Invacare MicroAir MA60 user manual

User manual for the device Invacare MicroAir MA60

Device: Invacare MicroAir MA60
Category: Camping Equipment
Manufacturer: Invacare
Size: 0.52 MB
Added : 8/22/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Invacare MicroAir MA60. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Invacare MicroAir MA60.

For your convenience

If looking through the Invacare MicroAir MA60 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Invacare MicroAir MA60 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Invacare MicroAir MA60 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Invacare MicroAir MA60 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Invacare MicroAir MA60 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Invacare MicroAir MA60. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Owner’s Operator and Maintenance Manual
MA60 Series
MA60 Alternating Pressure
System
MA65 Alternating Pressure
On-Demand Low Air Loss
System
DEALER: This manual MUST be given to
the user of the product.
USER: BEFORE using this product, read this
manual and save for future reference.
For more information regarding
Invacare products, parts, and services,
please visit www.invacare.com

Summary of the content on the page No. 2

SPECIAL NOTES  WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as owner’s manuals, service manuals or instruction sheets supplied with this product or optional equipment. If you are unable to understand the warnings, cautions or instructions, contact a healthcare professional, dealer or technical personnel before attempting to use this equipment - otherw

Summary of the content on the page No. 3

TABLE OF CONTENTS TABLE OF CONTENTS SPECIAL NOTES ................................................................................2 REGISTER YOUR PRODUCT ............................................................... 4 TYPICAL PRODUCT PARAMETERS .................................................... 5 Electrical Parameters .................................................................................................................................5 Performance Parameters ......................

Summary of the content on the page No. 4

TABLE OF CONTENTS TABLE OF CONTENTS Preparing for CPR Procedure................................................................................................................20 About Power Outage and Transportation .........................................................................................20 SECTION 3—MAINTENANCE AND TROUBLESHOOTING ................... 21 Cleaning the System............................................................................................................

Summary of the content on the page No. 5

TYPICAL PRODUCT PARAMETERS TYPICAL PRODUCT PARAMETERS Electrical Parameters MA60/MA65 INPUT VOLTAGE AC: 90 V INPUT FREQUENCY: 60 Hz CURRENT: 1 A MAXIMUM POWER CONSUMPTION: 30 ± 10 W CIRCUIT PROTECTION: Dual fused, 250 V, 1 A fast blow fuses MODE OF OPERATION: Continuous Performance Parameters MA60/MA65 WEIGHT CAPACITY STANDARD MATTRESS: 350 lbs BARIATRIC MATTRESS: 1000 lbs PRESSURE ZONE: 2 MAXIMUM FLOW: 50 ± 15 LPM MAXIMUM FLOW PRESSURE: 35 ± 5 mmHg MAXIMUM FLOW TIMER: 30 minutes SUPPORT SURFA

Summary of the content on the page No. 6

TYPICAL PRODUCT PARAMETERS Environmental Parameters MA60/MA65 OPERATING CONDITIONS AMBIENT TEMPERATURE: 50° - 95° F RELATIVE HUMIDITY: 30% - 75% Non-Condensing ATMOSPHERIC PRESSURE: 70 - 106 kPa STORAGE AND SHIPPING CONDITIONS AMBIENT TEMPERATURE: -40° - 158° F RELATIVE HUMIDITY: 10% - 100% ATMOSPHERIC PRESSURE: 50 - 106 kPa MA60 Series 6 Part No 1148137

Summary of the content on the page No. 7

LABEL LOCATION LABEL LOCATION DANGER-EXPLOSION HAZARD: DO NOT use in the presence of flammable anesthetics. CAUTION: Equipment should be connected to a properly grounded receptacle (3-prong). Risk of Electrical shock. DO NOT remove back. Disconnect air hose before administering CPR. NOTE: This label is on the back of the unit and also contains the serial number.  WARNING Patient entrapment with bed side rails may cause injury or death. Mattress MUST fit bed frame and side rails snugly to

