Summary of the content on the page No. 1
MPS Variable Multi Split SYSTEM
Free Joint, 50Hz, R410A
LM50 2004-E1
Summary of the content on the page No. 2
General Description Thank you very much for your special patronage of LG air-conditioners. A high-grade, high-quality, advanced individual air-conditioning system that is able to respond to expanding, more sophisticated housing environment needs. LG Electronics Inc., which has been a top air conditioner maker for the three consecutive years, has developed "MPS(Multi Power System) Variable Multi Split" system that can efficiently control air-conditioning in a better way. Unlike traditional multi
Summary of the content on the page No. 3
2 MPS Variable Multi Split System(50Hz, R410A)
Summary of the content on the page No. 4
LG Airconditioners Product Data TABLE OF CONTENTS Table of contents Page Part 1 Features...............................................................................................7 Part 2 MPS Variable Multi-Split system (R410A).......................................11 2004 Product Data 3
Summary of the content on the page No. 5
4 MPS Variable Multi Split System(50Hz, R410A)
Summary of the content on the page No. 6
Part 1 Features 2004 Product Data 5
Summary of the content on the page No. 7
Features & Benefit MPS(Multi Power System) Variable Control : (Except A2UC146FA0,A2UH146FA0) Big Energy Saving with MPS Variable Control • Basic Principle of MPS Variable Control MPS control provides comfortable and convenient environment as there are two compressors with 60&40% load sharing with on compressor of small capacity always working to maintain the set temperature conditions & meanwhile other compressor is at rest if the load is low whereas in conventional system the only compressor is
Summary of the content on the page No. 8
Features & Benefit (ppm) Air Purifying System 500 Normal Filter - It not only removes microscopic contaminants & dust, but it + + + + 400 also removes house mites, pollen, and pet fur to help pre- 300 + + + + vent allergic diseases like asthma.It provides odor free, dust free and allergy free air. + + + + 200 100 + + + + Nano Filter • Effect of carbon Nano Ball 0 30 60 90(Min) Deodorizing efficieny: 8~10times compared to conventional carbon filter. • What is Carbon Nano Ball? Nano(1/1 Bil) ball
Summary of the content on the page No. 9
Features & Benefit Ultra-Slim design(Depth 129mm) 129 mm Thinnest Turbo Fan 3-Dimensional Cooling System New Cube 3-Dimension cooling system of ART COOL has Indirect Cooling mode for sleep operation. Being in sleep operation, cool air is discharged only right/left side! Indirect cooling ensures you nice sleep. Improved value of the 3-Dimensional Cooling Improved value of the 3-Dimensional Cooling Vertical Temperature Horizontal Temperature Vertical Temperature Horizontal Temperature Time Reac
Summary of the content on the page No. 10
Features & Benefit Environment Friendly Refrigerant : - LG Air conditioners uses environment friendly refrigerant. Which don't do any harm to the environment. Jet Cool: - In this mode very quick and fast cooling is done. The unit will continue to supply high velocity air for 30 min- utes, untill the room temperature reaches 18°C. After 30 minutes, unit will supply air at the set fan speed whether indoor temperature has reached 18°C or not. Self Diagnosis Function: - This function provides diag
Summary of the content on the page No. 11
10 MPS Variable Multi Split System(50Hz, R410A)
Summary of the content on the page No. 12
Part 2 MPS Variable Multi-Split System R410A, Cooling Only/Heat Pump AMNC076LQL0 AMNC096AP*1 A2UC146FA0 AMNC096LQL0 AMNC126AP*1 A2UC186FA0 AMNC126LRL0 A3UC216FA0 AMNC186LTL0 A4UC306FA0 AMNC246LTL0 AMNH076LQL0 AMNH096AP*1 A2UH146FA0 AMNH096LQL0 AMNH126AP*1 A2UH186FA0 AMNH126LRL0 A3UH216FA0 AMNH186LTL0 A4UH306FA0 AMNH246LTL0 1. Power Supply .................................................................................................................12 2. Model Number Nomenclatur
Summary of the content on the page No. 13
