LifeSource UA-702 user manual

User manual for the device LifeSource UA-702

Device: LifeSource UA-702
Category: Blood Pressure Monitor
Manufacturer: LifeSource
Size: 0.32 MB
Added : 12/15/2013
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for LifeSource UA-702. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with LifeSource UA-702.

For your convenience

If looking through the LifeSource UA-702 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual LifeSource UA-702 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual LifeSource UA-702 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
LifeSource UA-702 User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual LifeSource UA-702 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to LifeSource UA-702. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TM
Congratulations. You have purchased a LifeSource
state-of-the-art blood pressure monitor, one of the most
technologically advanced yet easy to use products
available in the marketplace today. This LifeSource
monitor is designed to make your daily regimen
useful, and convenient.
Physicians agree that daily self-monitoring of blood
pressure is an important way individuals can contribute
to maintaining their cardiovascular health and preventing
the serious consequences of hypertension left

Summary of the content on the page No. 2

TABLE OF CONTENTS WHAT DISPLAY SYMBOLS MEAN . . . . . . . . . . . . . . . . . . . . 3 MONITOR COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . 4 ? HOW 702 WORKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 BEFORE YOU START . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 SELECTING THE CORRECT CUFF . . . . . . . . . . . . . . . . . . . . . . 6 TAKING YOUR BLOOD PRESSURE . . . . . . . . . . . . . . . . 7 — 10 CHECK/ADJUST EXHAUST VELOCITY . . . . . . . . .

Summary of the content on the page No. 3

WHAT DISPLAY SYMBOLS MEAN ? Display Condition/ Recommended Symbol Cause Action Appears during measure- Remain still and refrain ment; blinks and beeps from talking; measurement ❤ MEASURING when pulse is detected. in progress. Appears on display prior to Press exhaust button to and during measurement. release air. Blinks if there is air in cuff ERROR at power up. Measurement begun, but Increase pressurization by pressure is not sufficient for 30 mmHg to 40 mmHg and reading. repeat measurement. RE

Summary of the content on the page No. 4

MONITOR COMPONENTS ? AIR SOCKET SYSTOLIC DIASTOLIC (PULSE) PRESSURE AND UA-702 PULSE DISPLAY DIGITAL BLOOD PRESSURE MONITOR MEASURING POWER PRESS EXHAUST RE-MEASURE BATTERY LOW RE-MEASURE CUFF POWER BUTTON AIR CONNECTOR CUFF INFLATOR BULB EXHAUST VALVE AND ADJUSTMENT SCREW BATTERY COMPARTMENT LifeSource Health Line (Toll-Free): 1-888-726-9966 4 ?

Summary of the content on the page No. 5

HOW 702 WORKS ? LifeSource Blood Pressure Monitors are easy to use, accurate and digitally display full measurement readouts. Our technology is based on the “oscillometric method” — a noninvasive blood pressure determination. The term “oscillation” refers to any measure of vibrations caused by the arterial pulse. The cuff is first inflated until the artery is fully occluded. Then, the monitor takes measurements while the cuff deflates. Our monitors exam- ine the pulsatile pressure generated

Summary of the content on the page No. 6

SELECTING THE CORRECT CUFF Using the correct cuff size is important for an accurate reading. A cuff that is too large will produce a reading that is lower than the correct blood pressure; a cuff that is too small yields a measurement that is higher. With your arm hanging at the side of your body, measure the circumference of your upper arm at the midpoint between shoulder and elbow. RECOMMENDED REPLACEMENT ARM SIZE CUFF SIZE CUFF MODEL# 5.1” - 7.9” (13-20cm) Small UA-279 7.5” - 12.2” (19-31c

Summary of the content on the page No. 7

TAKING YOUR BLOOD PRESSURE Tips for Blood Pressure Monitoring: Tips for Blood Pressure Monitoring: ☞ Relax for about 5 to 10 minutes before measurement. ☞ Relax for about 5 to 10 minutes before measurement. ☞ Remove constricting clothing and place cuff on bare arm. ☞ Remove constricting clothing and place cuff on bare arm. ☞ Unless your physician recommends otherwise, use left arm ☞ Unless your physician recommends otherwise, use left arm to measure pressure. to measure pressure. Now you are r

