Invacare MA80 user manual

User manual for the device Invacare MA80

Device: Invacare MA80
Category: Camping Equipment
Manufacturer: Invacare
Size: 0.58 MB
Added : 8/22/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Invacare MA80. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Invacare MA80.

For your convenience

If looking through the Invacare MA80 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Invacare MA80 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Invacare MA80 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Invacare MA80 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Invacare MA80 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Invacare MA80. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Owner’s Operator and Maintenance Manual
MA80 Series
MA80 True Low Air Loss
System
MA85 Five-Zone Alternating
Pressure and True Low Air
Loss System
DEALER: This manual MUST be given to
the user of the product.
USER: BEFORE using this product, read this
manual and save for future reference.
For more information regarding
Invacare products, parts, and services,
please visit www.invacare.com

Summary of the content on the page No. 2

SPECIAL NOTES  WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as owner’s manuals, service manuals or instruction sheets supplied with this product or optional equipment. If you are unable to understand the warnings, cautions or instructions, contact a healthcare professional, dealer or technical personnel before attempting to use this equipment - otherw

Summary of the content on the page No. 3

TABLE OF CONTENTS TABLE OF CONTENTS SPECIAL NOTES ................................................................................2 REGISTER YOUR PRODUCT ............................................................... 4 TYPICAL PRODUCT PARAMETERS .................................................... 5 Electrical Parameters.............................................................................................................................5 Performance Parameters............................

Summary of the content on the page No. 4

TABLE OF CONTENTS TABLE OF CONTENTS Transferring Patient From/To a Gurney .............................................................................................19 Transferring Patient From/To a Wheelchair......................................................................................19 Preparing for CPR Procedure................................................................................................................19 SECTION 3—MAINTENANCE AND TROUBLESHOOTING ................

Summary of the content on the page No. 5

TYPICAL PRODUCT PARAMETERS TYPICAL PRODUCT PARAMETERS Electrical Parameters MA80/MA85 INPUT VOLTAGE AC: 90 V INPUT FREQUENCY: 60 Hz CURRENT: 2 A MAXIMUM POWER CONSUMPTION: 150 ± 10 W CIRCUIT PROTECTION: Dual fused, 250 V, 5 A fast blow fuses MODE OF OPERATION: Continuous Performance Parameters MA80 MA85 WEIGHT CAPACITY STANDARD MATTRESS: 350 lbs BARIATRIC MATTRESS: 1000 lbs PRESSURE ZONE: 5 MAXIMUM FLOW: 1275 ± 100 LPM MAXIMUM PRESSURE: 35 ± 5 mmHg MAXIMUM FLOW TIMER: 15 minutes SUPPORT SURFAC

Summary of the content on the page No. 6

TYPICAL PRODUCT PARAMETERS Environmental Parameters MA80/MA85 OPERATING CONDITIONS AMBIENT TEMPERATURE: 50° - 104° F RELATIVE HUMIDITY: 30% - 75% Non-Condensing ATMOSPHERIC PRESSURE: 70 - 106 kPa STORAGE AND SHIPPING CONDITIONS AMBIENT TEMPERATURE: -40° - 158° F RELATIVE HUMIDITY: 10% - 100% ATMOSPHERIC PRESSURE: 50 - 106 kPa MA80 Series 6 Part No 1148138

Summary of the content on the page No. 7

LABEL LOCATION LABEL LOCATION DANGER-EXPLOSION HAZARD: DO NOT use in the presence of flammable anesthetics. CAUTION: Equipment should be connected to a properly grounded receptacle (3-prong). Risk of Electrical shock. DO NOT remove back. Disconnect air hose before administering CPR. NOTE: This label is on the back of the unit and also contains the  ATTENTION serial number. Clean Filter Every 5 months and Whenever Dirty. Remove Filter, Wash, Dry & Replace.  WARNING Patient entrapment wit