1. Power Supply Type Outdoor Unit Power Supply A2UC146FA0 A2UC186FA0 Cooling Only A3UC216FA0 A4UC306FA0 1Ø, 220~240V, 50Hz A2UH146FA0 Heat Pump A2UH186FA0 A3UH216FA0 A4UH306FA0 Note : Power Supply Intake ; Outdoor Unit Only External wiring procedure - The power supply is needed only to the outdoor unit. The power supply to the indoor unit Is conducted through the transmission wiring. Therefore, the power supply can be given at just one place. It will contribute to simplify the work procedure and
Summary of the content on the page No. 14
2. Model Number Nomenclature 2.1 Indoor Units AMN H 07 6 L Q L 0 Serial Number Combination of Functions L : Nano Plasma ART COOL Type Front Panel Color B : Blue, D : Wood, M : Metal Chassis Name Indoor Unit Type L : Wall Mounted A : ART COOL Electrical Ratings 6: 1ø, 220~240V, 50Hz Nominal Cooling Capacity in Btu/h Ex) 7,000 Btu/h ‘07’ , 18,000 Btu/h ‘18’ Model Type C: Cooling Only H: Heat Pump Multi Split System Indoor Unit 2.2 Outdoor Units A3U H 21 6 F A 0 Serial Number Function A: Ba
Summary of the content on the page No. 15
3. Outline of System The system has number of indoor units attached to an outdoor unit which saves energy while in operation. This system can be installed in small space and cooling can be controlled in each room individually. 3.1 Example of System [A4UH306FA0] 3.2 Combination of Indoor and Outdoor Unit Indoor Units Outdoor Unit A2UC146FA0 A2UC186FA0 A3UC216FA0 A4UC306FA0 Capacity A2UH146FA0 A2UH186FA0 A3UH216FA0 A4UH306FA0 Model No. of Connectable Indoor Units Type Index kW Btu/h 2234 7 2.1 700
Summary of the content on the page No. 16
3. Outline of System 3.3 External Appearance of Indoor Units Wall Mounted ART COOL AMNC076LQL0 AMNH076LQL0 AMNC096AP*1 AMNH096AP*1 AMNC096LQL0 AMNH096LQL0 AMNC126AP*1 AMNH126AP*1 AMNC126LRL0 AMNH126LRL0 AMNC186LTL0 AMNH186LTL0 AMNC246LTL0 AMNH246LTL0 '* : Front Panel Color B : Blue D : Wood M : Metal 2004 Product Data 15
Summary of the content on the page No. 17
4. List of Functions Model AMNC-LQ/LR/LT AMNC-AP AMNH-LQ/LR/LT AMNH-AP Features Airflow Direction Control(Left & Right) Manual Manual Manual Manual Airflow Direction Control(Up & Down) Automatic Automatic Automatic Automatic Airflow Outlet 1 3 1 3 Airflow Steps(Fan / Cool / Heat) 3/4/3 3/4/3 3/4/3 3/4/3 Auto Changeover(Operation) - - - - Auto Cleaning - O - O Auto Restart Operation O O O O Central Control Accessory Accessory Accessory Accessory CHAOS Wind(Auto Wind) O O O O Child Lock Function -
Summary of the content on the page No. 18
5. Specifications 5.1 Indoor Units Cooling Only Indoor Unit Type Wall Mounted Model AMNC076LQL0 AMNC096LQL0 AMNC126LRL0 AMNC186LTL0 AMNC246LTL0 Nominal Cooling Capacity kcal/hr(W) 1764(2051) 2267(2638) 3024(3515 4536(5275) 5795(6740 Btu/hr 7000 9000 12000 18000 23000 Nominal Heating Capacity kcal/hr(W) -- - - - Btu/hr -- - - - Air Circulation H/M/L CMM(CFM) 5.5(194) 6.0.(212) 9.0(318) 13(459) 14(495) Setting temperature range °C 18~30 / - 18~30 / - 18~30 / - 18~30 / - 18~30 / - Fan motor O
Summary of the content on the page No. 19
5. Specifications Heat Pump Indoor Unit Type Wall Mounted Model AMNH076LQL0 AMNH096LQL0 AMNH126LRL0 AMNH186LTL0 AMNH246LTL0 Nominal Cooling Capacity kcal/hr(W) 1764(2051) 2267(2638) 3024(3515) 4536(5275) 5796(6740) Btu/hr 7000 9000 12000 18000 23000 Nominal Heating Capacity kcal/hr(W) 2016(2343) 2520(2929) 3326(3867) 4990(5803) 6426(7472) Btu/hr 8000 10000 13200 19800 25500 Air Circulation H/M/L CMM(CFM) 5.5(194) 6.0(212) 9.0(318) 13(459) 14(495) Setting temperature range °C 18~30 / 16~30
Summary of the content on the page No. 20
5. Specifications 5.2 Outdoor Units Cooling Only A2UC146FA0 A2UC186FA0 A3UC216FA0 A4UC306FA0 Model Cooling Capacity kcal/hr 2268~3780 1764~4536 2016~5292 2268~7560 W 2636~4394 2051~5275 2345~6154 2638~8787 Btu/hr 9000~15000 7000~18000 8000~21000 9000~30000 Heating Capacity kcal/hr -- - - W -- - - Btu/hr -- - - Input Cooling/Heating W 1300~1400 / - 780~1900/ - 880~2100/ - 1100~3250 / - Running Current Cooling/Heating A 6.1~6.7 / - 3.5~8.5/ - 4.0~9.4/ - 4.8~15 / - Starting Current Cooling