IPSO TMB1268C user manual

User manual for the device IPSO TMB1268C

Device: IPSO TMB1268C
Category: Clothes Dryer
Manufacturer: IPSO
Size: 0.53 MB
Added : 8/9/2014
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for IPSO TMB1268C. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with IPSO TMB1268C.

For your convenience

If looking through the IPSO TMB1268C user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual IPSO TMB1268C on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual IPSO TMB1268C to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
IPSO TMB1268C User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual IPSO TMB1268C but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to IPSO TMB1268C. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

On-Premise
Laundry
Planning
Handbook
TMB1268C
TMB1268C
120 and 170 Pound Tumblers
Starting Serial No. 0907003062
Refer to Installation manual for full instructions.
3-09-71R5
August 2011

Summary of the content on the page No. 2

Tumblers – 120 and 170 ..................................................................... 2 Table of Introduction...................................................................................... 2 Model Identification .................................................................. 2 Contents Specifications and Dimensions ........................................................ 4 120 Pound Tumbler Dimensions and Exhaust Outlet Locations 5 170 Pound Tumbler Dimensions and Exhaust Outle

Summary of the content on the page No. 3

Tumblers – 120 and 170 Introduction TMB1268C TMB1268C Model Identification Gas Steam/Thermal Oil IPD120G2-IT120L IPD120G2-IT120N IPD120S2-IT120S IPD120S2-IT120T 120 Pound IPD170G2-IT170L IPD170G2-IT170N IPD170S2-IT170S IPD170S2-IT170T 170 Pound Includes models with the following control suffixes: RD – reversing DMP OPL RE – reversing LED OPL RQ – reversing dual digital timer 3-09-71 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 2

Summary of the content on the page No. 4

Tumblers – 120 and 170 1 1 TMB2288N 120 POUND TUMBLER 170 POUND TUMBLER TMB2288N 1 Serial Plate Conversion Table Multiply By To Obtain Multiply By To Obtain Btu 0.252 kCal Pounds/sq. inch 0.06895 Bars Btu 1055 Joules Pounds/sq. inch 0.070 kg/sq. cm Inch 25.4 Millimeters Pounds (lbs.) 0.454 Kilograms Inches W.C. 0.036 Pounds/sq. inch Boiler Horsepower 33,479 Btu/hr. Inches W.C. 0.249 kPa Boiler Horsepower 34.5 lbs. steam/hr. 2 lb./inch (psi) 6.895 kPa CFM 0.471 liters/second 3 ft. 28.32 Liters kW

Summary of the content on the page No. 5

Tumblers – 120 and 170 Specifications and Dimensions Specifications 120 Pound 170 Pound 66 dBA 66 dBA Noise level measured during operation at operator position of 3.3 feet (1 meter) in front of machine and 5.2 feet (1.6 meters) from floor. 44 x 41 50.75 x 42.5 Cylinder Size: (1118 x 1041) (1289 x 1080) Inches (mm) 120 170 Cylinder Capacity dry weight: (54.4) (77.1) Pounds (kg) 0.75 0.75 Cylinder Motor Horsepower 13 Fan Motor Horsepower 10 12 Air Outlet Diameter: (254) (300) Inches (mm) 0.3 0

Summary of the content on the page No. 6

Tumblers – 120 and 170 120 Pound Tumbler Dimensions and Exhaust Outlet Locations TOP VIEW OF EXHAUST DUCT W X V H I U B A Y Z C F D E G TMB2326N TMB2326N Cabinet Dimensions Models A B C D E F G H I 31.38 in. 32.5 in. 48.91 in. 49.91 in. 67.92 in. 45.38 in. 46.38 in. 85.7 in. 70 in. 120L/N (797 mm) (826 mm) (1242 mm) (1268 mm) (1725 mm) (1153 mm) (1178 mm) (2177 mm) (1778 mm) 31.38 in. 32.5 in. 48.91 in. 49.91 in. 67.92 in. 45.38 in. 46.38 in. 83.5 in. 70 in. 120S (797 mm) (826 mm) (1242 mm) (