Summary of the content on the page No. 8

SECTION 1—GENERAL GUIDELINES SECTION 1—GENERAL GUIDELINES  WARNING SECTION 1 - GENERAL GUIDELINES contains important information for the safe operation and use of this product. Contraindications Always consult the patient’s physician before using the MA60 and MA65 systems. Safety Instructions The MA60 and MA65 systems MUST be installed on medical bed frames with side rails. The side rails must be in the raised position whenever a patient is on the bed. Controls on the footboard may be obstruc

Summary of the content on the page No. 9

SECTION 1—GENERAL GUIDELINES Fire Hazard  DANGER Smoking DO NOT SMOKE while using this device. This system uses room air for circulation through the mattress. A cigarette can burn a hole in the bed surface and cause damage to the mattress. Also, patient clothing, bed sheets, etc. may be combustible and cause a fire. Failure to observe this warning can result in severe fire, property damage and cause physical injury or death. Smoking by visitors in the room will contaminate the system. There

Summary of the content on the page No. 10

SECTION 2—OPERATION SECTION 2—OPERATION CAUTION The control unit and mattress on the MA60 series are designed to be used as a sys- tem. DO NOT replace mattresses or control units with other models or other brands. Otherwise, damage to the system may occur. Contact your supplier to get the correct replacement if needed. Installing the Powered Mattress CAUTION DO NOT strap the mattress to the bed frame at the head and foot ends. Secure ALL mattress straps. Secure the straps to the bed deck at t

Summary of the content on the page No. 11

SECTION 2—OPERATION Head End Powered Mattress Buckle Straps Foot End Hose FIGURE 2.1 Installing the Powered Mattress Installing the Side Rails  WARNING Patient entrapment with bed side rails may cause injury or death. Mattress MUST fit bed frame and side rails snugly to prevent patient entrapment. Follow the manu- facturer’s instructions. Monitor patient frequently. Read and understand the Owner’s/Operator’s Manual prior to using this equipment. Invacare product manu- als are available at

Summary of the content on the page No. 12

SECTION 2—OPERATION Connecting the Hose  CAUTION Ensure that the hose connecting the control unit to the mattress is routed such that it cannot be stepped on, kinked, squeezed or otherwise damaged. NOTE: For this procedure, refer to FIGURE 2.2. 1. Locate the hose at the foot end of the mattress. 2. Locate the control unit connectors on the right side of the control unit. 3. Squeeze and hold the tabs on the hose connectors. 4. Insert the hose connectors into the control unit connectors. 5. Push

Summary of the content on the page No. 13

SECTION 2—OPERATION Connecting the Power Cord  WARNING DO NOT alter plug to fit a non-conforming outlet. Instead, have an electrician install a properly grounded 3-prong outlet. Failure to use the correct plug and outlet can result in a potential safety hazard. CAUTION Ensure that the power cord of the control unit is not pinched, or has any objects placed on it, and also ensure it is not located where it can be stepped on or tripped over. 1. Examine the hospital grade power cord supplied w

Summary of the content on the page No. 14

SECTION 2—OPERATION Using the Front Panel NOTE: For this procedure, refer to FIGURE 2.3. DETAIL “A” - MA60 FRONT PANEL Low Pressure Fowler Power Alternating Power LED Button Button Pressure Button Fail LED Lock/Alarm Static Button Max Inflate Button Soft Button LCD Display Button Firm Button DETAIL “B” - MA65 FRONT PANEL Low Pressure Fowler Power Power Alternating LED Button Fail LED Button Pressure Button Lock/Alarm Static Button Mode Button Button Soft Button LCD Display (Max Infl

Summary of the content on the page No. 15

SECTION 2—OPERATION Alternating Pressure Button 1. Press the Alternating Pressure button ( ) to select between one of four alternating pressure times - 5, 10, 15 and 20 minutes. NOTE: The alternating pressure times indicate the frequency of deflation or inflation of half of the air cushions (even or odd numbered). For example, 10 minutes is selected. In this example, the even numbered air cushions in the mattress will deflate, while the odd numbered cushions remain at constant pressure. Whe

