Summary of the content on the page No. 1
Model #
OPERATING INSTRUCTIONS
MH500PT
AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions
in a safe place for future reference. Do not allow anyone who has not read these
instructions to assemble, light, adjust or operate this tool.
Propane Torch
Model #MH500PT
MR. HEATER INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 216-881-5500 04/03 Revision L1 #72615
Summary of the content on the page No. 2
Read and understand instructions before use! FOR YOUR SAFETY! Retain this information for future reference. If you smell gas: - Shut off gas to the device. - DO NOT try to light appliance. - Extinguish any open flame. - Check the device for leaks using soapy water. - DO NOT attempt to relight the device until all leaks are repaired and there is no gas smell. DO NOT use this device in areas where gasoline or other liquids having flammable vapors are stored or used. CAUTION: This device is inte
Summary of the content on the page No. 3
FMH500PT-Parts List 1 2 3 ITEM DESCRIPTION PART NO. 1 ........................ Handle Assembly ........... 72601 2 ........................ Hose Assembly .............. 72602 3 ........................Striker ............................ 72603 When ordering repair parts, always furnish the following information: 1) Model Number 2) Part Number 3) Part Description CAUTION: Use only genuine Mr. Heater replacement parts. Never substitute parts. Do not use modified parts. When ordering replacement pa
Summary of the content on the page No. 4
OPERATING CHARACTERISTICS Model BTU Operating Inlet Pressure Temperature Range Range o o MH500PT 500,000* -10 F to 100 F 17 psi to 170 psi * Tank size and tank temperature can directly affect BTU output Assembly Instructions: Un-assembled Assembled 1) Unpack all the components and inspect for any damage. If any damage is discovered contact the delivery service or Mr. Heater immediately. 2) Connect the hose assembly to the handle assembly and tighten counterclockwise. NOTE: This is a left-hande
Summary of the content on the page No. 5
Leak Test: 1)Close torch adjusting valve. 2) Slowly open the supply tank shut-off valve. 3) Test all connections for possible gas leaks using leak test solution. 4) If a leak occurs at: Torch-adjusting valve stem • - Tighten stem packing nut clockwise - Slowly open supply tank shut-off valve and retest connection. Repeat if necessary - If leak cannot be stopped by tightening the stem packing nut a new stem assembly (part #VS-1S) may be required. Contact Mr. Heater for the proper replacement par
Summary of the content on the page No. 6
CAUTION: DO NOT smoke around or expose supply tank(s) to open flame or sparks. Always use the striker provided. Never use a match or lighter to ignite torch. Use of device other than the striker may cause personal injury. DO NOT place hand or any body part in the path of the flame while lighting or operating torch. This can result in personal injury. Shut-Off Instructions: 1)Close torch adjusting valve. 2)Close supply tank shut-off valve. 3)Open the torch-adjusting valve briefly to release any r
Summary of the content on the page No. 7
CAUTION: DO NOT smoke around or expose supply tank(s) to open flames or sparks. Storage: Never store a torch that is still hot. When the torch is stored indoors, the connection between the LP gas tank(s) and the device must be disconnected and the tank(s) removed from the device and stored outdoors in accordance with Chapter 5 of the “Standard for the Storage and Handling of Liquefied Petroleum Gases” ANSI/NFPA 58. CAUTION: DO NOT smoke around or expose supply tank(s) to open flame or sparks.
Summary of the content on the page No. 8
Model # OPERATING INSTRUCTIONS AND OWNER’S MANUAL MH500PT WARNING: USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY. PARTS ORDERING INFORMATION: PURCHASING: Accessories may be purchased at any Mr. Heater local dealer or direct from the factory FOR INFORMATION REGARDING SERVICE Please call Toll-Free 800-251-0001 www.mrheater.com Our office