GE E8-CE user manual

User manual for the device GE E8-CE

Device: GE E8-CE
Category: Water System
Manufacturer: GE
Size: 1.21 MB
Added : 9/6/2013
Number of pages: 17
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for GE E8-CE. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with GE E8-CE.

For your convenience

If looking through the GE E8-CE user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual GE E8-CE on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual GE E8-CE to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
GE E8-CE User manual - Online PDF
Advertisement
« Page 1 of 17 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual GE E8-CE but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to GE E8-CE. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

E4H-CE AND E8-CE SERIES
WATER PURIFICATION
MACHINES
3 3
3 m /hr to 45 m /hr
18,000 gpd to 288,000 gpd
Control Narrative
Manual

Summary of the content on the page No. 2

Summary of the content on the page No. 3

GE OSMONICS E4H-CE AND E8-CE WATER TREATMENT SYSTEMS CONTROL NARRATIVE MANUAL TABLE OF CONTENTS Page 1.0 OVERVIEW 1 1.1 Hardware 1 1.2 Software 1 1.3 Operator Interface Terminal (OIT) 2 2.0 START-UP 3 2.1 Operation Screen 4 2.2 Alarm History Screen 6 2.3 Machine Status Screen 8 2.4 Utilities Screen 10 2.5 Set-Up Screen 11 LIST OF FIGURES Figure Title 2.1 Start-Up Screen 3 2.2 Operation Screen 4 2.3 Alarm History Screen 6 2.4 Machine Status Screen 8 2.5 Utilities Screen 10 2.6 Set-Up Screen 11 LI

Summary of the content on the page No. 4

Summary of the content on the page No. 5

1.0 OVERVIEW The GE Osmonics E4H-CE and E8-CE water treatment systems consist of modular equipment that is designed to work together with the reverse osmosis (RO) machine at the heart of the system. The Programmable Logic Controller (PLC) and Operator Interface Terminal (OIT) are pro- grammed to control a complete, integrated system. A water purification system may consist of the following modular equipment: · Media Filter(s) · Chemical Injection System · Clean-In-Place (CIP) System · Permeate

Summary of the content on the page No. 6

1.3 Operator Interface Terminal (OIT) Screen The available screens for the PanelView are as listed: START-UP: Contact information for customer. OPERATION: Gives run options for machine, alarm, and status messages. ALARM HISTORY: Displays last five alarms conditions. STATUS: Displays last five operating conditions. UTILITIES: Adjusts contrast, screen center, and allows user to clean dis- play. SET-UP: Allows user to clear alarm history, run time, and status. Allows user to download new program in

Summary of the content on the page No. 7

2.0 START-UP The START-UP Screen is displayed upon start-up of the E-CE Series RO machine. This touch screen gives customer contact information. Figure 2.1 Start-Up Screen To get to the next screen, press anywhere on the screen or wait twenty (20) seconds. 3

Summary of the content on the page No. 8

2.1 Operation Screen The Operation Screen displays the control function for the E-CE Series RO machine. 3 4 11 1 5 2 6 12 10 7 89 Figure 2.2 Operation Screen NO. FUNCTION OPERATION NO. FUNCTION OPERATION 1 RO Switches machine to run 7 INFORMATION Takes User to Information Screen 2 AUTO/HAND Switches machine to Auto 8 ALARM Takes User to Alarm Screen or Hand 3 CIP Switches machine to CIP mode 9 ALARM RESET Resets current Alarm 4 FILL Energizes the inlet solenoid valve 10 UTILITIES Takes User to U

Summary of the content on the page No. 9

The RO machine is controlled using the Operation Screen. The FILL button energizes the inlet solenoid valve allowing the RO machine to fill water. The machine will run for ten (10) minutes filling the machine. This needs to be done before the RO machine can oper- ate. Once the machine has been filled the RO, CIP, and PURGE buttons will operate. The RO button controls the RO machine when it is in Run Mode. If the RO machine is not in Run Mode, the RO button switches the RO machine from its c

Summary of the content on the page No. 10

2.2 Alarm History Screen The ALARM Message, located above the Control Buttons, shows the user current Alarm Conditions. 5 4 1 3 2 Figure 2.3 Alarm History Screen NUMBER FUNCTION OPERATION 1 BACK Takes user back to OPERATION Screen 2 ALARM Takes user to ALARM Screen 3 ALARM RESET Resets current ALARM conditions 4 UTILITIES Takes users to UTILITIES Screen 5 ALARM HISTORY Displays the last 5 Alarm Conditions 6