Summary of the content on the page No. 16

SECTION 2—OPERATION Firm/Soft Buttons 1. Select comfort pressure settings by pressing Firm ( ) or Soft ( ) button. • Soft Button - Pressing this button reduces the pressure setting in the mattress. • Firm Button - Pressing this button increase the pressure setting in the mattress. NOTE: The patient comfort pressure ranges from Soft (level 0 = 6±4 mmHg) to Firm (level 9 = 32±6 mmHg). The Comfort Control LED displays the patient comfort pressure levels from 0 to 9 and provides a guide to the car

Summary of the content on the page No. 17

SECTION 2—OPERATION Max Inflate/Low Air Loss Button MA60 System 1. Press the Max Inflate button ( ) to select the max inflate mode. • Max Inflate Mode - In this mode, the mattress inflates rapidly to maximum firmness (pressurized to 35 ± 6 mmHg). A series of beeps sound every three minutes as a reminder that the Max Inflate mode is active. After 30 minutes, the Max Inflate mode deactivates and the control unit defaults to the previous setting. NOTE: It takes 5-10 minutes for the mattress to

Summary of the content on the page No. 18

SECTION 2—OPERATION • Alarm Silence mode - Pressing this button silences the alarm that sounds in the event of power failure or when the hose is disconnected from the control unit. NOTE: The Alarm LED illuminates when in this mode. Power Fail LED In the event of power outage, an alarm sounds and Power Fail LED flashes AMBER. The control unit has internal memory and retains the previous settings during the power outage. NOTE: During a power outage, the mattress retains the air as long as the m

Summary of the content on the page No. 19

SECTION 2—OPERATION 9. Verify that the patient has not bottomed out by performing the following steps: A. Ensure that the patient is lying flat on his/her back in the middle of the mattress. B. Place four fingers between the air cushions directly underneath the sacral region of the patient’s body. C. Ensure that there is 3 to 4-finger width clearance between the bottom of the patient and the mattress surface. D. Adjust the comfort setting, if needed. E. Wait five minutes for the mattress press

Summary of the content on the page No. 20

SECTION 2—OPERATION Transferring Patient From/To a Wheelchair  WARNING ALWAYS engage the wheel locks of the bed and the wheel locks of the wheelchair before transferring the patient between the bed and the wheelchair. 1. Engage the wheel locks of the bed. Refer to the owner’s manual provided with the bed. 2. Engage the wheel locks of the wheelchair, if applicable. Refer to the owner’s manual provided with the wheelchair. 3. Press the Max Inflate button to achieve maximum mattress pressure. 4.


Alternative user manuals
# User manual Category Download
1 Invacare Alternating Pressure Air Mattress MNS400-B User manual Camping Equipment 3
2 Invacare Alternating Pressure Air Mattress MNS400-N User manual Camping Equipment 0
3 Invacare Alternating Pressure Air Mattress MNS400 User manual Camping Equipment 22
4 Invacare Alternating Pressure Air Mattress MNS400-S User manual Camping Equipment 0
5 Invacare APM User manual Camping Equipment 1
6 Invacare CareGuard CG9701 User manual Camping Equipment 1
7 Invacare BAR750 User manual Camping Equipment 0
8 Invacare CG8000 User manual Camping Equipment 0
9 Invacare Bed Rails User manual Camping Equipment 4
10 Invacare CareGuard CGGFMO User manual Camping Equipment 0
11 Invacare BariatricBed User manual Camping Equipment 0
12 Invacare CG10180CA User manual Camping Equipment 0
13 Invacare CareGuard 8000 User manual Camping Equipment 0
14 Invacare CG101080 User manual Camping Equipment 0
15 Invacare ICCG 1143214 User manual Camping Equipment 0
16 Philips 29PT5307 User manual Camping Equipment 0
17 Badger Basket 08100 User manual Camping Equipment 0
18 Big Agnes Classic Series Lost Dog 50 User manual Camping Equipment 1
19 Big Agnes Classic Series Farwall 0 User manual Camping Equipment 1
20 Big Agnes Classic Series Cross Mountain 40 User manual Camping Equipment 1