Lincoln Electric RANGER IM819-B user manual

User manual for the device Lincoln Electric RANGER IM819-B

Device: Lincoln Electric RANGER IM819-B
Category: Welding System
Manufacturer: Lincoln Electric
Size: 0.54 MB
Added : 5/23/2014
Number of pages: 37
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Lincoln Electric RANGER IM819-B. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Lincoln Electric RANGER IM819-B.

For your convenience

If looking through the Lincoln Electric RANGER IM819-B user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Lincoln Electric RANGER IM819-B on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Lincoln Electric RANGER IM819-B to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Lincoln Electric RANGER IM819-B User manual - Online PDF
Advertisement
« Page 1 of 37 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Lincoln Electric RANGER IM819-B but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Lincoln Electric RANGER IM819-B. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

IM819-B

September, 2006
RANGER 10,000
For Machines with Code Number 11041, 11095, 11151, 11253
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thought-
ful operation on your part. DO
NOT INSTALL, OPERATE OR
REPAIR THIS EQUIPMENT
WITHOUT READING THIS
MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED
THROUGHOUT. And, most
importantly, think before you act
and be caref

Summary of the content on the page No. 2

i i SAFETY WARNING CALIFORNIA PROPOSITION 65 WARNINGS Diesel engine exhaust and some of its constituents The engine exhaust from this product contains are known to the State of California to cause can- chemicals known to the State of California to cause cer, birth defects, and other reproductive harm. cancer, birth defects, or other reproductive harm. The Above For Diesel Engines The Above For Gasoline Engines ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY

Summary of the content on the page No. 3

ii ii SAFETY ELECTRIC SHOCK can ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover kill. plates to protect your eyes from sparks and 3.a. The electrode and work (or ground) circuits the rays of the arc when welding or observing are electrically “hot” when the welder is on. open arc welding. Headshield and filter lens Do not touch these “hot” parts with your bare should conform to ANSI Z87. I standards. skin or wet clothing. Wear dry, hole-free gloves to insulate hands. 4.b. Us

Summary of the content on the page No. 4

iii iii SAFETY WELDING SPARKS can CYLINDER may explode cause fire or explosion. if damaged. 6.a. Remove fire hazards from the welding area. 7.a.Use only compressed gas cylinders If this is not possible, cover them to prevent containing the correct shielding gas for the the welding sparks from starting a fire. process used and properly operating Remember that welding sparks and hot regulators designed for the gas and materials from welding can easily go through small cracks pressure used. All hos

Summary of the content on the page No. 5

iv iv SAFETY zones où l’on pique le laitier. PRÉCAUTIONS DE SÛRETÉ 6. Eloigner les matériaux inflammables ou les recouvrir afin de Pour votre propre protection lire et observer toutes les instructions prévenir tout risque d’incendie dû aux étincelles. et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- 7. Quand on ne soude pas, poser la pince à une endroit isolé de antes: la masse. Un court-circuit accidental peut provo

Summary of the content on the page No. 6

v v for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product Thank You ••• as much pride as we have in bringing this product to you! Please Examine Carton and Equipment For Damage Immediately When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims for material damaged in shipment must be made by the purchaser against the transportation company at the time the shipment

Summary of the content on the page No. 7

vi vi TABLE OF CONTENTS Page Installation.......................................................................................................................Section A Technical Specifications.......................................................................................................A-1 Safety Precautions ........................................................................................................A-2 Machine Grounding.......................................................

Summary of the content on the page No. 8

A-1 A-1 INSTALLATION TECHNICAL SPECIFICATIONS - Ranger 10,000 (K1419-4 ), (K2160-3 ) and (K2468-1) INPUT - GASOLINE ENGINE Description Operating Displacement Capacities Make/Model Horsepower Starting Speed (RPM) cu. in. System (cu.cm.) 38(624) Fuel: (K1419-4) 20 HP @ Kohler 9 Gal (34 L) Kohler 2 cylinder 3600 RPM Lubricating Oil: CH20S 12VDC 4 Cycle Kohler 2.0 Qts. (1.9 L) Battery Air-Cooled High Idle 3700 Electric Start Gasoline Group 58 Engine. 37.5 (614) Fuel: Battery Aluminum Alloy 20 H

