Fluke 8508A user manual

User manual for the device Fluke 8508A

Device: Fluke 8508A
Category: Wireless Office Headset
Manufacturer: Fluke
Size: 0.24 MB
Added : 9/4/2013
Number of pages: 13
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fluke 8508A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fluke 8508A.

For your convenience

If looking through the Fluke 8508A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fluke 8508A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fluke 8508A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fluke 8508A User manual - Online PDF
Advertisement
« Page 1 of 13 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fluke 8508A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fluke 8508A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1





Multimeter Selection Guide
Fluke 8508A & Agilent 3458/HFL


TECHNICAL INFORMATION



When comparing two products features and specification using sales information
it is often difficult to determine which product will meet the needs of your specific
application. This is mostly because each supplier will define specifications using
alternate methods. This Selection Guide will help you compare the specifications
and features of the Fluke 8508A Reference multimeter with the near

Summary of the content on the page No. 2

DC Voltage ±(ppm of setting + ppm of range), relative to calibration standards used. Calibration Interval 365 day, ±1°C of last TCAL Range 1281 HP3458/HFL 8508A 120.00000mV - 4 + 3 - 199.999999mV 6 + 0.5 - 2.7 + 0.5 1.20000000V - 3 + 0.3 - 1.99999999V 3 + 0.2 - 2.7 + 0.2 12.000000V - 3 + 0.05 - 19.9999999V 3 + 0.2 - 2.7 + 0.2 120.00000V - 5 + 0.3 - 199.999999V 6 + 0.1 - 4.0 + 0.2 1050.0000V 6 + 0.1 5 + 0.1 4.0 + 0.5

Summary of the content on the page No. 3

DC Current ±(ppm of setting + ppm of range), relative to calibration standards used. Calibration Interval 365 day, ±1°C of last TCAL Range 1281 HP3458/HFL 8508A 120.000nA - 30 + 400 - 1.200000µA - 20 + 40 - 12.000000µA - 20 + 10 - 120.00000µA - 20 + 8 - 199.99999µA 25 + 2 - 6.5 + 2.0 1.2000000mA - 20 + 5 - 1.9999999mA 25 + 2 - 6.5 + 2.0 12.000000mA - 20 + 5 - 19.999999mA 25 + 2 - 8.0 + 2.0 120.00000mA - 35 + 5 - 199.99999mA 50 + 5 - 33 + 4.0 1.0500000A - 110 + 10 - 1.9999999A 150 + 10 -

Summary of the content on the page No. 4

Resistance ±(ppm of setting + ppm of range), relative to calibration standards used. Calibration Interval 365 day, ±1°C of last TCAL Range 1281 HP3458/HFL 8508A 1.99999999 Ohm - - 10 + 2.0 12.00000 Ohm - 10 + 5 - 19.9999999 Ohm 12 + 1.0 - 7.0 + 0.7 120.00000 Ohm - 8 + 5 - 199.999999 Ohm 8 + 0.3 7.0 + 0.25 1.2000000 kOhm - 7.5 + 0.5 - 1.99999999 kOhm 6 + 0.3 - 7.0 + 0.25 12.000000 kOhm - 7.5 + 0.5 - 19.9999999 kOhm 6 + 0.3 - 7.0 + 0.25 120.00000 kOhm - 7.5 + 0.5 - 199.999999 kOhm 6 + 0.3 - 7.0

Summary of the content on the page No. 5

AC Current ±(ppm of setting + ppm of range), relative to calibration standards used. Calibration Interval 365 day, ±1°C of last TCAL Range Frequency 1281 HP3458/HFL 8508A 120.0000µA 10Hz - 20Hz - 4000 + 200 - 20Hz - 45Hz - 1500 + 200 - 45Hz - 100Hz - 600 + 200 - 100Hz - 5kHz - 600 + 200 - 199.9999µA 1Hz - 10Hz - - 250 + 100 10Hz - 5kHz 200 + 200 - - 10Hz - 10kHz - - 250 + 100 10kHz - 30kHz - - 600 + 100 30kHz - 100kHz - - 4000 + 100 1.2000000mA 10Hz - 20Hz - 4000 + 200 - 20Hz - 45Hz - 1500 + 2

Summary of the content on the page No. 6

AC Voltage ±(ppm of setting + ppm of range), relative to calibration standards used. Calibration Interval 365 day, ±1°C of last TCAL Range Frequency 1281 HP3458/HFL 8508A 12.00000mV 1Hz - 40Hz - 300 + 300 - 40Hz - 1kHz - 200 + 110 - 1kHz - 20kHz - 300 + 110 - 20kHz - 50kHz - 1000 + 110 - 50kHz - 100kHz - 5000 + 110 - 100kHz - 300kHz - 40000 + 200 - 120.0000mV 1Hz - 40Hz - 70 + 40 - 40Hz - 1kHz - 70 + 20 - 1kHz - 20kHz - 140 + 20 - 20kHz - 50kHz - 300 + 20 - 50kHz - 100kHz - 800 + 20 - 100kHz -