Summary of the content on the page No. 7

Tumblers – 120 and 170 170 Pound Tumbler Dimensions and Exhaust Outlet Locations TOP VIEW OF EXHAUST DUCT X W Y H I B V A C F D E G TMB2327N TMB2327N Cabinet Dimensions Models A BCD E F G H I 33.86 in. 32.5 in. 50.75 in. 51.75 in. 68.85 in. 52.12 in. 53.12 in. 94 in. 75.12 in. 170L/N/S (860 mm) (826 mm) (1289 mm) (1314 mm) (1749 mm) (1324 mm) (1349 mm) (2388 mm) (1908mm) Refer to Position and Level the Tumbler to temporarily reduce the heights of these models. Exhaust Outlet Dimensions and Lo

Summary of the content on the page No. 8

Tumblers – 120 and 170 Electric and Gas Connection Locations for Gas Models A C A C D B B D 120L/N 170L/N TMB2255N Electrical Connection Gas Connection Models A B C D Diameter 18.34 in. 77.84 in. 12.5 in. 70.5 in. 3/4 in. NPT 120L/N (466 mm) (1977 mm) (318 mm) (1791 mm) 21 in. 81 in. 14.85 in. 77.4 in. 1 in. NPT 170L/N (533 mm) (2057 mm) (377 mm) (1966 mm) NOTE: These figures are approximate dimensions only. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 3-09-71 7

Summary of the content on the page No. 9

Tumblers – 120 and 170 Electric and Steam Connection Locations for Steam Models A1 A2 A1 A2 C C B2 B1 B2 B1 F E E F D D 120S 170S TMB2256N Steam Inlet Models Diameter A1 A2 F 3/4 in. NPT 35.875 in. 13.375 in. 82.75 in. 120S (911 mm) (340 mm) (2102 mm) 3/4 in. NPT 37.625 in. 15.25 in. 88 in. 170S (956 mm) (387 mm) (2235 mm) Steam Outlet Models Diameter B1 B2 D 3/4 in. NPT 34.625 in. 13.125 in. 68.5 in. 120S (879 mm) (333 mm) (1740 mm) 1 in. NPT 44.625 in. 8.75 in. 71.75 in. 170S (1133 mm) (222 m

Summary of the content on the page No. 10

Tumblers – 120 and 170 Installation Pre-Installation Inspection Upon delivery, visually inspect the crate, carton and parts for any visible shipping damage. If the crate, carton, or cover is damaged or signs of possible damage are evident, have the carrier note the condition on the shipping papers before the shipping receipt is signed, or advise the carrier of the condition as soon as it is discovered. Remove the crate and protective cover as soon as possible and check the items listed on

Summary of the content on the page No. 11

Tumblers – 120 and 170 Tumbler Enclosure WARNING To reduce the risk of severe injury, clearance of tumble dryer cabinet from combustible construction must conform to the minimum clearances. W056R1 3 1 2 4 5 6 TMB2020N 7 8 TMB2020N NOTE: Shaded areas indicate adjacent structure. 1 0.5 in. (13 mm) recommended between machines for removal or installation. 2 Allow 2-4 in. (51-102 mm) opening at top of machine to aid in removal or installation. A removable trim piece may be used to conceal the open

Summary of the content on the page No. 12

Tumblers – 120 and 170 Make-up air openings for a room containing Exhaust Requirements tumbler(s) and/or gas fired hot water heater or other gravity vented appliances must be increased WARNING sufficiently to prevent downdrafts in any of the vents when all tumblers are in operation. Do not locate A drying tumble dryer produces gravity vented appliances between tumbler(s) and combustible lint. To reduce the risk of fire, make-up air openings. If it is necessary to duct make- the tumble dr

Summary of the content on the page No. 13

Tumblers – 120 and 170 NOTE: Exhaust ducts must be constructed of sheet Duct Equivalent Length of metal or other noncombustible material. Such Diameter Rigid Straight Duct ducts must be equivalent in strength and corrosion resistance to ducts made of galvanized sheet steel 6 in. (152 mm) One 90° elbow = 7 ft. (2.1 m) not less than 0.0195 inches (0.495 mm) thick. Local 8 in. (203 mm) One 90° elbow = 9.3 ft. (2.83 m) codes may require additional thickness. 10 in. (254 mm) One 90° elbow = 11.