Summary of the content on the page No. 8

SECTION 1—GENERAL GUIDELINES SECTION 1—GENERAL GUIDELINES  WARNING SECTION 1 - GENERAL GUIDELINES contains important information for the safe operation and use of this product. Contraindications ALWAYS consult the patient’s physician before using the MA80 and MA85 systems. Installation The MA80 and MA85 systems MUST be installed on medical bed frames with side rails. The side rails MUST be in the raised position whenever a patient is on the bed. Controls on the footboard may be obstructed by

Summary of the content on the page No. 9

SECTION 1—GENERAL GUIDELINES Fire Hazard  DANGER Smoking DO NOT SMOKE while using this device. This system uses room air for circulation through the mattress. A cigarette can burn a hole in the bed surface and cause damage to the mattress. Also, patient clothing, bed sheets, etc. may be combustible and cause a fire. Failure to observe this warning can result in severe fire, property damage and cause physical injury or death. Smoking by visitors in the room will contaminate the system. There

Summary of the content on the page No. 10

SECTION 2—OPERATION SECTION 2—OPERATION CAUTION The control unit and mattress on the MA80 series are designed to be used as a system. DO NOT replace mattresses or control units with other models or other brands. Otherwise, damage to the system may occur. Contact your supplier to get the correct replacement if needed. Installing the Mattress Replacement System CAUTION DO NOT strap the mattress to the bed frame at the head and foot ends. Secure ALL mattress straps. Secure the straps to the bed

Summary of the content on the page No. 11

SECTION 2—OPERATION Head End Powered Mattress Buckle Straps Hose Foot End FIGURE 2.1 Installing the Mattress Replacement System Installing the Side Rails  WARNING Patient entrapment with bed side rails may cause injury or death. Mattress MUST fit bed frame and side rails snugly to prevent patient entrapment. Follow the manufacturer’s instructions. Monitor patient frequently. Read and understand the Owner’s/Operator’s Manual prior to using this equipment. Invacare product manuals are avai

Summary of the content on the page No. 12

SECTION 2—OPERATION Connecting the Hose CAUTION Ensure that the hose connecting the control unit to the mattress is routed such that it cannot be stepped on, kinked, squeezed or otherwise damaged. NOTE: For this procedure, refer to FIGURE 2.3. 1. Locate the hose at the foot end of the mattress. 2. Locate the control unit connector on the right side of the control unit. 3. Lift and hold the connector cover up. 4. Push the hose connector (Detail “A”) onto the control connector. 5. Ensure the hose

Summary of the content on the page No. 13

SECTION 2—OPERATION Connecting the Power Cord  WARNING DO NOT alter plug to fit a non-conforming outlet. Instead, have an electrician install a properly grounded outlet. Failure to use the correct plug and outlet can result in a potential safety hazard. CAUTION Ensure that the power cord of the control unit is not pinched, or has any objects placed on it, and also ensure it is not located where it can be stepped on or tripped over. NOTE: For this procedure, refer to FIGURE 2.4. 1. Examine t

Summary of the content on the page No. 14

SECTION 2—OPERATION Using the Front Panel NOTE: For this procedure, refer to FIGURE 2.5. DETAIL “A” - MA80 FRONT PANEL Low Pressure Fowler Power LED Power Fail Button Pulse Button Button LED Lock/Alarm Static Button Max Inflate Soft Button Button LCD Button Firm Button Display DETAIL “B” - MA85 FRONT PANEL Low Pressure Fowler Power Fail Power Alternating LED Button LED Button Pressure Button Lock/Alarm Static Button Max Inflate Button Soft Button LCD Firm Button Button Display FIGU

Summary of the content on the page No. 15

SECTION 2—OPERATION Pulse Button (MA80) 1. Press the Pulse button ( ) to Turn on Pulse mode and select one of four Pulse Times - 1, 3, 5 or 10 minutes. NOTE: The pulse times are 1, 3, 5 or 10 minutes. The pulse times indicate the time between each low pulse. For example, if 5 minutes is selected, all the air cushions in the mattress will inflate for 5 minutes (the selected time) to the selected comfort setting and then drop 20% pressure for 20 seconds. Alternating Pressure Button (MA85) 1.

