Automatic Blood Pressure Monitor
1( +2
Model M6 AC
Türkçe
Instruction Manual
IM-HEM-7322-E-01-08/2013
2298870-5A
Summary of the content on the page No. 2
1 2 b b J N c d a O
Summary of the content on the page No. 3
A G K B C H L J D E I F H P V G Q W R X M Y S Z AA AB H T AC H O N AD AE U AF
Summary of the content on the page No. 4
English Français Deutsch Italiano Español Nederlands Automatic Blood Pressure Monitor 1( +2 Model M6 AC Türkçe Instruction Manual Check following components! Vérifier les composants suivants ! Controleer de volgende onderdelen! Prüfen Sie folgende Teile des Lieferumfangs! '
()* +/ 0! Controllare i componenti indicati di seguito!
!
" ¡Compruebe los siguientes componentes!
Summary of the content on the page No. 5
Contents Thank you for purchasing the OMRON M6 AC Automatic Blood Pressure Monitor. The OMRON M6 AC is a compact, fully automatic blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need of pressure pre-setting or re-inflation the device uses its advanced “IntelliSense” technology. Intended Use This device is a digital monitor intended for use in measuring blood pr
Summary of the content on the page No. 6
Important Safety Information Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. (General Usage) Consult your physician before using the device in pregnancy including pre-eclampsia, or if diagnosed with arrhythmia or arteriosclerosis. Do not use the device on the injured arm or the arm under medical treatment. Do not apply the arm cuff on the arm while being on an intravenous drip or blood transfusion. EN Consult your physician b
Summary of the content on the page No. 7
Important Safety Information If there are any abnormalities during the measurement, remove the arm cuff. Do not use this device on infants or persons who cannot express their intentions. Do not inflate the arm cuff more than necessary. Do not use the device for any purpose other than measuring blood pressure. Use only the approved arm cuff for this device. Use of other arm cuffs may result in incorrect measurement results. Do not use a mobile phone or other devices that emit electromagnetic fiel
Summary of the content on the page No. 8
Important Safety Information (Battery Usage) Do not insert the batteries with their polarities incorrectly aligned. Use only 4 “AA” alkaline or manganese batteries with this device. Do not use other types of batteries. Do not use new and used batteries together. Remove the batteries if the device will not be used for three months or more. General Precautions EN • Do not forcibly crease the arm cuff or the air tube excessively. • Do not press the air tube while taking a measurement. • To unplug
Summary of the content on the page No. 9
1. Know Your Device Open the rear cover page to read the following: The letter identifiers on the rear cover page correspond to those in the body of this page. Monitor Display A P Display Memory symbol B Q Cuff wrap guide lamp USER ID symbol C R Memory button Average value symbol D S Weekly average button Systolic blood pressure E T START/STOP button Diastolic blood pressure F U Up/Down buttons Heartbeat symbol (Flashes during measurement) G USER ID selection switch H V Date/Time setting button
Summary of the content on the page No. 10
1. Know Your Device Display Symbols Irregular Heartbeat Symbol ( ) Normal Heartbeat When the monitor detects an irregular rhythm two or more times during the Pulse measurement, the irregular heartbeat symbol ( ) will appear on the Blood pressure display with the measurement values. An irregular heartbeat rhythm is defined as a rhythm that is 25% less or 25% Irregular Heartbeat EN Short Long more than the average rhythm detected while the monitor is measuring the Pulse systolic and diastolic
Summary of the content on the page No. 11
1. Know Your Device Blood Pressure Colour Indicator If your systolic or diastolic pressure is above the standard range (135 mmHg for the systolic blood pressure and/or 85 mmHg for the diastolic blood pressure), the blood pressure colour indicator will light in “orange” when the measurement result is displayed. If they are within the standard range, the blood pressure colour indicator will light in “green”. The JNC7* Guideline recommends the following guideline. General Guidelines for Blood Pr
Summary of the content on the page No. 12