Summary of the content on the page No. 7

AC Voltage ±(ppm of setting + ppm of range), relative to calibration standards used. Calibration Interval 365 day, ±1°C of last TCAL Range Frequency 1281 HP3458/HFL 8508A 19.99999V 1Hz - 10Hz - - 100 + 60 10Hz - 40Hz - - 100 + 10 40Hz - 100Hz 80 + 10 - 80 + 10 100Hz - 2kHz 60 + 10 - 60 + 10 2kHz - 10kHz 80 + 10 - 80 + 10 10kHz - 30kHz 200 + 20 - 200 + 20 30kHz - 100kHz 500 + 100 - 500 + 100 100kHz - 300kHz 3000 + 1000 - 3000 + 1000 300kHz - 1MHz 10000 + 10000 - 10000 + 10000 120.0000V 1Hz -

Summary of the content on the page No. 8

Fluke 8508A 3458/HFL 8508A vs 3458/HFL Functional & Versatility Comments Parameters 8508A maintains >10Gohm input impedance to 20Vdc. This compares with 12V on 120mV, 1.2V, 12V, 120V, Full Scale (dc & ac Voltage) 200mV, 2V, 20V, 200V, 1050Vrms 3458/HFL. The 8508A 1050Vrms 1050Vdc (ac = 700Vrms) measurement is often used to calibrate calibrators at 1000 Vrms output. 3458A/HFL has lower current ranges with a sensitivity of 1pA compared with 10pA on the 8508A – th

Summary of the content on the page No. 9

8508A vs 3458/HFL Functional & Versatility Comments Parameters High Resistance Reduces errors when performing high Test Voltage or Full Scale Test Voltage or Full Scale resistance measurement (feature available Measurement (compliance stimulus = 200V stimulus @ 1.2GΩ = 5V voltage) 8508A - 20MΩ to 20GΩ range only) Current reversal reduces errors caused by Tru-Ohms or Offset thermal emfs as does switched current but Current Reversal Switched Current Compensated Resistance revers

Summary of the content on the page No. 10

4-wire sense measurement support Selectable 2 and 4-wire ACV & DCV 4 wire input. Unavailable improved accuracy when calibrating measurement. calibrators with 4 wire sense output. IEEE control of GUARD terminal helps fully Remote switched GUARD IEEE controlled Manual Switch automate calibration without need for Terminal manual switching. High Speed - 150 readings/sec @ High Speed - 100,000 High read rates are useful for some ATE Read rate 5.5 digit resolution reading/sec @

Summary of the content on the page No. 11

8508A vs 3458/HFL Comments Ease of Use Parameters Rear input switched remotely The 3458/HFL must be switched manually Yes No using IEEE 488 commands using a front panel button. Instrument simultaneously Requires further commands or key presses displays Frequency as well as Yes Selectable to determine frequency. the AC voltage & current. 8508A can accept and compare dc to dc, ac to ac, dc to ac, Resistance to Resistance & Temperature to Temperature. Auto-ranging Two channel Ra

Summary of the content on the page No. 12

8508A Options and Accessories: Model Description 8508A 8.5 digit Reference Multimeter 8508A/01 8.5 digit Reference Multimeter with Rear Input Ratio measurement Accessories 8508A-SPRT Standard Platinum Resistance Thermometer 8508A-PRT Platinum Resistance Thermometer 8508A-LEAD Comprehensive Measurement Lead Kit Y8508 Rack Mount Kit Y8508S Rack Mount Kit Slides 8508A-7000K Calibration kit comprising 1GOhm Standard and connecting leads. 1883673 UKAS Accredited Cer

Summary of the content on the page No. 13

Notes:


Alternative user manuals
# User manual Category Download
1 Fluke 3458/HFL User manual Wireless Office Headset 1
2 Fluke 1920A User manual Wireless Office Headset 2
3 AeroComm TRANSCEIVER ZB2430 User manual Wireless Office Headset 0
4 Agilent Technologies Option 100 User manual Wireless Office Headset 0
5 Agilent Technologies 4338A User manual Wireless Office Headset 1
6 Agilent Technologies E2625A User manual Wireless Office Headset 1
7 Agilent Technologies 5071A User manual Wireless Office Headset 5
8 Aiphone JA-2SD User manual Wireless Office Headset 0
9 Aiphone B User manual Wireless Office Headset 0
10 Advantek Networks AWN-USB-54S User manual Wireless Office Headset 23
11 Sony XBA-BT75 User manual Wireless Office Headset 15
12 Aiphone nch-2 User manual Wireless Office Headset 0
13 Aiphone TD1-H User manual Wireless Office Headset 0
14 Black Box 26721 User manual Wireless Office Headset 1
15 Bell RT27 User manual Wireless Office Headset 0