Summary of the content on the page No. 8

TAKING YOUR BLOOD PRESSURE ☞ IMPORTANT: Measure pressure at the same time each day. 4. Press the POWER button. 5. Watch for all display symbols to appear briefly, followed by a zero, indicating that monitor is ready for measurement. 6. Watch the display and squeeze the bulb quickly until cuff pressure reaches about 30 mmHg to 40 mmHg above expected systolic pressure. To help you determine the correct inflation level, the monitor is programmed to beep quickly three times at each of the four

Summary of the content on the page No. 9

TAKING YOUR BLOOD PRESSURE 7. Sit quietly during measurement. Pressure values are displayed at left, then right, along with ❤ symbol blinks and beeps with pulse beat. NOTE: If you wish to stop inflation at any time, press the exhaust valve to release air. 8. Wait for the long beep, indicating that the measurement is complete. Your systolic pressure will appear on the left and your diastolic pressure on the right of the display screen, alternating with pulse reading. 9. Press the exhaust val

Summary of the content on the page No. 10

TAKING YOUR BLOOD PRESSURE 10.Remove cuff and make a note of your blood pressure and pulse rate on the chart (see page 16), indicating date and time of measurement. We advise that you record the date and time after each measure- ment because an accurate blood pressure history relies not on single or sporadic readings but on a pattern over time. NOTE: If you wish to take your blood pressure again, relax and wait 5–10 minutes to enable the flow of blood in the arm to return to normal. There

Summary of the content on the page No. 11

CHECK/ADJUST EXHAUST VELOCITY Exhaust velocity is the rate at which the air pressure in the cuff deflates during the course of measurement. It is preset at the factory and generally does not need any further adjustment. NOTE: The exhaust rate of your monitor was preset and tested at the factory to ensure proper measurement. The rate set is dependent on cuff size, not arm size. If using a cuff other than the one shipped with the unit, you may need to adjust the exhaust velocity rate. To check t

Summary of the content on the page No. 12

CHECK/ADJUST EXHAUST VELOCITY 4. Watch the display screen. As pressure automatically decreases, diastolic numbers should decline in increments of 2 to 5 mmHg. If the exhaust velocity range is not within 2 to 5 mmHg, make the following adjustment with the unit turned off: 1. The adjustment screw is located on the exhaust valve attached to the inflator bulb. It is covered by a thin grey protection cap with a hole in the center. To remove and discard the cap (you do not need to replace it), inse

Summary of the content on the page No. 13

ABOUT BLOOD PRESSURE ❤ What Is Blood Pressure? What Is Blood Pressure? Blood pressure is the force exerted by blood against the Blood pressure is the force exerted by blood against the walls of walls of the arteries. Systolic pressure occurs when the heart the arteries. Systolic pressure occurs when the heart contracts; contracts; diastolic pressure occurs when the heart expands. diastolic pressure occurs when the heart expands. Blood pressure Blood pressure is measured in millimeters of merc

Summary of the content on the page No. 14

ABOUT BLOOD PRESSURE ❤ Assessing High Blood Pressure Assessing High Blood Pressure The following standards for assessing high blood pressure The following standards for assessing high blood pressure (without regard to age) have been established as a guideline. (without regard to age) have been established by the National Institutes of Health JNCVI. BP Classification Systolic (mmHg) Diastolic (mmHg) Category Systolic (mmHg) Diastolic (mmHg) Normal <120 and <80 Optimal <120 <80 Prehypertension 12

Summary of the content on the page No. 15

ABOUT BLOOD PRESSURE ❤ Why Measure Blood Pressure at Home? Why Measure Blood Pressure at Home? It is now well known that, for many individuals, blood pres- It is now well known that, for many individuals, blood sure readings taken in a doctor’s office or hospital setting pressure readings taken in a doctor’s office or hospital setting might be elevated as a result of apprehension and anxiety. might be elevated as a result of apprehension and anxiety. This response is commonly called “white coa