2. Preparation 2.1 Battery Installation 1. Remove the battery cover. 2. Insert 4 “AA” batteries as EN indicated in the battery compartment. 3. Replace the battery cover. Notes: • When the low battery symbol ( ) appears on the display, turn the monitor off, then replace all batteries at the same time. Long life alkaline batteries are recommended. • The measurement values continue to be stored in memory even after the batteries are replaced. • The supplied batteries may have a shorter life. Dis
Summary of the content on the page No. 13
2. Preparation 2.2 Using the AC Adapter 1. Insert the AC adapter plug into the AC adapter jack on the rear side of the monitor. 2. Plug the AC adapter into an electrical outlet. To disconnect the AC adapter, unplug the AC adapter from the electrical outlet first and then remove the AC adapter plug from the monitor. 8
Summary of the content on the page No. 14
2. Preparation Open the rear cover page to read the following: The letter identifiers on the rear cover page correspond to those in the body of this page. 2.3 Setting the Date and Time Set the monitor to the correct date and time before taking a measurement for the first time. EN H 1. Press the Date/Time setting ( ) button. V The year flashes on the Date/Time display. 2. Push or button to change the year. Push button to confirm the year and then the month flashes. Repeat the same steps to chan
Summary of the content on the page No. 15
3. Using the Device Open both the front and rear covers to read the following: The letter identifiers on the cover pages correspond to those in the body of this page. 3.1 Applying the Arm Cuff Remove tight-fitting clothing or tight rolled up sleeve from your left upper arm. Do not place the arm cuff over thick clothes. N J 1. Insert the air plug into the air jack securely. 2. Wrap the arm cuff firmly in place around your left upper arm. a The bottom edge of the arm cuff should be 1 to 2 cm a
Summary of the content on the page No. 16
3. Using the Device 3.2 How to Sit Correctly To take a measurement, you need to be relaxed and comfortably seated, under comfortable room temperature. Avoid bathing, drinking alcohol or caffeine, smoking, exercising or eating 30 minutes before taking a measurement. • Sit on a chair with your feet flat on the floor. EN c • Sit upright with your back straight. --- • Sit with your back and arm being supported. d • The arm cuff should be placed on your arm at the same level as your heart. --- 11
Summary of the content on the page No. 17
3. Using the Device 3.3 Taking a Measurement Notes: • To cancel a measurement, press the START/STOP button to release the air in the arm cuff. • Remain still while taking a measurement. The monitor is designed to take measurements and store the measurement values in the memory for 2 people using USER ID 1 and USER ID 2. 1. Select your USER ID (1 or 2). 2. Press the START/STOP button. The arm cuff starts to inflate automatically. START INFLATE DEFLATE COMPLETE If your systolic pressure is more
Summary of the content on the page No. 18
3. Using the Device 3. Remove the arm cuff. 4. Press the START/STOP button to turn the monitor off. The monitor automatically stores the measurement result in its memory. It will automatically turn off after 2 minutes. EN Note: Wait 2-3 minutes before taking another measurement. Waiting between measurements allows the arteries to return to the condition prior to taking a measurement. Using the Guest Mode The monitor stores measurement values for 2 users in the memory. The guest mode can be use
Summary of the content on the page No. 19
3. Using the Device 3.4 Using the Memory Function The monitor automatically stores the results up to 100 sets for each user (1 and 2). It can also calculate an average value based on the last 3 measurement values taken within 10 minutes. Notes: • If there are only 2 measurement values in the memory for that period, the average will be based on these 2 values. • If there is 1 measurement value in the memory for that period, this is displayed as the average. • If the memory is full, the monit
Summary of the content on the page No. 20
3. Using the Device To View the Average Value 1. Select your USER ID (1 or 2). 2. Press and hold the button for more than 3 seconds. EN Notes: • If the previous measurement was taken without setting the date and time, the average value is not calculated. • If there are no measurement values stored in the memory, the screen to the right is displayed. 15