LG Electronics LG - Life's GoodLSU090CE user manual

User manual for the device LG Electronics LG - Life's GoodLSU090CE

Device: LG Electronics LG - Life's GoodLSU090CE
Category: Air Conditioner
Manufacturer: LG Electronics
Size: 5.36 MB
Added : 7/31/2014
Number of pages: 83
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for LG Electronics LG - Life's GoodLSU090CE. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with LG Electronics LG - Life's GoodLSU090CE.

For your convenience

If looking through the LG Electronics LG - Life's GoodLSU090CE user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual LG Electronics LG - Life's GoodLSU090CE on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual LG Electronics LG - Life's GoodLSU090CE to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
LG Electronics LG - Life's GoodLSU090CE User manual - Online PDF
Advertisement
« Page 1 of 83 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual LG Electronics LG - Life's GoodLSU090CE but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to LG Electronics LG - Life's GoodLSU090CE. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

website http://www.lgservice.com
LG
LG
Room Air Conditioner
SERVICE MANUAL
MODELS: LSN090CE LSU090CE
LSN120CE LSU120CE
LSN180CE LSU180CE
LSN240CE LSU240CE
LSN090HE LSU090HE
LSN120HE LSU120HE
LSN180HE LSU180HE
LSN240HE LSU240HE
CAUTION
• BEFORE SERVICING THE UNIT, READ THE SAFETY
PRECAUTIONS IN THIS MANUAL.
• ONLY FOR AUTHORIZED SERVICE PERSONNEL.

Summary of the content on the page No. 2

Air Conditioner Service Manual TABLE OF CONTENTS Safety Precautions..........................................................................................................................................3 Dimensions......................................................................................................................................................9 Symbols Used in this Manual........................................................................................................

Summary of the content on the page No. 3

Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to properties only. Meanings of symbols used in this manual are as shown below. Be su

Summary of the content on the page No. 4

Safety Precautions Be cautious when unpacking For installation, always contact Do not install the product on a and installing the product. the dealer or an Authorized defective installation stand. Service Center. • Shape edges could cause injury. • There is risk of fire, electric • It may cause injury, accident, or Be especially careful of the sharp shock, explosion, or injury. damage to the product. edges. Be sure the installation area Install the indoor unit on the Do not handle the pipe by

Summary of the content on the page No. 5

Safety Precautions Do not place a heater or other Do not let the air conditioner run Do not store of use flammable appliances near the power for a long time when the humidi- gas or combustibles near the air cable. ty is very high and a door or a conditioner. window is left open. • There is risk of fire, failure of the • Moisture may condense and wet • There is risk of fire or product fail- product, and/or electric shock. or damage furnishings. ure. Do not use the product in a When flammable g

Summary of the content on the page No. 6

Safety Precautions Ventilate the product from time Unplug the appliance before When the product is not be used to time when operating it togeth- performing cleaning or mainte- for a long time disconnect the er with a stove, etc. nance. power supply plug or turn off the breaker. • There is risk of fire or electrical • There is risk of electric shock. • There is risk of product damage shock. or failure, or unintended opera- tion. Installation Take care to ensure that nobody Do not insert hand

Summary of the content on the page No. 7

Safety Precautions Operation Use two or more people to lift Do not install the product where Do not direct airflow at room and transport the air conditioner it will be exposed to sea wind occupants. (salt spray) directly. • Avoid personal injury. • It may cause corrosion in the • This could damage your health. product. Corrosion, particularly on the condenser and evaporator fins, could cause product mal- function or inefficient operation. Do not use the product for special Do not block the i

Summary of the content on the page No. 8

Dimensions Do not drink the water drained Use a firm stool or ladder when Replace all the batteries in the from the unit. cleaning or maintaining the air remote. conditioner. • Be careful and avoid personal • There is risk of fire or explosion. • It is not sanitary and could cause injury. serious health issues. Disuse Do not recharge or disassemble the batteries. Do If the liquid from the batteries gets onto your skin not dispose of batteries in a fire. or clothes, wash it well with clean wate