Summary of the content on the page No. 16

SECTION 2—OPERATION Static Button 1. Press the Static button ( ) to select the static mode and maintain the mattress at constant pressure. NOTE: The Static LED is illuminated GREEN. Firm/Soft Buttons 1. Select comfort pressure settings by pressing Firm ( ) or Soft ( ) buttons. • Soft Button - Pressing this button reduces the pressure in the mattress. • Firm Button - Pressing this button increases the pressure in the mattress. NOTE: The patient comfort pressure ranges from Soft (level 0 = 6±4 mm

Summary of the content on the page No. 17

SECTION 2—OPERATION 5. Perform one of the following: • Cancel - Press the Fowler button to exit Fowler Transmitter Setup without linking to a transmitter. • Save - Wait 60 seconds without pressing a key. Max Inflate Button 1. Press the Max Inflate button ( ) to select the max inflate mode and inflate the mattress rapidly to maximum firmness (pressurized to 35 ± 6 mmHg). A series of beeps sound every three minutes as a reminder that the Max Inflate mode is active. After 30 minutes, the Max I

Summary of the content on the page No. 18

SECTION 2—OPERATION Powering Up the System NOTE: For this procedure, refer to FIGURE 2.5 on page 14. 1. Turn on the power to the system by pressing the Power button on the control unit. NOTE: Once the button is released, a GREEN LED illuminates when the unit is on. Placing the Patient on the Mattress 1. Press the Max Inflate button to turn on the control unit to maximum flow. NOTE: In this mode, the Max Inflate LED lights up. 2. After the mattress is fully inflated, place the patient on the bed

Summary of the content on the page No. 19

SECTION 2—OPERATION Transferring Patient From/To a Gurney  WARNING ALWAYS engage the wheel locks of the bed and the wheel locks of the gurney before transferring the patient between the bed and the gurney. 1. Engage the wheel locks of the bed. Refer to the owner’s manual provided with the bed. 2. Engage the wheel locks of the gurney. Refer to the owner’s manual provided with the gurney. 3. Press the Max Inflate button to achieve maximum mattress pressure. 4. Raise or lower the bed to match th

Summary of the content on the page No. 20

SECTION 2—OPERATION DETAIL “A” Connector Cover Control Unit Connector Control Unit DETAIL “B” Hose Connector Holes FIGURE 2.6 Preparing for CPR Procedure MA80 Series 20 Part No 1148138


Alternative user manuals
# User manual Category Download
1 Invacare Alternating Pressure Air Mattress MNS400-B User manual Camping Equipment 3
2 Invacare Alternating Pressure Air Mattress MNS400-N User manual Camping Equipment 0
3 Invacare Alternating Pressure Air Mattress MNS400 User manual Camping Equipment 22
4 Invacare Alternating Pressure Air Mattress MNS400-S User manual Camping Equipment 0
5 Invacare APM User manual Camping Equipment 1
6 Invacare CareGuard CG9701 User manual Camping Equipment 1
7 Invacare BAR750 User manual Camping Equipment 0
8 Invacare CG8000 User manual Camping Equipment 0
9 Invacare Bed Rails User manual Camping Equipment 4
10 Invacare CareGuard CGGFMO User manual Camping Equipment 0
11 Invacare BariatricBed User manual Camping Equipment 0
12 Invacare CG10180CA User manual Camping Equipment 0
13 Invacare CareGuard 8000 User manual Camping Equipment 0
14 Invacare CG101080 User manual Camping Equipment 0
15 Invacare ICCG 1143214 User manual Camping Equipment 0
16 Philips 29PT5307 User manual Camping Equipment 0
17 Badger Basket 08100 User manual Camping Equipment 0
18 Big Agnes Classic Series Lost Dog 50 User manual Camping Equipment 1
19 Big Agnes Classic Series Farwall 0 User manual Camping Equipment 1
20 Big Agnes Classic Series Cross Mountain 40 User manual Camping Equipment 1