Anaheim H300 user manual

User manual for the device Anaheim H300

Device: Anaheim H300
Category: Weather Radio
Manufacturer: Anaheim
Size: 0.24 MB
Added : 5/4/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Anaheim H300. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Anaheim H300.

For your convenience

If looking through the Anaheim H300 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Anaheim H300 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Anaheim H300 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Anaheim H300 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Anaheim H300 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Anaheim H300. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTRUCTION MANUAL
Models: H300
Humidity/Temp Meter
with DEW Point and Data Logger

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Table of Content 1. Product Introduction ………………………………………… 3 1-1 Features ………………….………………………… 3 1-2 Applications ……………………………………...… 3 2. Safety Information …………………………………………… 4 2-1 Cautions ………………………………..………..… 4 2-2 Safety Symbols ………………………..…..……… 4 3. Specifications……………………………………...…………. 5 4. Operation Instructions……………………………………… 6 4-1 Unit Diagram ……………………………………… 6 4-2 Measuring Procedure ……………………….…... 7 4-3 Humidity & Temperature Measurement ..……… 7 4-4 DEW Point Measurement .…………….………… 7 4-5

Summary of the content on the page No. 4

1. Product Introduction 1-1 Features  Humidity, Temperature and Dew Point measure ments  0.01 Resolution for Te mperature and RH measure ments  Fast response ti me  High level of accuracy  Large LCD display  Two year warranty 1-2 Applications  Science Experiments  HVAC  Plant Maintenance  Manufacturing  Agriculture  Quality Control 3

Summary of the content on the page No. 5

2. Safety Information Read the follow ing safety information carefully before attempting to operate or serv ice the meter. Only qualified personnel should perform repairs or serv icing not cov ered in this manual. 2-1 Cautions! DO NOT submerge the products mentioned in this manual in w ater or any other ty pes of liquids. This product is not designed for use in medical applications. The product can only be used to measure body temperature simply for reference. 2-2 Safety Symbols Dangerous, ref

Summary of the content on the page No. 6

5. Specifications Display 5 Digit LCD with bar graph indicator Unit of Measurement Humidity: %RH (Relative Humidity) Temperature: °C or °F Dew Point: °C or °F Temperature Compensation Automatic for humidity function Sampling Time of Data Logger Manual Pushing the data logger button once will save data one time Auto 1, 2, 10, 30, 60, 600, 1800, 3600 seconds Humidity / Temperature Range 0% to 95% RH Resolution 0.01% RH Humidity Accuracy >70%RH +(3% rdg. + 1% RH) <70%RH - 3%RH +3%RH Range 32°F to 1

Summary of the content on the page No. 7

4. Operation Instructions The H300 could take as long as ten minutes for the display to completely“ settle” and display the actual temperature or relative humidity level if the meter is exposed to two vastly different environments. The sensors used to make the environmental measurements must have time to acclimate to the test environment. 4-1 Unit Diagram Fig. 1 4-1 LCD Display 4-9 RS232 Socket 4-2 Power button 4-10 Probe Input Socket 4-3 Hold Button (ESC Button) 4-11 Probe Plug 4-4 REC Button (

Summary of the content on the page No. 8

4-2 Measuring Procedure The H300 default unit of measure is °C. To switch to °F see section 5-1. The sampling time default for data logging is set at 2 seconds. To change this sampling time see section 4-7. 4-3 Humidity & Temperature Measurement 1. Plug the “ Probe Plug” (4-11, Fig. 1) into the “ Probe Input Socket” (4-10, Fig. 1). 2. Power on the meter by pressing the “ Power Button” (4-2, Fig.1) for 2 seconds. The LCD will show the units of measure on the displayafter a quick self test. It wil

Summary of the content on the page No. 9

7. Press the “ REC Button” (4-4, Fig.1) momentarily to start the data log function. The REC symbol will be displayed on the LCD. The data logger function can save up to 1000 values of measure (either Humidity & Temp. or Dew Point & Te mp). 8. Press the “Logger Button” (4-6, Fig.1) and the meter will start logging. You will see the A flashing on the top of the LCDevery time a logging event has occurred. The A flashing will match the number of seconds you set in the setup of the data logger functi

