White Rodgers 2A37 user manual

User manual for the device White Rodgers 2A37

Device: White Rodgers 2A37
Category: Weather Radio
Manufacturer: White Rodgers
Size: 0.09 MB
Added : 5/14/2014
Number of pages: 6
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for White Rodgers 2A37. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with White Rodgers 2A37.

For your convenience

If looking through the White Rodgers 2A37 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual White Rodgers 2A37 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual White Rodgers 2A37 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
White Rodgers 2A37 User manual - Online PDF
Advertisement
« Page 1 of 6 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual White Rodgers 2A37 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to White Rodgers 2A37. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TYPE 2A37
HEATING
WHITE-RODGERS TEMPERATURE CONTROL
Adjustable Differential
INSTALLATION INSTRUCTIONS
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
This Hydraulic-Action temperature control is readily ap-
plicable for many types of commercial or industrial heat-
ing applications.
The speed of response of the temperature sensitive
el

Summary of the content on the page No. 2

INSTALLATION The control may be mounted in any location provided that CAUTION the temperature and humidity of the air in which it is Do not twist or uncoil the coiled bulb on the top of located will not cause a condensation on the switch parts. the control case. Do not attach conduit through 1. The control should be mounted approximately six feet coiled element to top of control. Instead, run con- from the floor. duit to bottom of control. 2. If the electric conduit goes to a warmer room, put ro

Summary of the content on the page No. 3

SETTING THE CONTROL The movable indicator points to the temperature at which the contacts open. The fixed indicator points to the tem- “B” FIXED INDICATOR perature at which the contacts close. The difference (CUT-IN POINT) between these two indicators is the differential. “C” DIFFERENTIAL ADJUSTING SCREW To set the control: “D” MOVABLE INDICATOR 1. Use a screwdriver in the adjusting slot (A) on the front (CUT-OUT POINT) of the control to turn the dial so that the fixed indicator “A” ADJUSTING (B

Summary of the content on the page No. 4

TYPE 2A37 RÉGULATEUR DE TEMPÉRATURE DE CHAUFFAGE WHITE-RODGERS Différentiel réglable INSTRUCTIONS D’INSTALLATION Utilisateur: conservez ces instructions pour vous y référer au besoin! SI VOUS NE LISEZ PAS ATTENTIVEMENT CES INSTRUCTIONS AVANT D’INSTALLER ET D’UTILISER LA COMMANDE, VOUS RISQUEZ DE CAUSER DES BLESSURES ET DES DOMMAGES MATÉRIELS. DESCRIPTION Ce régulateur de température à mécanisme hydraulique s’adapte à plusieurs types de systèmes de chauffage commercial ou industriel. La rapidité

Summary of the content on the page No. 5

INSTALLATION Le régulateur peut être placé à n’importe quel endroit ATTENTION pourvu que la température et l’humidité de l’air ambiant n’entraînent pas de condensation sur les pièces de Ne pas tordre ou dérouler le serpentin situé sur le l’interrupteur. dessus du boîtier. Ne pas fixer de conduit au 1. Installer le régulateur environ à deux mètres (six pieds) régulateur en le passant au centre du serpentin, du sol. mais le raccorder plutôt au dessous du régulateur. 2. Si le conduit électrique tra

Summary of the content on the page No. 6

RÉGLAGE DE LA COMMANDE RÉGULATEUR À DIFFÉRENTIEL REGLABLE L’indicateur mobile donne la température à laquelle le compresseur sera mis en marche. L’indicateur fixe donne la température à laquelle le compresseur sera arrêté. Le (B) INDICATEUR FIXE différentiel est l’écart entre ces deux indicateurs. (POINT D’ENCLENCHEMENT) Pour régler le régulateur, procéder de la façon suivante : (C) VIS DE RÉGLAGE 1. Introduire un tournevis dans la fente de réglage (A) DU DIFFÉRENTIEL située sur l’avant de la co


Alternative user manuals
# User manual Category Download
1 White Rodgers 1050 User manual Weather Radio 1
2 White Rodgers 259-6 User manual Weather Radio 1
3 White Rodgers 1F62-21 User manual Weather Radio 1
4 White Rodgers 37-1896C User manual Weather Radio 1
5 Sony 443 User manual Weather Radio 1
6 3Com WL-548A User manual Weather Radio 0
7 Acu-Rite #75077 User manual Weather Radio 3
8 Acu-Rite 00305TG User manual Weather Radio 1
9 Acu-Rite 00593W User manual Weather Radio 4
10 3Com 6100 User manual Weather Radio 2
11 Sony User manual Weather Radio 2
12 Sony SRF-M85V User manual Weather Radio 102
13 Acu-Rite 00608BPDI User manual Weather Radio 9
14 Acu-Rite #08560 User manual Weather Radio 1
15 Acu-Rite #00837WI User manual Weather Radio 2