Summary of the content on the page No. 11

Table 2.1 Alarm Messages ALARM ACTION NOTES DISPLAY FACTORY SET DISPLAYED (seconds) POINTS* LOW INLET Shuts down RO Press ALARM 12 Adjustable switch PRESSURE machine RESET on OIT [set at 0.8 bar (12 psi)] HI PERMEATE Shuts down RO Press ALARM 0 Adjustable switch PRESSURE machine RESET on OIT [set at 5.5 bar (80 psi)] HI TEMP Shuts down RO Press ALARM 0 Non-adjustable machine RESET on OIT switch [set at 38°C (100°F)] HIGH Alarm light dis- RO machine will None Adjustable switch pH played on pH op

Summary of the content on the page No. 12

2.3 Machine Status Screen The Machine Status Screen displays the last five run conditions. 1 4 23 Figure 2.4 Machine Status Screen NUMBER FUNCTION OPERATION 1 BACK Takes user back to OPERATION Screen 2 ALARM Takes user to ALARM Screen 3 ALARM RESET Resets current ALARM Conditions 4 UTILITIES Takes users to UTILITIES Screen 8

Summary of the content on the page No. 13

Table 2.2 Status Screen System Message SYSTEM MESSAGE DEFINITION RO MODE Normal Operating Mode. CIP MODE Clean-In-Place Mode used for cleaning. PERMEATE PURGE MODE Permeate is “recycled” back through RO machine. MANUAL SHUTDOWN RO machine switched OFF by manually pressing ON/OFF button ALARM SHUTDOWN RO machine has shutdown due to one of the Alarms described in Table 2.1. PRETREATMENT SERVICE RO machine has shutdown due to a signal from pretreatment. POST-TREATMENT SERVICE RO machine has shutdow

Summary of the content on the page No. 14

2.4 Utilities Screen The Utilities Screen allows the user to adjust contrast, screen center, and clean the display. 3 1 2 4 5 8 8 7 Figure 2.5 Utilities Screen NO. FUNCTION OPERATION NO. FUNCTION OPERATION 1 CONTRAST + Darkens OIT Screen 5 BACK Takes users back to previous screen 6 INFORMATION Takes users to Utilities 2 CONTRAST - Lightens OIT Screen Screen 7 ALARM Takes users to Alarm Screen 3 CALIBRATE Allows users to adjust SCREEN position of OIT Screen 8 SET-UP Takes users to Set-Up 4 CLEA

Summary of the content on the page No. 15

2.5 Set-Up Screen The Set-Up Screen allows the users to clear Alarm History, run time, and status. This Screen allows users to download new program information. 1 2 3 4 5 8 6 7 Figure 2.6 Screen Set-Up NO. FUNCTION OPERATION NO. FUNCTION OPERATION 1* ALARM Clears history of Alarm 5 BACK Takes users back to previous screen HISTORY conditions 6 INFORMATION Takes users to Information 2* STATUS Clears history of system Screen HISTORY conditions 7 UTILITIES Takes users to Utilities 3* RUN TIME Al

Summary of the content on the page No. 16

Summary of the content on the page No. 17

Call (952) 933-2277 for additional information, (800) 766-2599 in the U.S., or visit w w w.osmonics.com Manufactured in the USA Corporate Headquarters Euro/Africa Operations Asia/Pacific Operations 5951 Clearwater Drive 230 rue Robert Schuman 1044/8 SOI 44/2 Minnetonka, MN ZA des Uselles Sukhumvit Road Prakanong 55343-8995 F-77350 Le MØe sur Seine Bangkok 10110 USA FRANCE THAILAND (952) 933-2277 Phone +33 1 64 10 2000 Phone +66 2 38 14213 Phone (952) 933-0141 Fax +33 1 64 10 3747 Fax +66 2 39 18


Alternative user manuals
# User manual Category Download
1 GE 215C1044P010-3 User manual Water System 6
2 GE 268 User manual Water System 17
3 GE 263 User manual Water System 10
4 GE 3020511 User manual Water System 1
5 GE E2 Series User manual Water System 2
6 GE 000 gpd to 288 User manual Water System 0
7 GE E4H-CE Series, E8-CE Series User manual Water System 8
8 GE E4H Series User manual Water System 35
9 GE E4 User manual Water System 62
10 GE EZ2 Series User manual Water System 0
11 GE E4LE User manual Water System 0
12 GE E4H-CE User manual Water System 0
13 GE EZ4 User manual Water System 5
14 GE Profile SmartWater ULTRA PLUS FQROPF User manual Water System 4
15 GE SmartWater GXRTQR User manual Water System 5
16 Sony 7 User manual Water System 0
17 3Com ENTERPRISE OS 11.3 User manual Water System 0
18 Acronis VIA C7-M User manual Water System 0
19 Acronis 200 Series User manual Water System 2
20 Acronis Z540 User manual Water System 1