Fluke HART 744 user manual

User manual for the device Fluke HART 744

Device: Fluke HART 744
Category: Water Dispenser
Manufacturer: Fluke
Size: 0.58 MB
Added : 9/9/2014
Number of pages: 30
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fluke HART 744. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fluke HART 744.

For your convenience

If looking through the Fluke HART 744 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fluke HART 744 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fluke HART 744 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fluke HART 744 User manual - Online PDF
Advertisement
« Page 1 of 30 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fluke HART 744 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fluke HART 744. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
744
Documenting Process Calibrator

HART Mode Users Guide
PN 691292
December 1998
© 1998 Fluke Corporation, All rights reserved. Printed in U.S.A.
All product names are trademarks of their respective companies.

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Table of Contents Title Page Introduction..................................................................................................................... 1 How to Contact Fluke ..................................................................................................... 2 Connecting to a HART Transmitter ................................................................................ 3 Supported vs. Generic Transmitters................................................................

Summary of the content on the page No. 4

744 HART Mode Users Guide Calibrating a Supported HART Transmitter .................................................................... 15 Loop Test.................................................................................................................... 16 Output Trim................................................................................................................. 17 Sensor Trim.............................................................................................

Summary of the content on the page No. 5

List of Tables Table Title Page 1. Supported vs. Non-Supported Instruments............................................................................ 7 iii

Summary of the content on the page No. 6

744 HART Mode Users Guide iv

Summary of the content on the page No. 7

List of Figures Figure Title Page 1. Connecting to a HART Transmitter........................................................................................ 5 2. 744 HART Mode Menu Tree.................................................................................................. 9 3. Block Diagram of a HART Transmitter .................................................................................. 14 v

Summary of the content on the page No. 8

744 HART Mode Users Guide vi

Summary of the content on the page No. 9

Documenting Process Calibrator HART Mode This manual describes how to use HART mode, which is Introduction active when the calibrator is communicating over its serial HART interface to a HART transmitter. Refer to the w Warning 744 Users Manual for safety, analog mode operating To avoid electric shock, read the Safety instructions, specifications, and other general information. Information in the 744 Users Manual before All of the calibrator functions described in the 744 Users you use the Fluke

Summary of the content on the page No. 10

744 HART Mode Users Guide How to Contact Fluke To contact Fluke, call: USA and Canada: 1-888-99-FLUKE (1-888-993-5853) Europe: +31 402-678-200 Japan: +81-3-3434-0181 Singapore: +65- -276-6196 * Anywhere in the world: +1-425-356-5500 Or visit us on the World Wide Web: www.fluke.com 2

Summary of the content on the page No. 11

Documenting Process Calibrator HART Mode Connecting to a HART Transmitter 4. If the transmitter is not powered by a loop power Connecting to a HART Transmitter supply, press the Loop Power softkey to activate 24V To connect to and begin to communicate with a HART loop power. transmitter, refer to Figure 1 and proceed as follows: Note The calibrator provides loop power through an Note internal series resistance of 250 Ω. If you only want a communication connection to If the calibrator shows a m

Summary of the content on the page No. 12

744 HART Mode Users Guide The Active Device screen provides the following information for all transmitters, supported or generic: • Poll address (if not 0) • Model number and Tag ID • PV (Primary Variable) • PVAO (digital representation of the Analog Output) • PV LRV (PV Lower Range Value) • PV URV (PV Upper Range Value) pe06s.bmp • Softkeys for accessing HART operation menus 4

Summary of the content on the page No. 13

V mA mA V RTD RTD CAT SOURCE MEAS 30V 300V MAX MAX 30V 30V MAX MAX Documenting Process Calibrator HART Mode Connecting to a HART Transmitter RTD DOCUMENTING PROCESS CALIBRATOR 744 Transmitter S -PS +PS M MEAS mA SETUP SOURCE Z TC -IN V V Hz RTD +IN 7 89 CLEAR (ZERO) 45 6 12 3 ENTER 0 . TC pe01c.eps Figure 1. Connecting to a HART Transmitter 5

