Summary of the content on the page No. 1
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 1
INSTRUCTION MANUAL
Automatic Wrist
Blood Pressure Monitor
Model 6021REL
ENGLISH SPANISH
Summary of the content on the page No. 2
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 2 B TABLE OF CONTENTS Before Using the Monitor Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Operating the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Before Taking a Measurement . .
Summary of the content on the page No. 3
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 3 Before Using the Monitor INTRODUCTION ® Thank you for purchasing the ReliOn 6021REL Automatic Wrist Blood Pressure Monitor. Fill in for future reference. DATE PURCHASED: _____________ SERIAL NUMBER: _______________ Staple your purchase receipt here The monitor is compact and easy-to-use at home, at work, and during travel. Perfect for people who frequently monitor their own blood pressure. Your new digital blood pressure monitors us
Summary of the content on the page No. 4
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 4 SAFETY INFORMATION To assure the correct use of the product, basic safety measures should always be followed including the warnings and cautions listed in this instruction manual. SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL Indicates a potentially hazardous situation which, if not avoided, could result in death WARNING or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or C
Summary of the content on the page No. 5
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 5 SAFETY INFORMATION OPERATING THE DEVICE (continued) Operate the device only as intended. Do not use the device for any other purpose. Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution. Do not use a cellular phone near the device. It may result in an operational failure. Use only 1.5V “AAA” alkaline batteries with this device. Do n
Summary of the content on the page No. 6
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 6 BEFORE TAKING A MEASUREMENT To ensure a reliable reading follow these recommendations: 1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement. 2. Stress raises blood pressure. Avoid taking measurements during stressful times. 3. The cuff can be applied to your left or right wrist. 4. Measurements should be taken in a q
Summary of the content on the page No. 7
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 7 BEFORE TAKING A MEASUREMENT The American Heart Association (AHA) recommends the following guideline for upper limit of normal for home blood pressure readings: AHA Home Guideline for Upper Limit of Normal BP Systolic Blood Pressure 135 mmHg Diastolic Blood Pressure 85 mmHg This is a general guideline because blood pressure depends on age and morbidity. The AHA recommends a lower home blood pressure goal for certain patients, includi
Summary of the content on the page No. 8
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 8 Operating Instructions KNOW YOUR UNIT Main Unit: Wrist Cuff Display ON/OFF START Battery Compartment Components: Storage Case Two “AAA” Alkaline Batteries INSTRUCTION MANUAL Automatic Wrist Blood Pressure Monitor Model 6021REL Instruction Manual 8 ENGLISH SPANISH
Summary of the content on the page No. 9
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 9 UNIT DISPLAY Systolic Blood Pressure Diastolic Blood Pressure Heartbeat Symbol Pulse Display Low Battery Indicator Cuff Deflation Symbol 9
Summary of the content on the page No. 10
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 10 BATTERY INSTALLATION 1. Press both sides of the battery cover and lift the cover off in the direction of the arrow. 2. Install 2 “AAA” size batteries so the + (positive) and - (negative) polarities match the polarities of the battery compartment as indicated. 3. Replace the Battery Cover. Make sure the battery cover is securely in place. 10
Summary of the content on the page No. 11
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 11 BATTERY INSTALLATION BATTERY REPLACEMENT Low Battery Indicator Initial Set-Up When the Low Battery Indicator appears on the display screen, turn the monitor off and remove all the batteries. Replace with two new batteries at the same time. Long-life alkaline batteries are recommended. WARNING If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately. NOTE: The batteries
Summary of the content on the page No. 12
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 12 APPLYING THE WRIST CUFF Wrapping the wrist cuff is one of the most important points for taking a correct measurement. APPLYING THE CUFF ON THE LEFT WRIST 1. Roll up sleeve. Make sure your sleeve is not rolled up too tightly on your arm. This may constrict the flow of blood in your arm. 2. Wrap the cuff directly against your skin. Do not apply over clothing. Place the cuff over your left wrist with your left thumb facing upward. 3.
Summary of the content on the page No. 13
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 13 TAKING A MEASUREMENT 1. Sit comfortably in a chair with your feet flat on the floor. 2. Hold your arm across your chest at heart level. Hold your elbow firmly to avoid body movement. Sit still and do not talk or move during the measurement. 3. Press the ON/OFF START button. All symbols appear on the display. The cuff starts to inflate automatically. As the cuff inflates, the monitor automatically determines your ideal inflation l
Summary of the content on the page No. 14
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 14 TAKING A MEASUREMENT 4. After the monitor has detected your blood pressure and pulse rate, the cuff automatically deflates. Your blood pressure and pulse rate are displayed. 5. Press the ON/OFF START button to turn the monitor off. NOTE: The monitor will automatically turn off after two minutes. 14
Summary of the content on the page No. 15
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 15 Care and Maintenance CARE AND MAINTENANCE To keep your digital blood pressure monitor in the best condition and protect the unit from damage, follow the directions listed below: Do not forcefully bend the cuff. Do not fold tightly. Clean the monitor with a soft dry cloth. Do not use any abrasive or volatile cleaners. Do not attempt to clean the cuff. CAUTION Do not submerge the device or any of the components in water. Do not subj
Summary of the content on the page No. 16
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 16 ERROR INDICATORS AND TROUBLESHOOTING TIPS ERROR INDICATORS SYMBOL CAUSE CORRECTION Press the ON/OFF START button to turn the unit off. Remove the monitor from Movement during your wrist. Refer to measurement. “Taking a Measurement”. Wait 2-3 minutes. Take another measurement. Remove the monitor from your wrist. Read, “Applying The cuff is not the Wrist Cuff”. wrapped securely. Wait 2-3 minutes. Take another measurement. Replace
Summary of the content on the page No. 17
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 17 ERROR INDICATORS AND TROUBLESHOOTING TIPS TROUBLESHOOTING TIPS PROBLEM CAUSES AND SOLUTIONS Replace worn batteries. No power. Check the battery installation for No display appears on the unit. proper placement of the battery polarities. Blood pressure varies constantly. Many factors including stress, time of day, how you wrap the Measurements values appear cuff, may affect your blood too high or too low. pressure. Review the
Summary of the content on the page No. 18
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 18 FCC STATEMENT NOTE: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The product generates, uses, and can radiate radio frequency energy and, if not installed and used in
Summary of the content on the page No. 19
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 19 LIMITED WARRANTY ® Your ReliOn 6021REL Automatic Wrist Blood Pressure Monitor is warranted to be free from defects in materials and workmanship appearing within one year from the date of purchase, when used in accordance with the instructions provided with the monitor. The above warranty extends only to the original retail purchaser. We will, at our option, repair or replace without charge any monitor covered by the above warranty.
Summary of the content on the page No. 20
290238_Omron_HEM-6021-WM_EN_SP_r2.qxd 2/10/09 9:15 AM Page 20 SPECIFICATIONS Model: 6021REL (HEM-6021-WM) Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min. Accuracy/Calibration: Pressure: ±3mmHg Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Automatic rapid deflation Pressure Detection: Capacitive pressure sensor Measurement Method: Oscillometric method Power Source: Two “AAA” batteries Battery Life: Approximately 300 measu