Summary of the content on the page No. 9

Dimensions Dimensions Symbols Used in this Manual This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that could cause harm to the air conditioner. This symbol indicates special notes. NOTICE Indoor Unit H D W Installation plate Model 9 Btu Series 9 Btu Series 12 Btu Series (C/O) (H/P) Dimension W mm(inch) 840(33.1) 894(35.2) 894(35.2) H mm(inch) 270(10.6) 295(11.6) 295(11.6) D mm(inch) 153(6.0) 165(6.5) 165(6.5) Service Manual 9

Summary of the content on the page No. 10

Dimensions H D W Installation plate Model 18 Btu Series 24 Btu Series Dimension W mm(inch) 1090(42.9) 1090(42.9) H mm(inch) 300(11.8) 300(11.8) D mm(inch) 178(7.0) 178(7.0) 10 Room Air Conditioner

Summary of the content on the page No. 11

Dimensions Outdoor Unit 1. 9k, 12k L2 W L3 Gas side (3-way valve) Liquid side (2-way valve) MODEL 9k, 12k DIM unit W mm(inch) 770(30.3) H mm(inch) 540(21.3) D mm(inch) 245(9.6) L1 mm(inch) 287(11.3) L2 mm(inch) 64(2.5) L3 mm(inch) 518(20.4) L4 mm(inch) 10(0.4) L5 mm(inch) 100(3.9) Service Manual 11 L1 H D L4 L5

Summary of the content on the page No. 12

Dimensions 2. 18k, 24k W L6 L5 L7 L8 MODEL 18k, 24k DIM W mm(inch) 870(34.3) H mm(inch) 655(25.8) D mm(inch) 320(12.6) L1 mm(inch) 370(14.6) L2 mm(inch) 25(1.0) L3 mm(inch) 630(24.8) L4 mm(inch) 25(1.0) L5 mm(inch) 546(21.5) L6 mm(inch) 162(6.4) L7 mm(inch) 162(6.4) L8 mm(inch) 54(2.1) L9 mm(inch) 74.5(2.9) L10 mm(inch) 79(3.1) 12 Room Air Conditioner H L4 L3 L2 D L10 L9 L1

Summary of the content on the page No. 13

Introduction Introduction Symbols Used In This Manual This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that may cause harm to the air condi- tioner. NOTICE This symbol indicates special notes. Features Air Inlet Air Filter Front Panel Signal Receptor Air Intake Vents Connecting Wires Connecting Wires Air Intake Vents Piping Piping Air Outlet Drain Hose Vents Drain Hose Air Outlet Vents Base Plate Base Plate Service Manual 13

Summary of the content on the page No. 14

Installation Installation Read carefully, and then follow step by step. Installation Parts Installation plate Type "A" screw and plastic anchor Remote Control Holder Type "B" screw Installation Tools Figure Name Figure Name Screw driver Ohmmeter Electric Drill Hexagonal wrench Measuring Tape, Knife Ammeter Hole Core Drill Gas Leak Detector Thermometer, Spanner Level Torque wrench Flaring Tool Set 14 Room Air Conditioner

Summary of the content on the page No. 15

Installation Installation Map NOTICE Installation parts you should purchase. Installation Plate Sleeve Bushing-Sleeve Putty(Gum Type Sealer) Bend the pipe as closely on the wall as possible, but be careful that it doesn't break. Air Discarge Vertical Air deflector Operation Indication Lamps/ Vinyl tape(Wide) Signal Receptor • Apply after carrying out a drainage test. Forced Operation Button • To carry out the drainage test, remove the air filters Saddle and pour water into the heat

Summary of the content on the page No. 16

Confirm The Refrigerant 1. Check the quality label on the indoor and outdoor unit. 2. Make certain that the refrigerant is R-410A. NOTICE THIS PRODUCT CONTAINS R-410A REFRIGERANT 1) Different compressor oil - R-410A(Polyol ester) / R-22(Mineral). - Do not mix the existing mineral oil. - Do not apply used pipe, tools and gauges covered with the existing mineral oil. 2) Absorption of moisture -Compressor’s oil has the high absorption rate of moisture. 3) Composition - R-410A(R32:R125=50:50wt%). NO

