  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual LifeSource UA-705 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual LifeSource UA-705 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
LifeSource UA-705 User manual - Online PDF
Advertisement
« Page 1 of 23 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual LifeSource UA-705 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to LifeSource UA-705. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

UA705 6/3/05 12:46 PM Page 1
ADVANCED MANUAL INFLATE
Blood Pressure Monitor
Trilingual Instruction Guide – MODEL UA-705
English • Français • Español

Summary of the content on the page No. 2

UA705 6/3/05 12:46 PM Page 3 IMPORTANT INFORMATION  Please read this important information before using your monitor. Please remember that only a medical practitioner is qualified to inter-  pret your blood pressure measurements. Use of this device should not replace regular medical examinations. Have your physician review your procedure for using this device. He  or she will want to verify blood pressure measurements before pre- scribing or adjusting medications. Consult your physician i

Summary of the content on the page No. 3

UA705 6/3/05 12:46 PM Page 4 Fast. Easy. Accurate. ® Congratulations on purchasing a state-of-the-art LifeSource blood pressure monitor—one of the most technologically advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pres- sure regimen. Physicians agree that daily self-monitoring of blood pressure is an important step individuals can take to maintain cardiovas- cular health and prevent the serious consequences associated

Summary of the content on the page No. 4

UA705 6/3/05 12:47 PM Page 5 TABLE OF CONTENTS WHAT DISPLAY SYMBOLS MEAN . . . . . . . . . . . . . . . . . . . E-2 MONITOR COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . E-3 HOW UA-705 WORKS . . . . . . . . . . . . . . . . . . . . . . . . . . . E-4 ? BEFORE YOU START . . . . . . . . . . . . . . . . . . . . . . . . . . . E-4 SELECTING THE CORRECT CUFF SIZE . . . . . . . . . . . . . . . E-5 TAKING YOUR BLOOD PRESSURE . . . . . . . . . . . . . E-6 — E-8 WHAT IS AN IRREGULAR HEARTBEAT

Summary of the content on the page No. 5

UA705 6/3/05 12:47 PM Page 6 WHAT DISPLAY SYMBOLS MEAN ? Display Condition/Cause Recommended Symbol Action The symbol shown while measure- Measurement is in progress, remain ment is in progress. It blinks while as still as possible. detecting the pulse. An irregular heartbeat or body move- Take measurement again and con- ment may have occurred. Refer to sult with your physician. page E-9 for more information on irregular heartbeats. Previous measurement stored in MEMORY. The battery power ind

Summary of the content on the page No. 6

UA705 6/3/05 12:47 PM Page 7 MONITOR COMPONENTS ? ARM CUFF PROPER FIT RANGE INDEX MARK AIR HOSE DISPLAY AIR SOCKET AIR CONNECTOR PLUG EXHAUST START BUTTON RUBBER BULB BATTERY COVER BATTERY COMPARTMENT AA BATTERY LifeSource Health Line (Toll-Free): 1-888-726-9966 E-3 ?

Summary of the content on the page No. 7

UA705 6/3/05 12:47 PM Page 8 HOW UA-705 WORKS ? ® LifeSource blood pressure monitors are easy to use, accurate and digitally display full measurement readouts. Our technology is based on the “oscillo- metric method” – a noninvasive blood pressure determination. The term “oscillation” refers to any measure of vibrations caused by the arterial pulse. Our monitor examines the pulsatile pressure generated by the arterial wall as it expands and contracts against the cuff with each heartbeat. The c

Summary of the content on the page No. 8

UA705 6/3/05 12:47 PM Page 9 SELECTING THE CORRECT CUFF SIZE Using the correct cuff size is important for an accurate reading. A cuff that is too large will produce a reading that is lower than the correct blood pressure; a cuff that is too small will produce a reading that is higher than the correct blood pressure. With your arm hanging at the side of your body, measure the circumference of your upper arm at the midpoint between the shoulder and elbow. RECOMMENDED REPLACEMENT ARMSIZE CUFF SI

Summary of the content on the page No. 9

UA705 6/3/05 12:47 PM Page 10 en TAKING YOUR BLOOD PRESSURE Tips for Blood Pressure Monitoring: Relax for about 5 minutes before measurement.  Do not smoke or ingest caffeine at least 30 minutes prior to  measurement. Remove constricting clothing and place cuff on bare arm.  Unless your physician recommends otherwise, use left arm to  measure pressure. Do not talk during measurement.  Do not cross legs and keep you feet flat on floor during measurement.  Now you are ready. Follow

Summary of the content on the page No. 10

UA705 6/3/05 12:47 PM Page 11 TAKING YOUR BLOOD PRESSURE 5. Press the START button. Your average blood pressure reading will appear with the number of measurements stored in memory (i.e. A25 = total of 25 measurements stored in memory) and a flashing symbol, indicating that monitor is ready for measurement. NOTE: If the symbol is displayed, the cuff has some air trapped in it. Press the exhaust valve button until the symbol is displayed. You may have to press on the cuff while h

Summary of the content on the page No. 11

UA705 6/3/05 12:47 PM Page 12 TAKING YOUR BLOOD PRESSURE 8. When the correct pressurization has been reached, the automatic exhaust mechanism will gradually reduce the pressure in the cuff. Sit quietly during measurement. The ❤ symbol will blink with your pulse beat. NOTE: Exhaust rate cannot be adjusted during measurement. If you wish to stop inflation at any time, press the exhaust valve to release the pres- sure in the cuff. 9. After you see the measurement results displayed on the scr

