Summary of the content on the page No. 1
G
nstal ati
nst cti
If you have any questions, call 1-800-GECARES (US) or 1-800-361-3400 (Canada)
or Visit our Web site at: www. GEAppliances.com
WARN NG RIsK oF
BEFOREYOU BEGIN
Read these instructions completely and * To reduce the risk of severe i_j ury or death, follow all installation instructions.
carefully. * Clothes dryer installation must be performed by a qualified installer.
* Install the clothes dwer according to these instructions and in accordance with
"IMPORT. NT-Save hese
local c
Summary of the content on the page No. 2
Installation instructions Minimum Clearance Other Than Alcove or Closet Installation Minimum clearance m combustible surfhces and for air opening are: 0 in. clearance bofl_ sides and 1 in. rear. Consideration must be given m provide adequate clearance for proper operation and service. _q GAS REQUIREMENTS FT]PREPARING FOR iNSTALLATiON OF NEW DRYER WARNING * Installation IIIUSE conf()l'IIl tO local codes and ordinances, TIP: Install your dryer before installing your washer, or in their absence, th
Summary of the content on the page No. 3
Installation Instructions [] RECONNECTING GAS Listed connector ANSI Z21.24 / CSA 6.10 APPLYPiPECOMPOUND TOALL MALETHREADS. 118" NPT PIPE NEWMETAL PLUG FOR GAS FLEXIBLE GAS INLET PRESSURE LINECONNECTOR SHUT-OFF ADAPTER 3/8" NPT ELBOW PIPE SIZE ITEMSNOT SUPPLIED AT LEAST 1/2" Note: The connector and fittings are designed for use onty on the original insta[tation and are not to be reused for another appliance or at another location. Keep flare end of adaptor free of ]rease, oi[ and thread sealant.
Summary of the content on the page No. 4
Installation instructions F6-]EXHAUST iNFORMATiON [] ELECTRICAL CONNECTION iNFORMATiON _WARNING- IN CANADA AND IN THE UNITED STATES, THE REQUIRED EXHAUST DUCT DIAMETER WARNING- TO REDUCE THE RISK OF IS 4 IN (102ram). DO NOT USE DUCT LONGER FIRE, ELECTRICAL S HOCK, AND PERSONAL THAN SPECIFIED IN THE EXHAUST LENGTH TABLE. INJURY: l_ sing exhaust longer than specified length wilh * Increase the chying times and the energ F cost. * DO NOT USE AN EXTENSION CORD CRAM * Reduce the cho_er life. ADAPTER
Summary of the content on the page No. 5
Installation instructions [_ EXHAUST CONNECTION STANDARD REAR EXHAUST {Vented above floor level) _ WARNING - TO REDUCE THE RISK OF FIRE OR PERSONAL INJURY: ELBOW HIGHLY * This clothes dIyer must be exhausted to the outdoors. , Use only 4" rigid metal ducting for the home exhaust RECOMMENDED duct. e Use only 4" rigid metal or Ui,-listed flexible metal (semi-rigid or foil-type) duct to connect the d_yer to the home exhaust duct. It must be installed in accordance with the instructions found in "Co
Summary of the content on the page No. 6
Installation instructions CONNECTING THE DRYER TO HOUSE VENT RIGID METALTRANSITIONDUCT * For best d,Ting perff_rmance, a rigid metal transition duct is recommended. Do * Rigid metal transitions ducts reduce the risk of crush- ing and kinking. EXCESSIVE UL-LISTED FLEXIBLEMETAL(SEMI-RIGID) TRANSITION DUCT e If rigid metal duct cannot be used, then UiAisted flexible metal (semi-rigid) ducting can be used (Kit WX08X10077). * Never install flexible metal duct in walls, ceilings, floors or other enclo
Summary of the content on the page No. 7
Installation Instructions ADDING NEW DUCT I_ DRYER EXHAUST TO LEFT OR BOTTOM CABINET FIXING HOLE WARNING- BEFORE PERFORMING PORTION "A" THIS EXHAUST INSTALLATION, BE SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY. PROTECT YOUR HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE THE CABINET. BE SURE TO WEAR GLOVES LEFT SIDE EXHAUST Reconnect dm cut portion (A) of the duct to the blower REMOVE housing. Make sure that the shortened duct is aligned with SCREW the tab in the base. Use the sc
Summary of the content on the page No. 8
Installation Instructions [_ CHANGING DIRECTION OF ADDING ELBOW FOR EXHAUST DOOR OPENING THROUGH BOTTOM OF CABINET . Insert die elbow dn'ough the rear opening and connect it to tile dlyer internal duct. . Apply duct tape oil the joint between tile dryer internal duct and elbow, as shown on page 7. REMOVE 4 HOLE PLUGS AND PLACE THEMINTHEHOLES REMOVE 4 ONTHEOPPOSITE SIDE. HINGE SCREWS. CAUTION: Internal duct joints must be secured with tape, otherwise they may separate and cause a safety hazard. A