Miller Electric Intellifire 250 user manual

User manual for the device Miller Electric Intellifire 250

Device: Miller Electric Intellifire 250
Category: Welding System
Manufacturer: Miller Electric
Size: 0.94 MB
Added : 3/13/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Miller Electric Intellifire 250. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Miller Electric Intellifire 250.

For your convenience

If looking through the Miller Electric Intellifire 250 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Miller Electric Intellifire 250 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Miller Electric Intellifire 250 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Miller Electric Intellifire 250 User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Miller Electric Intellifire 250 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Miller Electric Intellifire 250. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OM-184 227K
2006 −05
Processes
Induction Heating
Description
Induction Heating Power Source
Intellifire 250
File: Induction Heating
Visit our website at
www.MillerWelds.com

Summary of the content on the page No. 2

From Miller to You Thank you and congratulations on choosing Miller. Now you can get the job done and get it done right. We know you don’t have time to do it any other way. That’s why when Niels Miller first started building arc welders in 1929, he made sure his products offered long-lasting value and superior quality. Like you, his customers couldn’t afford anything less. Miller products had to be more than the best they could be. They had to be the best you could buy. Today, the people that bu

Summary of the content on the page No. 3

TABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-2. Induction Heating Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-3. Additional Symbols for Installation, Opera

Summary of the content on the page No. 4

Summary of the content on the page No. 5

SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING  Warning: Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage safety_ihom 5/05 Means Warning! Watch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.  Marks a special safety message. This group of symbols means Warning! Watch Out! possible ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.  Means “Note”; not safety related. Consult symbols

Summary of the content on the page No. 6

FIRE OR EXPLOSION hazard. INDUCTION HEATING can cause burns.  Do not overheat parts and adhesive.  Hot parts and equipment can injure.  Watch for fire; keep extinguisher nearby.  Do not touch or handle induction head/coil during operation.  Keep flammables away from work area.  Do not touch hot parts bare-handed.  Do not locate unit on, over, or near combustible surfaces.  Allow cooling period before handling parts or equipment.  Do not install unit near flammables.  Keep metal jewelry

Summary of the content on the page No. 7

1-6. EMF Information Considerations About Induction Heating And The Effects Of Low Fre- us to draw definite conclusions about questions of possible risk or to of- quency Electric And Magnetic Fields fer clear science-based advice on strategies to minimize or avoid potential risks.” The following is a quotation from the General Conclusions Section of the U.S. Congress, Office of Technology Assessment, Biological Effects of To reduce magnetic fields in the workplace, use the following proce- Power

Summary of the content on the page No. 8

SECTION 2 − MESURES DE SECURITE POUR LE CHAUFFAGE PAR INDUCTION ihom_fre 8/03 LE CHAUFFAGE PAR INDUCTION peut être dangereux. AVERTISSEMENT PRENDRE LES MESURES NECESSAIRES POUR EVITER LES RISQUES DE BLESSURES GRAVES, VOIRE MORTELLES. TENIR LES ENFANTS A DISTANCE. LES PORTEURS D’UN STIMULATEUR CARDIAQUE DOIVENT PREALABLEMENT CONSULTER LEUR MEDECIN. Pendant les opérations de chauffage, comme dans la plupart des activités, l’opérateur s’expose à certains dangers. Le chauffage n’est pas dangereux à

Summary of the content on the page No. 9

5. Travailler dans un espace fermé seulement s’il est bien ventilé ou DES FUMEES ET DES GAZ peuvent en portant un respirateur. Demander toujours à un surveillant être dangereux pour votre santé. dûment formé de se tenir à proximité. Des fumées et des gaz Le chauffage à induction génère des fumées et des provenant du chauffage peuvent déplacer l’air, abaisser le niveau gaz. Leur inhalation peut être dangereuse pour votre d’oxygène, et provoquer des lésions ou des accidents mortels. santé. S’assur

Summary of the content on the page No. 10

2-2. Informations concernant les champs électro-magnétiques (Information EMF) Considérations relatives au chauffage à induction et aux effets des proposer des recommandations scientifiques claires pour des champs électriques et magnétiques basse fréquence. stratégies à suivre en vue de minimiser ou de prévenir des risques potentiels.” Le texte suivant est extrait des conclusions générales Département du Congrès U.S., Office of Technology Assessment, Effets Pour réduire les champs magnétiques sur

Summary of the content on the page No. 11

SECTION 3 − INSTALLATION 3-1. Specifications Amperes Input at Required Rated Load Output 50 Output Reflective Rated Output or 60 Hz, Three-Phase Overall Dimensions Weight Frequency Frequency Inductance Inductance 460 V KVA KW Length: 31 in 25 kW At (787 mm) 100% Duty 39 Width: 16 in 165 lb 10 To 50 kHz Cycle − Max 2.5 To 50 μh 30.8 27.19 0.29* (406 mm) (75 kg) 750 A (RMS), Height: 27 in 700 V (RMS) (686 mm) *While idling WARNING HIGH-FREQUENCY RADIATION can interfere with radio navigation, safet

Summary of the content on the page No. 12

3-3. Remote 14 Receptacle RC14 Information and Connections 1 Front Panel 2 Plug 1 3 Threaded Collar 4 Keyway 5 Remote 14 Receptacle RC14 (See Section 3-4) To connect to receptacle, align key- way, insert plug, and tighten threaded collar. 4 AJ 5 K I B L NH C M D G F E 3 2 sb7.1* 3/93 - Ref. S-0004-A / Ref. S-0750 / Ref. ST-801 826-C 3-4. Remote 14 Socket Information Socket Socket Information +24 volts dc. A Remote Contactor Remote Contactor Contact closure to A completes 24 volts dc contactor co

