Whirlpool LI3Z3A user manual

User manual for the device Whirlpool LI3Z3A

Device: Whirlpool LI3Z3A
Category: Ventilation Hood
Manufacturer: Whirlpool
Size: 0.97 MB
Added : 7/13/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Whirlpool LI3Z3A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Whirlpool LI3Z3A.

For your convenience

If looking through the Whirlpool LI3Z3A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Whirlpool LI3Z3A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Whirlpool LI3Z3A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Whirlpool LI3Z3A User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Whirlpool LI3Z3A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Whirlpool LI3Z3A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

30" (76.2 CM) AND 36" (91.4 CM) RANGE HOOD
Installation Instructions and Use & Care Guide
For questions about features, operation/performance, parts, accessories or service, call: 1-800-253-1301
or visit our website at www.whirlpool.com
In Canada, call 1-800-807-6777 or visit our website at www.whirlpool.ca
HOTTE D’ASPIRATION DE
30" (76,2 CM) ET 36" (91,4 CM)
Instructions d’installation et Guide d’utilisation et d’entretien
Au Canada, pour assistance, installation ou service, composer
le 1-80

Summary of the content on the page No. 2

TABLE OF CONTENTS TABLE DES MATIÈRES RANGE HOOD SAFETY .................................................................2 SÉCURITÉ DE LA HOTTE DE CUISINIÈRE ...............................15 INSTALLATION REQUIREMENTS ................................................4 EXIGENCES D'INSTALLATION...................................................17 Tools and Parts ............................................................................4 Outils et pièces.............................................

Summary of the content on the page No. 3

IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ■ Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ■ Use this unit only in the manner intended by the ignite. Heat oils slowly on low or medium settings. manufacturer. If you have questions, contact the manufacturer. ■ Always turn hood ON when c

Summary of the content on the page No. 4

INSTALLATION REQUIREMENTS Tools and Parts Location Requirements Gather the required tools and parts before starting installation. IMPORTANT: Observe all governing codes and ordinances. Read and follow the instructions provided with any tools listed ■ It is the installer’s responsibility to comply with installation here. clearances specified on the model/serial rating plate. The model/serial rating plate is located inside the range hood on Tools needed the left wall. ■ Drill ■ Range hood loca

Summary of the content on the page No. 5

For the most efficient and quiet operation: Installation Clearances ■ Use no more than three 90° elbows. ■ Make sure there is a minimum of 24" (61 cm) of straight vent between the elbows if more than 1 elbow is used. ■ Do not install 2 elbows together. ■ Use clamps or duct tape to seal all joints in the vent system. ■ The vent system must have a damper. ■ Use caulking to seal exterior wall or roof opening around the C cap. Cold Weather Installations B An additional back draft damper should be

Summary of the content on the page No. 6

Calculating Vent System Length Electrical Requirements Observe all governing codes and ordinances. To calculate the length of the system you need, add the Ensure that the electrical installation is adequate and in equivalent feet (meters) for each vent piece used in the system. conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) Vent System Part 1 and C22.2 No. 0-M91 (latest edition) a

Summary of the content on the page No. 7

INSTALLATION INSTRUCTIONS Prepare Location NOTE: It is recommended that the vent system be installed To wire through top: before hood is installed. 1. Mark a line distance “A” from the right of the centerline on the underside of the cabinet. Mark the point on this line that is Before making cutouts, make sure there is proper clearance ⁷⁄₈" (2.2 cm) from back wall. Drill a 1¼" (3.2 cm) diameter hole within the ceiling or wall for exhaust vent. through the cabinet at this point. 1. Disconnec

Summary of the content on the page No. 8

4. Repeat steps 1-3 for the underside of the top of the cabinet. To make a circular vent opening on the underside of the cabinet top: 1. Mark a centerline on the underside of the top of cabinet. 2. Mark a line 5" (12.7 cm) from the back wall on the underside of the top of cabinet. Cabinet cutouts 3. Use a compass or a circle template to draw a circle with a diameter that is ¼" (0.64 cm) larger than the vent. *¹⁄₂" (1.3 cm) 4. Use saber or keyhole saw to cut the circular vent opening. Circular