Summary of the content on the page No. 16

TM BLOOD PRESSURE RECORD Name: Age: Weight: DATE AM SYS/DIA PULSE PM SYS/DIA PULSE 1/14 9:30 132/98 P 63 P 69 6:30 128/87 EXAMPLE LifeSource Health Line (Toll-Free): 1-888-726-9966 16 ❤

Summary of the content on the page No. 17

IMPORTANT INFORMATION ✓ Please read this important information before using your monitor. ☞ Please remember that only a medical practitioner is qualified to interpret your blood pressure measurements. Use of this device should not replace regular medical examinations. ☞ Have your physician review your procedure for using this device. He or she will want to verify blood pressure measurements before prescribing or adjusting medications. ☞ Consult your physician if you have any doubt about your

Summary of the content on the page No. 18

SPECIFICATIONS SPECIFICATIONS ✓ Model . . . . . . . . . . . . . . . . . . .UA-702 Type . . . . . . . . . . . . . . . . . . . . .Oscillometric Display . . . . . . . . . . . . . . . . . .Digital, 10-mm character height Pressure/pulse displayed alternately Measurement range . . . . . . . . .Pressure: 20 mmHg to 280 mmHg Pulse: 40 pulses to 200 pulses/minute Accuracy . . . . . . . . . . . . . . . . .Pressure: +3 mmHg or 2%, whichever is greater Pulse: +5% Pressurization . . . . . . . . . . . .Manu

Summary of the content on the page No. 19

CONTACT INFORMATION Our products are designed and manufactured using the latest Our products are designed and manufactured using the latest scientific and technological methods, and offer accurate, easy to scientific and technological methods, and offer accurate, easy use, home monitoring and treatment options. The product to use, home monitoring and treatment options. Our full product line includes: line includes: Aneroid Blood Pressure Kits Aneroid Blood Pressure Kits Blood Pressure Cuffs Bl

Summary of the content on the page No. 20

CONTACT INFORMATION IMPORTANT! If You Need Assistance with the Set-Up or Operation We Can Help! Please call us FIRST before contacting your retailer at LifeSource Health Line 1-888-726-9966 - Toll Free 1-800-463-5414 - In Canada A specially trained representative will assist you A division of A&D Engineering, Inc. 1555 McCandless Drive Milpitas, CA 95035 www.LifeSourceOnline.com LifeSource is a trademark of A&D Medical. ©2003 A&D Medical. All rights reserved. Specifications subject to change


Alternative user manuals
# User manual Category Download
1 LifeSource UA-767T User manual Blood Pressure Monitor 56
2 LifeSource UB-328 User manual Blood Pressure Monitor 46
3 LifeSource UA-787 User manual Blood Pressure Monitor 72
4 LifeSource UA-767PAC User manual Blood Pressure Monitor 27
5 LifeSource Bilingual Instruction Guide UB-521 User manual Blood Pressure Monitor 219
6 LifeSource UA-100 User manual Blood Pressure Monitor 3
7 LifeSource UA-705 User manual Blood Pressure Monitor 79
8 LifeSource UA-704 User manual Blood Pressure Monitor 34
9 LifeSource UA-787EJ User manual Blood Pressure Monitor 6
10 LifeSource UA-767 User manual Blood Pressure Monitor 192
11 LifeSource UA-774 User manual Blood Pressure Monitor 10
12 LifeSource UA-767 Plus User manual Blood Pressure Monitor 349
13 LifeSource UA-631V User manual Blood Pressure Monitor 80
14 LifeSource UA-787 User manual Blood Pressure Monitor 188
15 LifeSource UA-851/V/VL User manual Blood Pressure Monitor 1
16 Philips 319 User manual Blood Pressure Monitor 0
17 Philips HF319 User manual Blood Pressure Monitor 9
18 Philips M3860A User manual Blood Pressure Monitor 17
19 Philips M3861A User manual Blood Pressure Monitor 4
20 Philips M5066A User manual Blood Pressure Monitor 51