Emerson PN 51-1055pHC/rev.K user manual

User manual for the device Emerson PN 51-1055pHC/rev.K

Device: Emerson PN 51-1055pHC/rev.K
Category: Water System
Manufacturer: Emerson
Size: 1.12 MB
Added : 7/24/2014
Number of pages: 87
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson PN 51-1055pHC/rev.K. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson PN 51-1055pHC/rev.K.

For your convenience

If looking through the Emerson PN 51-1055pHC/rev.K user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson PN 51-1055pHC/rev.K on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson PN 51-1055pHC/rev.K to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson PN 51-1055pHC/rev.K User manual - Online PDF
Advertisement
« Page 1 of 87 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson PN 51-1055pHC/rev.K but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson PN 51-1055pHC/rev.K. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Instruction Manual
PN 51-1055pHC/rev.K
February 2006
®
Model Solu Comp II
Dual Input pH/Conductivity Analyzer

Summary of the content on the page No. 2

ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK READ THIS PAGE BEFORE PROCEEDING! Your purchase from Rosemount Analytical, Inc. has Equipment protected throughout by double insulation. resulted in one of the finest instruments available for your particular application. These instruments have • Installation of cable connections and servicing of this prod- been designed, and tested to meet many national uct require access to shock hazard voltage levels. and international standards.

Summary of the content on the page No. 3

QUICK START GUIDE FOR MODEL SOLU COMP II pH/CONDUCTIVITY ANALYZER (Model Option 1055-22-30) 1. Refer to Section 2.0 for installation instructions. 2. Wire sensor(s) to the analyzer. See the drawings below. Refer to the sensor instruction sheet for details. Make alarm and output connections as shown below. NOTE For sensors without solution ground, please use the RC kit included with the instrument. Wiring Connections for Solu Comp II Model 1055-01-10 Wiring Connections for Solu Comp II Model 1055

Summary of the content on the page No. 4

4. When the analyzer is powered up for the first time, Quick Start screens appear. Using Quick Start is easy. a. A blinking field shows the position of the cursor. b. Use the  or  key to move the cursor left or right. Use the  or  key to move the cursor up or down or to increase or decrease the value of a digit. Use the  or  key to move the decimal point. c. Press ENTER to store a setting. Press EXIT to leave without storing changes. Pressing EXIT also returns the display to the previou

Summary of the content on the page No. 5

QUICK REFERENCE GUIDE MENU TREE FOR pH/ORP/REDOX/CONDUCTIVITY/RESISTIVITY/TDS MEASUREMENTS pH/cond/temp

Summary of the content on the page No. 6

MODEL SOLU COMP II TABLE OF CONTENTS MODEL SOLU COMP II DUAL INPUT pH/CONDUCTIVITY ANALYZER TABLE OF CONTENTS Section Title Page 1.0 DESCRIPTION AND SPECIFICATIONS ................................................................ 1 1.1 Features and Applications........................................................................................ 1 1.2 Specifications........................................................................................................... 2 1.3 Ordering Informat

Summary of the content on the page No. 7

MODEL SOLU COMP II TABLE OF CONTENTS TABLE OF CONTENTS CONT’D Section Title Page 6.0 CALIBRATION ........................................................................................................ 45 6.1 Introduction .............................................................................................................. 45 6.2 Calibrating Temperature........................................................................................... 46 6.3 Two-Point Buffer Calibration (Auto Cal

Summary of the content on the page No. 8

MODEL SOLU COMP II TABLE OF CONTENTS LIST OF FIGURES Number Title Page 2-1 Panel Mount Installation ........................................................................................... 12 2-2 Pipe Mount Installation ............................................................................................. 13 2-3 Surface Mount Installation........................................................................................ 14 3-1 Removing the Knockouts ...............................