Summary of the content on the page No. 17

Select The Best Location 6. Use a stud finder to locate studs to prevent Indoor unit unnecessary damage to the wall. 1. Do not have any heat or steam near the unit. 2. Select a place where there are no obstacles in front of the unit. More than 3. Make sure that condensation drainage can be 12cm(4.7in) More than conveniently routed away. 30cm(11.8in) 4. Do not install near a doorway. More than 30cm(11.8in) 5. Ensure that the space around the left and right More than 8ft(2.4m) of the unit is mor

Summary of the content on the page No. 18

Piping Length And Elevation Standard Max. Max. Pipe Size Capacity Additional Refrigerant Length Elevation length g/m(oz/ft) (Btu/h) Suction Evap m(ft) B m(ft) A m(ft) 9k(C/O) 3/8" 1/4" 7.5(25) 7.5(25) 15(49) 20(0.22) 9k(H/P), 12k 1/2" 1/4" 7.5(25) 7.5(25) 15(49) 20(0.22) 18k(C/O) 1/2" 1/4" 7.5(25) 15(49) 30(98) 20(0.22) 18k(H/P), 24k 5/8" 1/4" 7.5(25) 15(49) 30(98) 30(0.32) Outdoor unit Outdoor unit A Oil trap Indoor unit Indoor unit B B In case more than 5m(16.4ft) • Capacity is based on stand

Summary of the content on the page No. 19

How To Mount Installation Plate The wall you select should be strong and solid enough Installation Plate to prevent vibration 1. Mount the installation plate on the wall with type "A" screws. If mounting the unit on a concrete wall, use anchor bolts. Chassis • Mount the installation plate horizontally by aligning the Hook centerline using a level. Type “A” 2. Measure the wall and mark the centerline. It is also important to use caution concerning the location of the instal- lation plate-routing

Summary of the content on the page No. 20

Flaring Work Main cause for gas leakage is due to defect in flaring work. Carry out correct flaring work in the follow- ing procedure. Cut the pipes and the cable. 1. Use the piping kit accessory or the pipes purchased locally. Copper 2. Measure the distance between the indoor and the out- Slanted Uneven Rough pipe 90° door unit. 3. Cut the pipes a little longer than measured distance. 4. Cut the cable 1.5m(59.1in) longer than the pipe length. Burrs removal Pipe 1. Completely remove all burrs


Alternative user manuals
# User manual Category Download
1 LG Electronics 3828A20025V User manual Air Conditioner 45
2 LG Electronics -BKE 7630 NS G User manual Air Conditioner 18
3 LG Electronics 3828A20025U User manual Air Conditioner 11
4 LG Electronics 230/208V User manual Air Conditioner 23
5 LG Electronics 6710 YS User manual Air Conditioner 28
6 LG Electronics 3828A22005P User manual Air Conditioner 13
7 LG Electronics A3UH363FA0, A3UC363FA0, AMNH093D4A0, AMNC093D4A0, AMNH123DEA0, AMNC123DEA0, AMNH093APM0, AMNC093APM0, AMNH123APM0, AMNC123APM0 User manual Air Conditioner 1
8 LG Electronics 6720 YS User manual Air Conditioner 0
9 LG Electronics User manual Air Conditioner 7
10 LG Electronics A2UH243FA0(LMU240HE) User manual Air Conditioner 2
11 LG Electronics 3828A30087S User manual Air Conditioner 1
12 LG Electronics A2UC243FA0 (LMU240CE) User manual Air Conditioner 0
13 LG Electronics AMNC093APM0(LMAN090CNS) User manual Air Conditioner 0
14 LG Electronics AMNH123APM0(LMAN120HNS) User manual Air Conditioner 0
15 LG Electronics AMNH093APM0(LMAN090HNS) User manual Air Conditioner 0
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21