If resistance is infinite, replace Radiant sensor Valve 1-3 : Resistance value about 560 Ω Valve 4-5 : Resistance value about 1325 Ω If resistance is infinity, replace Valve Igniter(101D) Resis
Summary of the content on the page No. 9
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. Sensor Bars & temperature sensor check Sensor Bars - Disconnect harness and test Pink wire Pin 4 to Orange wire Pin 5. Approx ∞ Ω without laundry Approx 190 Ω ± 10 % with wet clothes Cycling Thermistor 1 - Disconnect harness and test Blue wire Pin 3 to Red wire Pin 6. Approx 10 KΩ at 25 °C / 77 °F Vent Thermistor 2 (Vent sensor model
Summary of the content on the page No. 10
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. 3-WIRE system connections A. External ground connector B. Neutral grounding wire (green/yellow) C. Center silver-colored terminal block screw D. Neutral wire (white or center wire) E. ¾” (1.9 cm) UL-listed strain relief 1. Loosen or remove the center terminal block screw. 2. Connect the neutral wire (white or center wire) of the power
Summary of the content on the page No. 11
WIRING DIAGRAM WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. WIRING DIAGRAM DV45H6300E*, DV42H5600E* DV45H6300G*, DV42H5600G* 11 Technical_information-03382A_EN_131209.indd 11 2013-12-09 �� 5:37:45
Summary of the content on the page No. 12
WIRING DIAGRAM WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. WIRING DIAGRAM DV42H5400*, DV42H5200*, DV42H5000* 12 Technical_information-03382A_EN_131209.indd 12 2013-12-09 �� 5:37:45
Summary of the content on the page No. 13
SÈCHE-LINGE Informations techniques CONSIGNE DE SÉCURITÉ IMPORTANTE : réservée aux techniciens Cette fiche de maintenance est destinée aux réparateurs disposant d'un niveau d'expérience et de connaissances suffisants en matière d'électricité, d'électronique et de mécanique. Toute opération de réparation d'un gros appareil électro-ménager est susceptible d'entraîner des blessures ou des dégâts matériels. Le fabricant ou le vendeur ne peut pas être tenu responsable en cas de blessure ou de dég
Summary of the content on the page No. 14
ALIGNEMENTS ET RÉGLAGES AVERTISSEMENT Afin d'éviter tout risque d'électrocution légère ou mortelle, débranchez le sèche-linge avant de le réparer, sauf si le test nécessite sa mise sous tension. CODES D'ERREUR ET DIAGNOTICS Lorsqu'une erreur se produit, un signal sonore retentit pendant 5 secondes et l'un des messages d'erreur suivants s'affiche en continu. Affichage de Problème Vérification l'erreur Diagnostic possible : - Filtre à peluches bouché. La résistance de la thermistance est très
Summary of the content on the page No. 15
ALIGNEMENTS ET RÉGLAGES AVERTISSEMENT Afin d'éviter tout risque d'électrocution légère ou mortelle, débranchez le sèche-linge avant de le réparer, sauf si le test nécessite sa mise sous tension. MODE DE TEST Mode d'affichage des données Pour sélectionner ce mode : - En mode normal, appuyez sur Drylevel (Niveau de séchage) Time (Temps) Temp (Température) Time (Temps) en moins de 2 secondes pour passer en mode d'affichage. - Pour changer le mode, utilisez la molette de sélection de progra
Summary of the content on the page No. 16
ALIGNEMENTS ET RÉGLAGES AVERTISSEMENT Afin d'éviter tout risque d'électrocution légère ou mortelle, débranchez le sèche-linge avant de le réparer, sauf si le test nécessite sa mise sous tension. DIAGNOSTIC DES PROBLÈMES - Le micom du sèche-linge est configuré pour une structure complexe, c'est pourquoi il est conseillé de contacter le service après-vente. Les informations suivantes répondent à un diagnostic précis et constituent un guide de réparation adapté. Consignes à respecter pendant
Summary of the content on the page No. 17
DÉPANNAGE AVERTISSEMENT Afin d'éviter tout risque d'électrocution légère ou mortelle, débranchez le sèche-linge avant de le réparer, sauf si le test nécessite sa mise sous tension. N° Problème Procédure à suivre • Tous les câbles sont branchés sur leurs bornes correspondantes. • Le sèche-linge est branché. • Le fusible est grillé ou le disjoncteur est déclenché. • Interrupteur du hublot fonctionnel...hublot fermé. Vérifiez le code d'erreur 3 (reportez-vous au tableau pour la définition des cod
Summary of the content on the page No. 18
DÉPANNAGE AVERTISSEMENT Afin d'éviter tout risque d'électrocution légère ou mortelle, débranchez le sèche-linge avant de le réparer, sauf si le test nécessite sa mise sous tension. N° Problème Procédure à suivre Si l'allumeur ne chauffe pas, coupez l'alimentation et à l'aide d'un ohmmètre, vérifiez les points suivants : • Détecteur de flamme en circuit ouvert • Allumeur en circuit ouvert L'allumeur ne s'allume 8 pas. • Survolteur court-circuité • Câblage en circuit ouvert • Commutateur de mot
Summary of the content on the page No. 19
DÉPANNAGE AVERTISSEMENT Afin d'éviter tout risque d'électrocution légère ou mortelle, débranchez le sèche-linge avant de le réparer, sauf si le test nécessite sa mise sous tension. PROCÉDURES DE TEST DES COMPOSANTS Commutateur d'arrêt de la courroie Test des composants électriques (avec ohmmètre) - Manette ouverte : valeur ohmique < 1 Ω Résistance de la thermistance 10 KΩ @ 25 °C (77 °F) - Manette actionnée : valeur ohmique : ∞ Ω Résistance du thermostat 1 < 1 Ω Résistance de la lampe
Summary of the content on the page No. 20
DÉPANNAGE AVERTISSEMENT Afin d'éviter tout risque d'électrocution légère ou mortelle, débranchez le sèche-linge avant de le réparer, sauf si le test nécessite sa mise sous tension. THERMISTANCE 238,23 Ω à 25 °C 77 °F MODÈLE À GAZ Capteur radiant (10RS) Soupape à gaz (25M01A) Valeur ohmique < 1 Ω Soupape 1-2 : Valeur ohmique 1365 Ω environ Si la résistance est infinie, remplacez le capteur Soupape 1-3 : Valeur ohmique 560 Ω environ radiant Soupape 4-5 : Valeur ohmique 1325 Ω environ Si la résis