Summary of the content on the page No. 10

5. Advanced Measuring Procedures Note: Cancel any Hold or Record functions before trying to perform and advanced measuring procedures. 1. Press and hold the “ SET Button” (4-6, Fig. 1) for about 3 seconds until the LCD displays “ Code” . Once you release the button you should see 1000 in the main display. 1000 Is the password code to allow advanced measuring procedures. To leave the setting menu press the “ ESC Button” (4-3, Fig.1). 2. Press the “ Enter Button” (4-4, Fig. 1). 4. Now you are in t

Summary of the content on the page No. 11

5-4 Clear Memory 1. Press and hold the “ Set Button” (4-6, Fig.1) for about 3 seconds. 2. The main LCD should then display1000. Now press the “ Enter Button” (4-4-, Fig. 1). 3. Press the “ Set Button” (4-6, Fig.1) three times and you will see the CLr marker in the bottom of the LCD. The top number is the number of stored data points. 4. Press the “ Function Button” (4-5, Fig. 1) and the top number will go to zero. 5. Press the “ Enter Button” (4-4-, Fig. 1) to clear memory. 6. You can press the

Summary of the content on the page No. 12

7. Send Data from RS232 Socket 1. Cancel Hold and REC functions. 2. Press and hold the “ Send Button” (4-5, Fig. 1) for about 2 seconds. You will see 232 in the bottom of the LCD. 3. Press the “ Send Button” (4-5, Fig. 1) and both the top and bottom display will begin to flash. At this ti me the data is being sent out the “ RS232 Socket” (4-9, Fig.1). 8. RS232 PC Serial Interface Information This instrument has RS232 PC serial interface via a 3.5 mm terminal (4-12, Fig. 1). The data output is a

Summary of the content on the page No. 13

The 16 digit data stream will be displayed in the following format: D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1D0 Each digit indicates the following status: D15 Start Word D14 4 D12 & D11 Indicator for Display °C = 01 °F = 02 % RH = 04 D10 Polarity: 0 = Positive / 1 = Negative Decimal Point (DP), position from right to left D9 0 = No DP, 1 = 1 DP, 2 = 2 DP, 3 = 3 DP Display reading, D1 = LSD, D8 = MSD Example: If the display reading is 1234, D8 to D1 then D8 to D1 is: 00001234 D0 End Word

Summary of the content on the page No. 14

10. Service Information Warranty Service: Please return the product in the original packaging with proof of purchase to the address below . Clearly state in writing the performance problem and return any leads, probes, connectors and accessories that you are using w ith the device. Non-Warranty Service: Return the product in the original packaging to the address below . Clearly state in w riting the performance problem and return any leads, probes, connectors and accessories that you are using w

Summary of the content on the page No. 15

11. Limited Two-Year Warranty Anaheim Scientific w arrants to the original purchaser that its products and the component parts thereof, w ill be free from defects in workmanship and materials for a period of tw o years from date of purchase from an authorized Anaheim Scientific distributor. Anaheim Scientific w ill, w ithout charge, repair or replace, at its option, defective product or component parts. Returned product must be accompanied by proof of the purchase date in the form of a sales rec

Summary of the content on the page No. 16

Anaheim Scientific 22820 Savi Ranch Parkw ay Yorba Linda, CA 92887 U.S.A. www.anaheimscientific.com Printed in Taiw an / Ver. 1.0/0606 © 2006 Anaheim Scientific Corporation


Alternative user manuals
# User manual Category Download
1 Sony 443 User manual Weather Radio 1
2 3Com WL-548A User manual Weather Radio 0
3 Acu-Rite #75077 User manual Weather Radio 3
4 Acu-Rite 00305TG User manual Weather Radio 1
5 Acu-Rite 00593W User manual Weather Radio 4
6 3Com 6100 User manual Weather Radio 2
7 Sony User manual Weather Radio 2
8 Sony SRF-M85V User manual Weather Radio 102
9 Acu-Rite 00608BPDI User manual Weather Radio 9
10 Acu-Rite #08560 User manual Weather Radio 1
11 Acu-Rite #00837WI User manual Weather Radio 2
12 Acu-Rite 02010-CCDI User manual Weather Radio 9
13 Acu-Rite 02036WB User manual Weather Radio 1
14 Acu-Rite 00594W User manual Weather Radio 4
15 Acu-Rite 01098CDI User manual Weather Radio 2