Summary of the content on the page No. 1
Summary of the content on the page No. 2
This page is intentionally left blank.
Summary of the content on the page No. 3
Preface Fujitsu would like to thank you for purchasing our ETERNUS DX60 S2 Disk storage system. The ETERNUS DX60 S2 Disk storage system is designed to be connected to Fujitsu (PRIMEQUEST or PRIMERGY) or non-Fujitsu servers. This manual describes the environmental requirements that are necessary to install and use the ETERNUS DX60 S2 Disk storage system. This manual is intended for use of ETERNUS DX60 S2 Disk storage system in regions other than Japan. Please carefully review the information o
Summary of the content on the page No. 4
About this Manual Organization This document is composed of the following four chapters: ● Chapter 1 Hardware Configurations This chapter describes the main components and the relative optional products that are installed in the ETERNUS DX60 S2 Disk storage system. ● Chapter 2 ETERNUS DX Disk Storage System Installation This chapter describes the installation specifications, the installation environment, and the power requirements. ● Chapter 3 Connections This chapter describes the conf
Summary of the content on the page No. 5
About this Manual Warning Notations Warning signs are shown throughout this manual in order to prevent injury to the user and/or material damage. These signs are composed of a symbol and a message describing the recom- mended level of caution. The following explains the symbol, its level of caution, and its meaning as used in this manual. This symbol indicates the possibility of minor or moderate personal CAUTION injury, as well as damage to the ETERNUS DX Disk storage system and/or to other
Summary of the content on the page No. 6
Table of Contents Chapter 1 Hardware Configurations ......................................................11 1.1 Controller Enclosure ......................................................................................... 11 1.1.1 Controllers ................................................................................................................................. 15 1.1.2 Power Supply Units .................................................................................................
Summary of the content on the page No. 7
Table of Contents Chapter 4 Rack and Optional Product Installation ...............................53 4.1 Rack Installation Requirements ....................................................................... 53 4.2 Installable Racks .............................................................................................. 54 4.2.1 Fujitsu Racks ............................................................................................................................. 54 4.2.2 Non-Fujitsu Ra
Summary of the content on the page No. 8
List of Figures Figure 1.1 Front view of a 2.5" type controller enclosure............................................................................ 11 Figure 1.2 Rear view of a 2.5" type controller enclosure (single-controller type)........................................ 12 Figure 1.3 Rear view of a 2.5" type controller enclosure (dual-controller type) .......................................... 12 Figure 1.4 Top view of a 2.5" type controller enclosure.........................................
Summary of the content on the page No. 9
List of Figures Figure 3.12 Power control using a power synchronized unit (when connecting three or more servers) ...... 51 Figure 4.1 Unit installation area .................................................................................................................. 55 Figure 4.2 Installation diagram for 2.5" disks.............................................................................................. 58 Figure 4.3 Installation diagram for 3.5" disks..................................
Summary of the content on the page No. 10
List of Tables Table 1.1 Host interface port specifications............................................................................................... 16 Table 1.2 DI port specifications ................................................................................................................. 17 Table 1.3 LAN port specifications.............................................................................................................. 17 Table 1.4 PWC port specifications ...........