Summary of the content on the page No. 14

744 HART Mode Users Guide 2. If the calibrator is not connected to a HART Supported vs. Generic Transmitters transmitter, press the r key followed by More The calibrator communicates with virtually all HART Choices. transmitters. In addition, the calibrator is programmed to 3. Press the Device Revs softkey. The Browser screen use device-dependent commands for a selection of HART appears. transmitters and their software versions. These are “supported transmitters.” All other transmitters are “gen

Summary of the content on the page No. 15

Documenting Process Calibrator HART Mode Supported vs. Generic Transmitters Table 1. Supported vs. Generic Transmitters (Devices) Menu Operation Supported Transmitter Generic Transmitter Single Point Multidrop Single Point Multidrop Top Level Active Device screen •• • • Setup Basic (read/write, cloning capability) •• • • Sensor (read only) •• • • Device Identification (read/write) •• • • HART Output (read/write) •• • • HART Information (read only) •• • • Service Loop Test • Not Available • Not A

Summary of the content on the page No. 16

744 HART Mode Users Guide Setup Operations Communication Operations The Setup softkey provides access to the following five Figure 2 shows the HART Mode menu tree. Availability of setup functions: some elements in the menus depends on which transmitter you are using, and whether the transmitter is • Basic configured by itself on a current loop or in a multidrop • Sensor connection. • Device Identification • HART Output Viewing Process Variables • HART Information From the Active Device screen pr

Summary of the content on the page No. 17

Documenting Process Calibrator HART Mode Communication Operations (Example) • Tag PV • PV units PROCESS % Range • LRV, URV Basic • Sensor serial number AO • Damping • Sensor lower and SV, TV, QV • Transfer function upper limits • Sensor minimum span Sensor (temperature devices only) • Sensor type • Sensor connections • Software version • Final assembly number Device SETUP •Tag Identification • Message • Date • Description • Write protect HART • Alarm state Output • HART poll addres

Summary of the content on the page No. 18

744 HART Mode Users Guide Sensor Device Identification From the Active Device screen press the Setup and From the Active Device screen press the Setup and Sensor softkeys to access the read-only Sensor Setup Device Identification softkeys to view information about the screen. This is where you can view information about the transmitter. You can program the Tag, Message, Date, sensor in the transmitter, including serial number, limits, and Descriptor registers in the transmitter using this and sp

Summary of the content on the page No. 19

Documenting Process Calibrator HART Mode Communication Operations HART Output HART Information From the Active Device screen press the Setup and HART From the Active Device screen press the Setup and HART Output softkeys to access the read/write HART Output Information softkeys to access the read-only HART screen. Here you can change the Poll Address (0 = single Information screen. This screen shows more complete transmitter, any other address = multidrop), and control information about the tra

Summary of the content on the page No. 20

744 HART Mode Users Guide Service Operations Interaction between Analog Mode and HART Mode The Service softkey provides access to Loop Test, Pressure Zero Trim (where applicable), Output Trim, and Analog mode is normal calibrator operation, as described Sensor Trim operations. For generic transmitters, only in the 744 Users Manual. HART mode is activated when Loop Test, Output Trim, and Pressure Zero Trim are you press the r (HART) key. This action starts available. (See Table 1.) The trim (adj


Alternative user manuals
# User manual Category Download
1 Edelbrock 2475 User manual Water Dispenser 0
2 Sony 2 User manual Water Dispenser 3
3 ADTX User manual Water Dispenser 4
4 Agilent Technologies E4408B User manual Water Dispenser 16
5 AEG PWE9039M User manual Water Dispenser 15
6 Agilent Technologies 8156A User manual Water Dispenser 7
7 Agilent Technologies 8591E User manual Water Dispenser 7
8 Agilent Technologies 8596E User manual Water Dispenser 5
9 Agilent Technologies 8594E User manual Water Dispenser 13
10 Agilent Technologies 8593E User manual Water Dispenser 13
11 Agilent Technologies 856290216 User manual Water Dispenser 1
12 Agilent Technologies 5328B User manual Water Dispenser 1
13 Agilent Technologies E4403B User manual Water Dispenser 29
14 Agilent Technologies 8595E User manual Water Dispenser 3
15 Agilent Technologies E4411B User manual Water Dispenser 44