Summary of the content on the page No. 9

About This Document This manual contains instructions for installation and operation of the Solu Comp II Model 1055 Dual Input pH/Conductivity Analyzer. The following list provides notes concerning all revisions of this document. Rev. Level Date Notes 0 1/01 This is the initial release of the product manual. The manual has been reformatted to reflect the Emerson documentation style and updated to reflect any changes in the product offering. A 2/02 Revised specs. B 7/02 Added 399 wiring diagram

Summary of the content on the page No. 10

MODEL SOLU COMP II SECTION 1.0 DESCRIPTION AND SPECIFICATIONS SECTION 1.0. DESCRIPTION AND SPECIFICATIONS 1.1 FEATURES AND APPLICATIONS 1.2 SPECIFICATIONS 1.3 ORDERING INFORMATION AND ACCESSORIES ENCLOSURE: The panel mount version fits stan- 1.1 FEATURES AND APPLICATIONS dard ½ DIN panel cutouts, and its shallow depth is The Solu Comp II analyzers offer the choice of sin- ideally suited for easy mounting in Hoffman-type gle or dual sensor input with measurement choices enclosures. A panel

Summary of the content on the page No. 11

MODEL SOLU COMP II SECTION 1.0 DESCRIPTION AND SPECIFICATIONS 1.2 SPECIFICATIONS - General RFI/EMI: EN-61326 Case: ABS (panel-mount), polycarbonate (pipe- and surface-mount). All versions are NEMA 4X/CSA 4 LVD: EN-61010-1 (IP65). Input: Choice of single or dual sensor input with Dimensions measurement choices of pH/ORP, conductivity/ Panel (code -10): 6.10 x 6.10 x 3.72 in. (155 x resistivity, toroidal conductivity, flow, chlorine, dis- 155 x 94.5 mm) solved oxygen, and dissolved ozone. Fiel

Summary of the content on the page No. 12

MODEL SOLU COMP II SECTION 1.0 DESCRIPTION AND SPECIFICATIONS CONTACTING CONDUCTIVITY (Codes -20 and/or -30) Measures conductivity in the range 0 to 20,000 µS/cm. RECOMMENDED SENSORS FOR Display choices are conductivity, resistivity, and TDS CONDUCTIVITY: (total dissolved solids). Three temperature corrections The Solu Comp II is intended for use with the are available: high purity water (dilute sodium chlo- ENDURANCE Model 400 series conductivity sensor ride), cation conductivity (dilute hydroc

Summary of the content on the page No. 13

MODEL SOLU COMP II SECTION 1.0 DESCRIPTION AND SPECIFICATIONS TOROIDAL CONDUCTIVITY (Codes -21 and/or -31) When used with Model Series 200 Toroidal RECOMMENDED SENSORS: Conductivity Sensors, display choices are conductiv- Model 222 Flow-through conductivity sensor ity, resistivity, and percent concentration. The per- Model 225 Clean-in-place conductivity sensor cent concentration selection includes the choice of four common solutions (0-12% NaOH, 0-15% HCl, Model 226 Large bore conductivity sens

Summary of the content on the page No. 14

MODEL SOLU COMP II SECTION 1.0 DESCRIPTION AND SPECIFICATIONS pH/ORP (Codes -22 and/or -32) For use with any standard pH or ORP sensor and all RECOMMENDED SENSORS FOR pH: Uniloc sensors and junction boxes with built-in diag- Model 320B Flow Through pH nostic style preamplifiers, display choices are pH, Model 320HP High Purity pH ORP or Redox. The automatic buffer recognition fea- Model 328A Steam Sterilizable pH ture uses stored buffer values and their temperature Model 370 and 371 EuroSenz pH c

Summary of the content on the page No. 15

MODEL SOLU COMP II SECTION 1.0 DESCRIPTION AND SPECIFICATIONS FLOW (Standard on all models or stand alone, Code -23 and/or -33) For use with most pulse signal flow sensors, the Solu RECOMMENDED SENSORS Comp II's user selectable units of measure include +GF+ Signet 515 Rotor-X Flow sensor Model flow rates in GPM (Gallon per minute), LPM (liters per 515/8510-XX (PN P51530-PO) minute), or m3/hr (cubic meters per hour), and veloci- Fluidyne Flow Sensor Model 2300A ty in ft/sec or m/sec. When config