Summary of the content on the page No. 12

UA705 6/3/05 12:47 PM Page 13 WHAT IS AN IRREGULAR HEARTBEAT The UA-705 Blood Pressure Monitor provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. The Irregular Heartbeat symbol will appear in the display window in the event an Irregular Heartbeat has occurred during measurement. An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeat intervals during the blood pressure measurement. It is important

Summary of the content on the page No. 13

UA705 6/3/05 12:47 PM Page 14 ABOUT AVERAGE READING Le UA-705 fournit une lecture moyenne de la tension artérielle selon les mesures totales enregistrées dans la mémoire. Pendant la prise d'une mesure, la lecture moyenne de la ten- sion artérielle apparaîtra et le nombre de mesures enregistrées dans la mémoire clignotera plusieurs fois avant que le brassard commence à gonfler. La lecture moyenne apparaîtra briève- ment lors de la récupération des mesures de la mémoire. AVERAGE NUMBER OF MEAS

Summary of the content on the page No. 14

UA705 6/3/05 12:47 PM Page 15 ABOUT MEMORY The UA-705 automatically stores up to 30 blood pressure and pulse measure- ments in its memory. Measurements stored in memory are assigned an index number in the order of the newest to the oldest. The oldest reading displays as "n01". To retrieve readings, follow these simple steps: 1. When the display screen is blank, press and hold the START button. While holding down the START button, you will see the average reading displayed first. You will the

Summary of the content on the page No. 15

UA705 6/3/05 12:47 PM Page 16 ABOUT BLOOD PRESSURE What Is Blood Pressure? Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the heart contracts; diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of mercury (mmHg). What Affects Blood Pressure? Blood pressure is affected by many factors: age, weight, time of day, activity level, climate, altitude and season. Certain activities can significant

Summary of the content on the page No. 16

UA705 6/3/05 12:47 PM Page 17 ABOUT BLOOD PRESSURE Assessing High Blood Pressure for Adults The following standards for assessing high blood pressure (without regard to age or gender) have been established as a guideline. Please note that other risk factors (e.g. diabetes, obesity, smoking, etc.) need to be taken into con- sideration and may affect these figures. Consult with your physician for an accurate assessment. JNC7 Classification Table – for Adults within the U.S. BP Classification Sy

Summary of the content on the page No. 17

UA705 6/3/05 12:47 PM Page 18 ABOUT BLOOD PRESSURE What Is Hypertension? Hypertension (high blood pressure) is the diagnosis given when readings consistently rise above normal. It is well known that hypertension can lead to stroke, heart attack or other illness if left untreated. Referred to as a “silent killer” because it does not always produce symptoms that alert you to the problem, hypertension is treatable when diagnosed early. Can Hypertension Be Controlled? In many individuals, hyperte

Summary of the content on the page No. 18

UA705 6/3/05 12:47 PM Page 19 ABOUT BLOOD PRESSURE Answers to Why Your Readings Are Different Between Home and at the Doctor’s Office Why are my readings different between home and at a doctor’s office? Your blood pressure readings taken in a doctor’s office or hospital setting may be elevated as a result of apprehension and anxiety. This response is known as white coat hypertension. When I bring my monitor to a doctor’s office, why do I get a different measurement from my monitor to that ta

Summary of the content on the page No. 19

UA705 6/3/05 12:47 PM Page 20 ABOUT BLOOD PRESSURE Establishing Baseline Measurements The most important method to get an accurate blood pressure measurement is consistency. To get the most benefit out of your monitor, it is important to establish a “baseline measurement.” This helps build a foundation of meas- urements that you can use to compare against future readings. To build this baseline measurement, devote two weeks for consistent blood pressure moni- toring. This involves doing every

Summary of the content on the page No. 20

UA705 6/3/05 12:47 PM Page 21 TROUBLESHOOTING Problem Probable cause Corrective action Nothing appears in Battery is drained. Replace battery with new one. the display, after Alkaline battery pressing the START recommended. button. Battery terminals are not in Reinstall the battery with neg- the correct position. ative and positive terminals matching those indicated in the battery compartment. Battery voltage is too low. Replace battery with new The cuff does not Low battery symbol blinks. on


Alternative user manuals
# User manual Category Download
1 LifeSource UA-767T User manual Blood Pressure Monitor 56
2 LifeSource UB-328 User manual Blood Pressure Monitor 46
3 LifeSource UA-787 User manual Blood Pressure Monitor 72
4 LifeSource UA-767PAC User manual Blood Pressure Monitor 27
5 LifeSource Bilingual Instruction Guide UB-521 User manual Blood Pressure Monitor 219
6 LifeSource UA-100 User manual Blood Pressure Monitor 3
7 LifeSource UA-704 User manual Blood Pressure Monitor 34
8 LifeSource UA-787EJ User manual Blood Pressure Monitor 6
9 LifeSource UA-767 User manual Blood Pressure Monitor 192
10 LifeSource UA-774 User manual Blood Pressure Monitor 10
11 LifeSource UA-702 User manual Blood Pressure Monitor 182
12 LifeSource UA-767 Plus User manual Blood Pressure Monitor 349
13 LifeSource UA-631V User manual Blood Pressure Monitor 80
14 LifeSource UA-787 User manual Blood Pressure Monitor 188
15 LifeSource UA-851/V/VL User manual Blood Pressure Monitor 1
16 Philips 319 User manual Blood Pressure Monitor 0
17 Philips HF319 User manual Blood Pressure Monitor 9
18 Philips M3860A User manual Blood Pressure Monitor 17
19 Philips M3861A User manual Blood Pressure Monitor 4
20 Philips M5066A User manual Blood Pressure Monitor 51