Hitachi L100 user manual

User manual for the device Hitachi L100

Device: Hitachi L100
Category: Welding System
Manufacturer: Hitachi
Size: 5.04 MB
Added : 4/15/2013
Number of pages: 192
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Hitachi L100. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Hitachi L100.

For your convenience

If looking through the Hitachi L100 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Hitachi L100 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Hitachi L100 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Hitachi L100 User manual - Online PDF
Advertisement
« Page 1 of 192 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Hitachi L100 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Hitachi L100. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Cover
HITACHI
L100 Series Inverter
Instruction Manual
• Single-phase Input 200V Class
 Three-phase Input 200V Class
 Three-phase Input 400V Class
Manual Number: NB576XC
After reading this manual,
keep it handy for future reference.
Hitachi Industrial Equipment Systems Co., Ltd.

Summary of the content on the page No. 2

i L100 Inverter Safety Messages For the best results with the L100 Series inverter, carefully read this manual and all of the warning labels attached to the inverter before installing and operating it, and follow the instructions exactly. Keep this manual handy for quick reference. Definitions and Symbols A safety instruction (message) includes a “Safety Alert Symbol” and a signal word or phrase such as WARNING or CAUTION. Each signal word has the following meaning: HIGH VOLTAGE: This symbol

Summary of the content on the page No. 3

ii General Precautions - Read These First! WARNING: This equipment should be installed, adjusted, and serviced by qualified electrical maintenance personnel familiar with the construction and operation of the equipment and the hazards involved. Failure to observe this precaution could result in bodily injury. WARNING: The user is responsible for ensuring that all driven machinery, drive train mechanism not supplied by Hitachi Industrial Equipment Systems Co., Ltd., and process line material

Summary of the content on the page No. 4

iii L100 Inverter WARNING: Rotating shafts and above-ground electrical potentials can be hazardous. Therefore, it is strongly recommended that all electrical work conform to the National Electrical Codes and local regulations. Installation, alignment and maintenance should be performed only by qualified personnel. Factory-recommended test procedures included in the instruction manual should be followed. Always disconnect electrical power before working on the unit. CAUTION: a) Class I motor

Summary of the content on the page No. 5

iv Index to Warnings and Cautions in This Manual Installation - Cautions for Mounting Procedures CAUTION: The inverter is shipped with a plastic cover over the top vent ....... 2–6 grill. REMOVE this cover after the installation is complete. Operation with this cover in place will not allow proper cooling, and damage to the inverter may result. CAUTION: Be sure to install the unit on flame-resistant material such as ....... 2–7 a steel plate. Otherwise, there is the danger of fire. CAUTION: Be

Summary of the content on the page No. 6

v L100 Inverter WARNING: “Suitable for use on a circuit capable of delivering not more .... 2–13 than 5,000 rms symmetrical amperes, 480 V maximum.” For models with suffix H. HIGH VOLTAGE: Be sure to ground the unit. Otherwise, there is a .... 2–13 danger of electric shock and/or fire. HIGH VOLTAGE: Wiring work shall be carried out only by qualified .... 2–13 personnel. Otherwise, there is a danger of electric shock and/or fire. HIGH VOLTAGE: Implement wiring after checking that the power ....

Summary of the content on the page No. 7

vi CAUTION: Remarks for using ground fault interrupter breakers in the ..... 2–17 main power supply: Adjustable frequency inverters with CE-filters (RFI- filter) and shielded (screened) motor cables have a higher leakage current toward Earth GND. Especially at the moment of switching ON this can cause an inadvertent trip of ground fault interrupters. Because of the rectifier on the input side of the inverter there is the possibility to stall the switch-off function through small amounts of D

Summary of the content on the page No. 8

vii L100 Inverter Warnings for Configuring Drive Parameters WARNING: When parameter B_12, level of electronic thermal setting, is .... 3–24 set to device FLA rating (Full Load Ampere nameplate rating), the device provides solid state motor overload protection at 115% of device FLA or equivalent. Parameter B_12, level of electronic thermal setting, is a variable parameter. WARNING: Use a disconnect switch or breaker to ensure that you do not .... 3–28 connect the motor or inverter to live wiri

Summary of the content on the page No. 9

viii WARNING: During a trip event, if the alarm reset is applied and the Run ....... 4–3 command is present, the inverter will automatically restart. Be sure to apply the alarm reset only after verifying the Run command is OFF. Otherwise, it may cause injury to personnel. WARNING: Be sure not to touch the inside of the energized inverter or to ....... 4–3 put any conductive object into it. Otherwise, there is a danger of electric shock and/or fire. WARNING: If power is turned ON when the Run

Summary of the content on the page No. 10

ix L100 Inverter Warnings and Cautions for Troubleshooting and Maintenance WARNING: Wait at least five (5) minutes after turning OFF the input ...... 6–2 power supply before performing maintenance or an inspection. Other- wise, there is the danger of electric shock. WARNING: Make sure that only qualified personnel will perform ...... 6–2 maintenance, inspection, and part replacement. Before starting to work, remove any metallic objects from your person (wristwatch, bracelet, etc.). Be sure to

Summary of the content on the page No. 11

x CAUTION: Do not stop operation by switching OFF electromagnetic contactors on the primary or secondary sides of the inverter. Ground fault interrupter Power Input U, V, W L1, L2, L3 Motor Inverter P24 FW When there has been a sudden power failure while an operation instruction is active, then the unit may restart operation automatically after the power failure has ended. If there is a possibility that such an occurrence may harm humans, then install an electro- magnetic contactor (Mgo) o