Summary of the content on the page No. 13

3-5. Connecting 3-Phase Input Power For Models With Customer Supplied Cord  Installation must meet all National and Local Codes − have only quali- fied persons make this installation.  Disconnect and lockout/tagout in- put power before connecting input conductors from unit. 3  Make input power connections to the welding power source first. = GND/PE Earth Ground  Always connect green or green/ 9 yellow conductor to supply grounding terminal first, and never to a line terminal. 8 See rating

Summary of the content on the page No. 14

3-6. Electrical Service Guide 60 Hz Three Phase Input Voltage 460 Input Amperes At Rated Output 39 1 Max Recommended Standard Fuse Rating In Amperes 2 Time-Delay 45 3 Normal Operating 60 4 Min Input Conductor Size In AWG 8 287 Max Recommended Input Conductor Length In Feet (Meters) (87) 4 Min Grounding Conductor Size In AWG 10 Reference: 2005 National Electrical Code (NEC) (including article 630) 1 Consult factory for circuit breaker applications. 2 “Time-Delay” fuses are UL class “RK5” . 3 “No

Summary of the content on the page No. 15

SECTION 5 − MAINTENANCE & TROUBLESHOOTING 5-1. Routine Maintenance  Disconnect power  Maintain more often before maintaining. during severe conditions. 3 Months Clean and tighten Repair or replace output connections. cracked cables and cords. 6 Months Replace damaged or Blow out or vacuum unreadable labels. inside. 5-2. Overheating Thermostats TP1, TP2, and TP3 protect the unit from damage due to overheating. If one or more of the heat sinks get too hot, TP1, TP2, and/or TP3 opens and output

Summary of the content on the page No. 16

5-5. Measuring Tuning Capacitor Voltage  Significant AC voltage can remain on Turn Off power source and capacitors after unit is Off. Always disconnect input power. check ALL capacitors as shown to be Remove wrapper. sure they have discharged before 1 Tuning Capacitor C1 working on unit. 2 Tuning Capacitor C2 3 Tuning Capacitor C3 4 Voltmeter 4 Check tuning capacitors. Measure the ac voltage across the terminals on capacitors every 30 seconds until voltage is near 0 (zero) volts. Proceed with j

Summary of the content on the page No. 17

5-6. Ground Fault Protection Ground fault protection circuitry automatically shuts down the power source output if a potentially hazardous condition exists at the heating device connected to the 1 power source (e.g. insulation has broken down on a heating blanket causing the conductor to come into contact with the workpiece or a heating coil touches the workpiece causing a short in the output circuit). The supplied ground lead must be connected between the workpiece and power source to provide p

Summary of the content on the page No. 18

5-7. Measuring Input Capacitor Voltage Turn Off power source and  Significant DC voltage can remain on disconnect input power. capacitors after unit is Off. Always check ALL capacitors as shown to be Remove wrapper. sure they have discharged before 1 Input Capacitor C2 working on unit. 2 Input Capacitor C1 3 Input Capacitor C4 4 Input Capacitor C3 5 Voltmeter Check input capacitors. Measure the dc voltage across the positive (+) and negative ( −) terminals every 30 seconds until 12 3 4 voltage

Summary of the content on the page No. 19

5-8. Diagnostic LED’s 1 Diagnostic LED’s 1 Use diagnostic LED’s to determine operating condition of power source. 2 Current Source Limit: 110 A Fault: 115 A 3 Over Frequency Limit: 50 kHz Fault: 55 kHz 4 Under Frequency Limit: 10 kHz Fault: 5 kHz 5 Current Reactive Limit: 700 A 6 Tank Voltage Limit: 670 V Fault: 1100 V Peak 7 Line Voltage Fault: ±20 % 8 Contactor Lights when contactor is energized. 9 Over Temp Lights when contactor is energized and over temperature condition is FAULT LIMIT prese

Summary of the content on the page No. 20

5-9. Troubleshooting Trouble Remedy No heat output. Replace building line fuse or reset circuit breaker. Secure head/coil connecting plate to power source connecting block (see Section 3-2). Check and replace Power switch if necessary. Connect power source to proper input voltage or check for low line voltage. No heat output; fan motor continues to run. Safety interlock switch open. Reinstall wrapper (see Section 5-4). Thermostat(s) TP1, TP2, and/or TP3 open (overheating). Allow fan to run; the


Alternative user manuals
# User manual Category Download
1 Miller Electric 152 User manual Welding System 51
2 Miller Electric 251 NT User manual Welding System 39
3 Miller Electric 3000-4AH User manual Welding System 3
4 Miller Electric 250 DX User manual Welding System 193
5 Miller Electric 185 DX User manual Welding System 49
6 Miller Electric 175 User manual Welding System 7
7 Miller Electric 350MPa User manual Welding System 5
8 Miller Electric 185 User manual Welding System 8
9 Miller Electric 3000 User manual Welding System 7
10 Miller Electric 400P, 500 X User manual Welding System 38
11 Miller Electric 301 G User manual Welding System 4
12 Miller Electric 280 NT User manual Welding System 6
13 Miller Electric 350 LX User manual Welding System 84
14 Miller Electric 301 G, DC User manual Welding System 7
15 Miller Electric 750MPa User manual Welding System 2
16 Sony 6 User manual Welding System 0
17 ADTRAN NT1 T400 User manual Welding System 1
18 AEG 2000 User manual Welding System 2
19 AEG PV 2000 User manual Welding System 8
20 Agilent Technologies AC Power Solutions 6814B User manual Welding System 8