Summary of the content on the page No. 11
Chapter 1 Hardware Configurations This chapter explains hardware configurations for the ETERNUS DX Disk storage system. 1.1 Controller Enclosure This section explains the main components in the controller enclosure. The controller enclosure contains disks installed in the front, and controllers and power supply units in the rear. Since the power supply units are redundant, operations can continue even if one of them fails. There are two models: a single-controller type and a dual-controller ty
Summary of the content on the page No. 12
Chapter 1 Hardware Configurations 1.1 Controller Enclosure ● Rear view • Single-controller type LAN (MNT) port LAN (RMT) port Cover PWC port Controller (CM#0) Power supply unit Power supply unit (PSU#1) (PSU#0) Host interface ports (0 (Left), 1 (Right)) DI (OUT) port Figure 1.2 Rear view of a 2.5" type controller enclosure (single-controller type) • Dual-controller type LAN (MNT) port LAN (MNT) port LAN (RMT) port LAN (RMT) port PWC port PWC port Controller (CM#0) Controller (CM#1) Power
Summary of the content on the page No. 13
Chapter 1 Hardware Configurations 1.1 Controller Enclosure ● Top view Figure 1.4 Top view of a 2.5" type controller enclosure ● Side view Figure 1.5 Side view of a 2.5" type controller enclosure ■ External views of a 3.5" type controller enclosure ● Front view Figure 1.6 Front view of a 3.5" type controller enclosure (with front cover) 3.5" disk Figure 1.7 Front view of a 3.5" type controller enclosure (without front cover) 13 ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning-
Summary of the content on the page No. 14
Chapter 1 Hardware Configurations 1.1 Controller Enclosure ● Rear view • Single-controller type LAN (MNT) port LAN (RMT) port Cover PWC port Controller (CM#0) Power supply unit Power supply unit (PSU#1) (PSU#0) Host interface ports (0 (Left), 1 (Right)) DI (OUT) port Figure 1.8 Rear view of a 3.5" type controller enclosure (single-controller type) • Dual-controller type LAN (MNT) port LAN (MNT) port LAN (RMT) port LAN (RMT) port PWC port PWC port Controller (CM#0) Controller (CM#1) Power
Summary of the content on the page No. 15
Chapter 1 Hardware Configurations 1.1 Controller Enclosure ● Top view Figure 1.10 Top view of a 3.5" type controller enclosure ● Side view Figure 1.11 Side view of a 3.5" type controller enclosure 1.1.1 Controllers The controller contains a CPU, cache memory, System Capacitor Unit (SCU), non-volatile mem- ory, host interface ports, drive interface (DI) ports, and LAN ports. The controller controls all operations in the ETERNUS DX Disk storage system. ■ Cache memory Cache memory enables high
Summary of the content on the page No. 16
Chapter 1 Hardware Configurations 1.1 Controller Enclosure ■ Host interface ports Host interface ports are used to connect controllers to servers. Two host interface ports can be installed in the controller of an ETERNUS DX Disk storage sys- tem. FC, iSCSI, and SAS are available as host interface. ● FC model FC ports (0 (Left), 1 (Right)) Figure 1.12 Host interface port (FC model) ● iSCSI model iSCSI ports (0 (Left), 1 (Right)) Figure 1.13 Host interface port (iSCSI model) ● SAS model SAS p
Summary of the content on the page No. 17
Chapter 1 Hardware Configurations 1.1 Controller Enclosure ■ Drive interface ports A DI port is used to connect a drive enclosure. The following table shows the DI port specifications. Table 1.2 DI port specifications Transfer Interface Connector type Number of ports for each controller speed (max.) SAS 3Gbit/s miniSAS (SFF8088) 1 ■ LAN ports Two LAN ports (RJ-45) are installed in each controller. ● Regions other than EMEA&I Each LAN port is used for operation management (MNT port) and for
Summary of the content on the page No. 18
Chapter 1 Hardware Configurations 1.2 Drive Enclosures 1.1.2 Power Supply Units The power supply unit transforms input AC power from a power socket to DC power and supplies power to each component. Two power supply units are installed in each controller enclosure. Each power supply unit contains fans. Figure 1.15 Power supply unit (controller enclosure) 1.2 Drive Enclosures This section explains the main components in the drive enclosure. The drive enclosure contains disks installed in the
Summary of the content on the page No. 19
Chapter 1 Hardware Configurations 1.2 Drive Enclosures ● Rear view • Single-expander type This is not used. DI (IN) port Cover Expander (EXP#0) Power supply unit Power supply unit (PSU#0) (PSU#1) Figure 1.18 Rear view of a drive enclosure (single-expander type) • Dual-expander type These are not used. DI (IN) ports Expander (EXP#1) Expander (EXP#0) Power supply unit Power supply unit (PSU#0) (PSU#1) Figure 1.19 Rear view of a drive enclosure (dual-expander type) ● Top view Figure 1.20 Top v
Summary of the content on the page No. 20
Chapter 1 Hardware Configurations 1.2 Drive Enclosures ● Side view Figure 1.21 Side view of a drive enclosure 1.2.1 Expanders The expander is a component that controls the interaction between the controller and the disks. DI (IN) port This is not used. Figure 1.22 Expander (drive enclosure) ■ Drive interface ports A DI port is used to connect a controller enclosure. The following table shows the DI port specifications. Table 1.5 DI port specifications Transfer Interface Connector type Numbe