Summary of the content on the page No. 12

xi L100 Inverter CAUTION: SUPPRESSION FOR NOISE INTERFERENCE FROM INVERTER The inverter uses many semiconductor switching elements such as transistors and IGBTs. Thus, a radio receiver or measuring instrument located near the inverter is susceptible to noise interference. To protect the instruments from erroneous operation due to noise interference, they should be used well away from the inverter. It is also effective to shield the whole inverter structure. The addition of an EMI filter on t

Summary of the content on the page No. 13

xii CAUTION: When the EEPROM error E08 occurs, be sure to confirm the setting values again. CAUTION: When using normally closed active state settings (C_11 to C_15) for exter- nally commanded Forward or Reverse terminals [FW] or [RV], the inverter may start automatically when the external system is powered OFF or disconnected from the inverter! So, do not use normally closed active state settings for Forward or Reverse terminals [FW] or [RV] unless your system design protects against uninten

Summary of the content on the page No. 14

xiii L100 Inverter Terminal Tightening Torque and Wire Size The wire size range and tightening torque for field wiring terminals are presented in the table below. Motor Output Torque Input Wiring Size Inverter Model Voltage Range (AWG) kW HP ft-lbs (N-m) 0.2 1/4 L100-002NFE/NFU 0.6 0.8 0.4 1/2 L100-004NFE/NFU 16 0.55 3/4 L100-005NFE 0.75 1 L100-007NFE/NFU 14 1.1 1 1/2 L100-011NFE 200V 0.9 1.2 1.5 2 L100-015NFE/NFU 12 2.2 3 L100-022NFE/NFU 10 3.7 5 L100-037LFU 12 5.5 7 1/2 L100-055LFU 10 1.5 2.

Summary of the content on the page No. 15

xiv Circuit Breaker and Fuse Sizes The inverter’s connections to input power must include UL Listed inverse time circuit breakers with 600V rating, or UL Listed fuses as shown in the table below. Motor Output Fuse (A) Input Inverter Model (UL-rated, Voltage kW HP class J, 600V) 0.2 1/4 L100-002NFE/NFU 10 (single ph.) 7 (three ph.) 0.4 1/2 L100-004NFE/NFU 0.55 3/4 L100-005NFE 0.75 1 L100-007NFE/NFU 15 (single ph.) 10 (three ph.) 1.1 1 1/2 L100-011NFE 1.5 2 L100-015NFE/NFU 20 (single ph.) 200V

Summary of the content on the page No. 16

xv L100 Inverter Table of Contents Safety Messages Hazardous High Voltage i General Precautions - Read These First! ii Index to Warnings and Cautions in This Manual iv General Warnings and Cautions

Summary of the content on the page No. 17

xvi Chapter 4: Operations and Monitoring Introduction 4–2 Connecting to PLCs and Other Devices 4–4 Example Wiring Diagram 4–5 Using Intelligent Input Terminals

Summary of the content on the page No. 18

xvii L100 Inverter Revisions Revision History Table Operation No. Revision Comments Date of Issue Manual No. Initial Release of Manual NB576X May 1999 NB576X 1 Revision A August 1999 NB576XA Pages 1-4 – Specs tables: added row for input current, changed rated input voltage tolerance, corrected dynamic braking %torque, corrected product weight (lbs) Page 2-8 – Corrected H dimension for -002 models 2 Revision B May 2002 NB576XB Updated company name on cover, contact page, and nameplate phot

Summary of the content on the page No. 19

xviii Contact Information Hitachi America, Ltd. Hitachi Australia Ltd. Power and Industrial Division Level 3, 82 Waterloo Road 50 Prospect Avenue North Ryde, N.S.W. 2113 Tarrytown, NY 10591 Australia U.S.A. Phone: +61-2-9888-4100 Phone: +1-914-631-0600 Fax: +61-2-9888-4188 Fax: +1-914-631-3672 Hitachi Europe GmbH Hitachi Industrial Equipment Systems Co, Ltd. Am Seestern 18 International Sales Department D-40547 Düsseldorf WBG MARIVE WEST 16F Germany 6, Nakase 2-chome Phone: +49-211-5283-0 Mi

Summary of the content on the page No. 20

Getting Started 1 In This Chapter.... page — Introduction ..................................................... 2 — L100 Inverter Specifications............................ 5 — Introduction to Variable-Frequency Drives .... 17 — Frequently Asked Questions ......................... 22


Alternative user manuals
# User manual Category Download
1 Hitachi L100 User manual Power Supply 301
2 Hitachi SJ300-037HFE User manual Welding System 6
3 Hitachi CONVENTION 14 User manual Welding System 1
4 Hitachi SJ700 User manual Welding System 3
5 Hitachi SJ700-2 Series User manual Welding System 133
6 Hitachi L300P Series User manual Welding System 232
7 Hitachi L300IP User manual Welding System 5
8 Hitachi SJ300 User manual Welding System 108
9 Hitachi SJ2002 User manual Welding System 1
10 Sony 6 User manual Welding System 0
11 ADTRAN NT1 T400 User manual Welding System 1
12 AEG 2000 User manual Welding System 2
13 AEG PV 2000 User manual Welding System 8
14 Agilent Technologies AC Power Solutions 6814B User manual Welding System 8
15 Agilent Technologies 5743A User manual Welding System 0