Summary of the content on the page No. 9

A-2 A-2 INSTALLATION When this welder is mounted on a truck or trailer, it’s SAFETY PRECAUTIONS frame must be electrically bonded to the metal frame of the vehicle. Use a #8 or larger copper wire connect- WARNING ed between the machine grounding stud and the Do not attempt to use this equipment until you frame of the vehicle. have thoroughly read the engine manufacturer’s Where this engine driven welder is connected to manual supplied with your welder. It includes premises wiring such as that

Summary of the content on the page No. 10

A-3 A-3 INSTALLATION 3. Proper placement of the equipment on the trailer to FUEL insure stability side to side and front to back when being moved and when standing by itself while being operated or serviced. Fill the fuel tank with clean, fresh, lead-free gasoline. Observe fuel gauge while filling to prevent overfilling. 4. Typical conditions of use, i.e., travel speed; rough- ness of surface on which the trailer will be operated; environmental conditions. WARNING (1) • Damage to the fuel

Summary of the content on the page No. 11

A-4 A-4 INSTALLATION WELDING OUTPUT CABLES ADDITIONAL SAFETY PRECAUTIONS WARNING With the engine off, connect the electrode and work cables to the studs provided. These connections should be checked periodically and tightened if neces- • Lift only with equipment of sary. Loose connections will result in overheating of adequate lifting capacity. the output studs. • Be sure machine is stable when lifting. When welding at a considerable distance from the • Do not lift this machine using welder,

Summary of the content on the page No. 12

A-5 A-5 INSTALLATION d. Position the “RANGE” switch to the “WIRE FEED” LOCATION / VENTILATION position. The welder should be located to provide an unrestrict- ed flow of clean, cool air to the cooling air inlets and to e. Attach the single lead from the LN-25 control box avoid heated air coming out of the welder recirculating to the work using the spring clip on the end of the back to the cooling air inlet. Also, locate the welder so lead - it carries no welding current. that engine exhaust

Summary of the content on the page No. 13

A-6 A-6 INSTALLATION GND AUXILIARY POWER The RANGER 10,000 can provide up to 9,000 watts of 120/240 volts AC, single phase 60Hz power for con- tinuous use, and up to 10,000 watts of 120/240 volts AC, single phase 60Hz power peak use. The front of the machine includes three receptacles for connecting the AC power plugs; one 50 amp 120/240 volt NEMA 120 V 14-50R receptacle and two 20 amp 120 volt NEMA 5- 20R receptacles. Output voltage is within +/-10% at all 240 V loads up to rated capacity. 1

Summary of the content on the page No. 14

A-7 A-7 INSTALLATION TABLE lll ELECTRICAL DEVICE USE WITH THE RANGER 10,000. Type Common Electrical Devices Possible Concerns Resistive Heaters, toasters, incandescent NONE light bulbs, electric range, hot pan, skillet, coffee maker. Capacitive TV sets, radios, microwaves, Voltage spikes or high voltage appliances with electrical control. regulation can cause the capac- itative elements to fail. Surge protection, transient protection, and additional loading is recom- mended for 100% fail-sa

Summary of the content on the page No. 15

A-8 A-8 INSTALLATION 1. Install a double pole, double throw switch between AUXILIARY POWER WHILE WELDING the power company meter and the premises disconnect. Simultaneous welding and power loads are permitted by following Table I. The permissible currents shown Switch rating must be the same or greater than assume that current is being drawn from either the the customer’s premises disconnect and service 120V or 240V supply (not both at the same time). overcurrent protection. Also, the “Output

Summary of the content on the page No. 16

A-9 A-9 INSTALLATION Figure 1 CONNECTION OF RANGER 10,000 TO PREMISES WIRING 240 VOLT GROUNDED CONDUCTOR POWER 240 Volt 120 VOLT 60 Hz. COMPANY 3-Wire 120 VOLT Service METER NEUTRAL BUS N LOAD DOUBLE POLE DOUBLE THROW SWITCH RATING TO BE THE SAME AS OR GREATER THAN PREMISES SERVICE OVERCURRENT PROTECTION. PREMISES DISCONNECT AND SERVICE GROUND OVERCURRENT 40 AMP PROTECTION 240 VOLT DOUBLE POLE 50 AMP, 120/240 CIRCUIT VOLT PLUG 240 VOLT BREAKER NEMA TYPE 14-50 GND N 50 AMP, 120/240 VOLT NOTE:

Summary of the content on the page No. 17

B-1 B-1 OPERATION SAFETY PRECAUTIONS WELDER CONTROLS - FUNCTION AND Do not attempt to use this equipment until you OPERATION have thoroughly read the engine manufacturer’s manual supplied with your welder. It includes ENGINE SWITCH important safety precautions, detailed engine The engine switch is used to Start the Engine, Select starting, operating and maintenance instructions, High Idle or Auto Idle while the engine is running, and and parts lists. stop the Engine. ---------------------------

Summary of the content on the page No. 18

B-2 B-2 OPERATION “ RANGE” SWITCH The “Range” switch is used to select one of three amperage ranges with generous overlap for Stick/TIG welding, or one Wire Feed welding range. Process Range Setting Current Range STICK/TIG 90 Max. 40 to 90 Amps (constant current) 145 Max. 70 to 145 Amps (3 range settings) 210DC/225AC Max. 120 to 210 (DC) 225(AC) WIRE FEED (constant voltage) 15 to 25V Up to 200 Amps (one range setting) CAUTION Never change the “RANGE” Switch setting while welding.

Summary of the content on the page No. 19

B-3 B-3 OPERATION STARTING/SHUTDOWN INSTRUCTIONS STOPPING THE ENGINE STARTING THE ENGINE Remove all welding and auxiliary power loads and allow engine to run at low idle speed for a few minutes WARNING to cool the engine. • Do not touch electrically live parts Stop the engine by placing the Engine switch in the of electrode with skin or wet “OFF” position. clothing. A fuel shut off valve is not required on the Ranger 10,000 because the fuel tank is mounted below the engine. • Keep flammable mate

Summary of the content on the page No. 20

B-4 B-4 OPERATION SETTINGS FOR 1% THORIATED TUNGSTEN WELDING PROCESS For any electrodes the procedures should be kept TUNGSTEN RANGESWITCH APPROXIMATE DIAMETER (in.) SETTINGS CURRENT RANGE within the rating of the machine. For electrode infor- mation see the appropriate Lincoln publication. 1/8 90, 145, or 210 80 - 225 Amps 3/32 90 or 145 50 - 180


Alternative user manuals
# User manual Category Download
1 Lincoln Electric AIR VANTAGE 500 CUMMINS IM826-A User manual Welding System 35
2 Lincoln Electric AUTO-DARKENING HELMET IM10001 User manual Welding System 6
3 Lincoln Electric AIR VANTAGE IM10041 User manual Welding System 3
4 Lincoln Electric CLASSIC III 10033 User manual Welding System 1
5 Lincoln Electric 455M/STT User manual Welding System 29
6 Lincoln Electric 404D-22 User manual Welding System 0
7 Lincoln Electric BULLDOG TM 140 IM10005 User manual Welding System 1
8 Lincoln Electric CLASSIC 300D KUBOTA IM843-C User manual Welding System 6
9 Lincoln Electric CLASSIC III 10072 User manual Welding System 2
10 Lincoln Electric AC/DC1000 User manual Welding System 24
11 Lincoln Electric CLASSIC III 10156 User manual Welding System 1
12 Lincoln Electric CLASSIC III 10061 User manual Welding System 0
13 Lincoln Electric COMMANDER 300 IM601-A User manual Welding System 40
14 Lincoln Electric CLASSIC III SVM 137-A User manual Welding System 0
15 Lincoln Electric Excalibur 11018M MR User manual Welding System 8
16 Sony 6 User manual Welding System 0
17 ADTRAN NT1 T400 User manual Welding System 1
18 AEG 2000 User manual Welding System 2
19 AEG PV 2000 User manual Welding System 8
20 Agilent Technologies AC Power Solutions 6814B User manual Welding System 8