Summary of the content on the page No. 14

Tumblers – 120 and 170 3 4 2 1 5 TMB2103N TMB2103N 1 Removable strip of panel in framing wall to permit removal of tumbler from framing wall 2 Partition or bulkhead 3 Minimum distance between exhaust opening and roof, ground or other obstruction: 36 in. (914 mm) 4 2 in. (51 mm) minimum clearance on both sides of duct 5 Exhaust airflow – maximum length of duct: 14 ft. (4.3 m) Figure 2 NOTE: Do not install wire mesh or screen in NOTE: Inside of duct must be smooth. Do not use exhaust duct openin

Summary of the content on the page No. 15

Tumblers – 120 and 170 Manifold Venting NOTE: Never connect a tumbler duct at a 90° angle to the collector duct. Refer to Figure 3. Doing While it is preferable to exhaust tumblers individually so will cause excessive back pressure, resulting in to the outdoors, a main collector duct may be used if it poor performance. Never connect two tumbler is sized according to Figure 4 and Figure 5. This exhaust ducts directly across from each other at the illustration indicates minimum diameters,

Summary of the content on the page No. 16

Tumblers – 120 and 170 1 2 LK J I H G F E DC B A 3 ONE MANIFOLD ASSEMBLY TMB2019N 1 NOTE: Where the exhaust duct pierces a 2 Outlet Duct Diameter combustible wall or ceiling, the opening 3 45° Typical MUST be sized per local codes. Figure 4 120 Pound 170 Pound Duct Station 10 in. (254 mm) Duct 12 in. (305 mm) Duct 10 in. (254 mm) 12 in. (305 mm) A 15 in. (381 mm) 17 in. (432 mm) B 18 in. (457 mm) 21 in. (533 mm) C 21 in. (533 mm) 24 in. (610 mm) D 24 in. (610 mm) 27 in. (686 mm) E 26 in. (660

Summary of the content on the page No. 17

Tumblers – 120 and 170 1 2 L LK I I J K J CONTINUE CONTINUE TO A TO A 3 TWO MANIFOLD ASSEMBLIES TMB2018N TMB2018N 1 NOTE: Where the exhaust duct pierces a 2 Outlet Duct Diameter combustible wall or ceiling, the opening 3 45° Typical MUST be sized per local codes. Figure 5 120 Pound 170 Pound Duct Station 10 in. (254 mm) Duct 12 in. (305 mm) Duct 15 in. (381 mm) 17 in. (432 mm) A 21 in. (533 mm) 24 in. (610 mm) B 26 in. (660 mm) 30 in. (762 mm) C 30 in. (762 mm) 34 in. (864 mm) D 33 in. (838

Summary of the content on the page No. 18

Tumblers – 120 and 170 serial plate for most current specifications of Electrical Requirements product being installed. Refer to Table 5. NOTE: Use copper conductors only. NOTE: Minimum wire sizes are obtained from NOTE: 3 Phase Only– Each tumbler must be Canadian Electrical Code and are intended for use connected to its own individual branch circuit as a guideline only. Electrical connections should be breaker, not fuses, to avoid the possibility of “single made only by a qualified elect


Alternative user manuals
# User manual Category Download
1 IPSO DR50 User manual Clothes Dryer 415
2 ACS 882.00284.00 User manual Clothes Dryer 0
3 ACS 255 CMF (85 User manual Clothes Dryer 0
4 ACS 380 M3 /hr) User manual Clothes Dryer 0
5 Philips 1.07E+23 User manual Clothes Dryer 1
6 Philips 1.07E+31 User manual Clothes Dryer 3
7 Philips BABYSITTER SBC SC 368 User manual Clothes Dryer 17
8 Philips BABY MONITOR SBC SC368 User manual Clothes Dryer 3
9 Philips SBC SC369 User manual Clothes Dryer 0
10 Philips GL1015 User manual Clothes Dryer 0
11 Philips GL1045 User manual Clothes Dryer 0
12 ACS 255 User manual Clothes Dryer 0
13 Philips 190WV7 User manual Clothes Dryer 2
14 Philips Digital Audio Player SA 125 User manual Clothes Dryer 0
15 Philips SA 126 User manual Clothes Dryer 0