Summary of the content on the page No. 1
MANUAL ADDENDUM
ULTRA SENSITIVITY MODEL
M200EU
NO/NO /NOx ANALYZER
2
(Addendum to M200E Manual PN 04410)
Teledyne Advanced Pollution Instrumentation
9480 Carroll Park Drive
San Diego, CA 92121-5201
USA
Toll-free Phone: 800-324-5190
Phone: 858-657-9800
Fax: 858-657-9816
Email: api-sales@teledyne.com
Website: http://www.teledyne-api.com/
05385 Rev C
Copyright 2009-2010 DCN 5731
Teledyne Advanced Pollution Instrumentation 14 May 2010
Summary of the content on the page No. 2
Summary of the content on the page No. 3
Ultra Sensitivity Model M200EU NO/NO /NOx Analyzer Addendum to M200E 2 TABLE OF CONTENTS 1. Overview.................................................................................................................... 1 2. Specifications, Agency Approvals, and Warranty..................................................... 2 3. Pneumatics................................................................................................................. 4 4. Spare Parts List...................
Summary of the content on the page No. 4
Summary of the content on the page No. 5
Ultra Sensitivity Model M200EU NO/NO /NOx Analyzer Addendum to M200E 2 1. OVERVIEW The model M200EU is a close derivative of the Model 200E NOx Analyzer. The main differences are as follows. The M200EU is more sensitive at low NOx levels than a standard 200E. The instrument has a user selectable full scale range of 0-5 PPB to 0-2000 PPB of NOx. The reaction cell is gold plated. In addition, there is a pre-reactor, which allows the measurements of any hydrocarbon interferents in t
Summary of the content on the page No. 6
Ultra Sensitivity Model M200EU NO/NO /NOx Analyzer Addendum to M200E 2 2. SPECIFICATIONS, AGENCY APPROVALS, AND WARRANTY Min/Max Range Min: 0-5 ppb of Full Scale (Physical Analog Output) Max 0-2000 ppb of Full Scale 3 Measurement Units ppb, ug/m (user selectable Single, independent or auto ranges) 1 Noise at Zero <25 ppt RMS 1 Noise at Span <0.25% RMS of reading above 50 ppb 1 Lower Detectable Limit 50 ppt RMS <0.1 ppb / 24 hours 2 Zero Drift <0.2 ppb / 7 days <0.5% of reading or
Summary of the content on the page No. 7
Ultra Sensitivity Model M200EU NO/NO /NOx Analyzer Addendum to M200E 2 COM 1: RS-232; Serial I/O COM 2: RS-232 or RS-485 (Ethernet interface available) Baud Rate: 300-115200 4 Environmental Installation Category (Over-voltage Category) II, Pollution Degree 2 US EPA: Reference Method Number RFNA 1194-099 Certifications CE: EN61326 (1997 w/A1:98) Class A, FCC Part 15 Subpart B Section 15.107 Class A, ICES-003 Class A (ANSI C63.4 1992) & AS/NZS 3548 (w/A1 &A2;97) Class A (1) As define
Summary of the content on the page No. 8
Ultra Sensitivity Model M200EU NO/NO /NOx Analyzer Addendum to M200E 2 3. PNEUMATICS Refer to the following pneumatic diagram. It shows the internal pneumatics of the M200EU in its standard configuration, along with the optional Zero/Span valves. The sample flow is about 1000 cc/min. Also during Auto Zero mode, the sample gas is routed through a pre-reactor before the mixture goes through the reaction cell. Since the reaction rate constant between NO and ozone is several time faster than
Summary of the content on the page No. 9
Ultra Sensitivity Model M200EU NO/NO /NOx Analyzer Addendum to M200E 2 4. SPARE PARTS LIST Note: Only parts different from M200E are listed below. Refer to the M200E users manual for the common spare parts. Part Number Description 011340800 Assy, Sensor, M200EU 024600100 Assy, Prereactor NO/NOx valve, M200EU 011420700 Assy, NOx cell, Gold plated, M200EU 011440200 Assy, PMT, M200AU/EU 041800600 PCA, PMT Preamp, VR, M200EU 001270001 Manifold, Gold Plated, NOx 001330001 Sleeve, Gold Pl