Summary of the content on the page No. 16

MODEL SOLU COMP II SECTION 1.0 DESCRIPTION AND SPECIFICATIONS DISSOLVED OXYGEN (Code -25) When used with an oxygen permeable membrane- PERFORMANCE SPECIFICATIONS covered amperometric sensor, display choices are Measurement Range: 0-20 ppm (mg/L) dissolved ppb or ppm dissolved oxygen or % saturation. oxygen; 0- 250% saturation Because the permeability of the membrane is a func- Resolution: 0.01 ppm; 0.1 ppb for 499A TrDO sensor tion of temperature, a correction is necessary when (when O <1.00 ppm

Summary of the content on the page No. 17

MODEL SOLU COMP II SECTION 1.0 DESCRIPTION AND SPECIFICATIONS 1.3 ORDERING INFORMATION The Solu Comp II analyzers offer the choice of single or dual sensor input with measurement choices of pH/ORP, conductivi- ty/resistivity, toroidal conductivity, flow, chlorine, dissolved oxygen, and dissolved ozone. See combination guide (on the fol- lowing page) for valid combinations. Standard features include two isolated outputs, three alarm relays, customizable two-line display, and temperature correctio

Summary of the content on the page No. 18

MODEL SOLU COMP II SECTION 1.0 DESCRIPTION AND SPECIFICATIONS COMBINATION GUIDE 5 5 * For D.O. sensors with 22k thermistor, use Suite 1 only. 9

Summary of the content on the page No. 19

MODEL SOLU COMP II SECTION 1.0 DESCRIPTION AND SPECIFICATIONS ACCESSORIES (Weights are rounded up to nearest whole lb or 0.5 kg) PART NUMBER DESCRIPTION WEIGHT SHIPPING WT. 23820-00 Pipe mounting kit, includes U-bolts, mounting bracket, nuts, 2 lb (1.0 kg) 4 lb (2.0 kg) washers, and screws (complete) 23554-00 Gland fittings, PG 13.5, 5 per package 1 lb (0.5 kg) 2 lb (1.0 kg) 9240048-00 Tag, stainless steel (specify marking) 1 lb (0.5 kg) 1 lb (0.5 kg) pH INPUT 9210012 Buffer Solution, 4.01 pH, 1

Summary of the content on the page No. 20

MODEL SOLU COMP II SECTION 2.0 INSTALLATION SECTION 2.0. INSTALLATION 2.1 UNPACKING AND INSPECTION 2.2 INSTALLATION 2.1 UNPACKING AND INSPECTION Inspect the shipping container. If it is damaged, contact the shipper immediately for instructions. Save the box. If there is no apparent damage, unpack the container. Be sure all items shown on the packing list are present. If items are missing, notify Rosemount Analytical immediately. 2.2 INSTALLATION 2.2.1 General Information 1. Although the analyz


Alternative user manuals
# User manual Category Download
1 Sony 7 User manual Water System 0
2 3Com ENTERPRISE OS 11.3 User manual Water System 0
3 Acronis VIA C7-M User manual Water System 0
4 Acronis 200 Series User manual Water System 2
5 Acronis Z540 User manual Water System 1
6 Alto-Shaam CombiGuard FI-23014 User manual Water System 1
7 Adobe version cue CS3 User manual Water System 2
8 Aiphone GF-NS User manual Water System 0
9 Alto-Shaam FI-28727 User manual Water System 0
10 AMC FM DWS 1500 User manual Water System 2
11 Amtrol WELL-X1 User manual Water System 6
12 Amtrol WELL-X-TROL User manual Water System 25
13 Apple Final Cut Pro 6 User manual Water System 51
14 Apple Mac OS X Server 10.5 Leopard User manual Water System 21
15 Argosy Research Twin Alternating Water Conditioning System NF 1.5" Series User manual Water System 0