Summary of the content on the page No. 9

2. Lift the range hood up under cabinet and determine final NOTE: The 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vent location by centering beneath cabinet. Mark on the underside connector can be installed up to 1" (2.5 cm) on either side of the hood center to accommodate off center ductwork. of cabinet the location of the 4 keyhole mounting slots on the range hood. Set range hood aside on a covered surface. B A A C A. Keyhole slot D 3. Use ¹⁄₈" (3 mm) drill bit and drill 4 pilot holes as shown

Summary of the content on the page No. 10

3. Remove the power supply knockout from the top or rear of 2. Use UL listed wire connectors and connect white wires (A) the vent hood (depending on the incoming location of your together. home power supply cable) and install a UL listed or CSA 3. Use UL listed wire connectors and connect black wires (B) approved ¹⁄₂" strain relief. together. A WARNING Fire Hazard Electrically ground the blower. A. Power supply knockout Use copper wire. 4. Using 2 or more people, lift the hood into final posi

Summary of the content on the page No. 11

To avoid damage to the stainless steel, do not use cleaners that contain chlorine. RANGE HOOD USE Cleaning Method: ■ Rub in direction of grain to avoid scratching or damaging the The range hood is designed to remove smoke, cooking vapors surface. and odors from the cooktop area. For best results, start the hood before cooking and allow it to operate several minutes after the ■ For stainless steal models, Stainless Steel Cleaner and Polish cooking is complete to clear all smoke and odors fr

Summary of the content on the page No. 12

WIRING DIAGRAM Light Switch Motor Switch On - Off Low - Off - High SE116B BK BK W Motor Characteristics Ground Power Supply 120 VAC Screw Frequency 60 Hz Amperage 0.9 ±10% A Wattage Rating 50 ±10% Watts Motor Resistance 22.3 ±10% Ohms White - Red 13.4 ±10% Ohms White - Black C19 N GND L 12 W W BK Speed 2 BR W Common W R Speed 1 R BR BK BK R

Summary of the content on the page No. 13

ASSISTANCE OR SERVICE When calling for assistance or service, please know the purchase date and the complete model and serial number of your In Canada appliance. This information will help us to better respond to your Call the Whirlpool Canada LP Customer eXperience Centre toll request. free: 1-800-807-6777. Our consultants provide assistance with: If you need replacement parts If you need to order replacement parts, we recommend that you ■ Features and specifications on our full line of ap

Summary of the content on the page No. 14

WHIRLPOOL CORPORATION MAJOR APPLIANCE WARRANTY LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter “Whirlpool”) will pay for Factory Specified Parts and repair labor to correct defects in materials or workmanship. Service must be provided by a Whirlpool designated service company. This limited warranty is valid o

Summary of the content on the page No. 15

SÉCURITÉ DE LA HOTTE DE CUISINIÈRE Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité. Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d’autres. Tous les messages de sécurité suivront le symbole d’alert

Summary of the content on the page No. 16

IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : POUR MINIMISER LE RISQUE AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIÈRE : D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS ■ Ne jamais laisser un élément de surface fonctionner à SUIVANTES : puissance de chauffage maximale sans surveillance. Un renversement/débordement de matière graisseuse pourrait ■ Utiliser cet appareil uniquement dans les applications provoquer une infla

Summary of the content on the page No. 17

EXIGENCES D'INSTALLATION Outils et pièces Exigences d'emplacement Rassembler les outils et pièces nécessaires avant d’entreprendre IMPORTANT : Observer les dispositions de tous les codes et l’installation. Lire et observer les instructions fournies avec règlements en vigueur. chacun des outils de la liste ci-dessous. ■ C’est à l’installateur qu’incombe la responsabilité de respecter les distances de séparation exigées, spécifiées sur Outils nécessaires la plaque signalétique de l’appareil. La

Summary of the content on the page No. 18

■ Ne pas installer 2 coudes successifs. Distances de dégagement à respecter ■ Au niveau de chaque jointure du circuit d'évacuation, assurer l'étanchéité avec les brides de serrage ou du ruban adhésif. ■ Le circuit d’évacuation doit comporter un clapet anti-reflux. ■ À l’aide d’un produit de calfeutrage, assurer l’étanchéité autour de la bouche de décharge à l’extérieur (à travers le mur ou le toit). Installations dans les régions au climat froid C On doit installer un clapet anti-reflux suppl

Summary of the content on the page No. 19

Calcul de la longueur du circuit d’évacuation Spécifications électriques Observer les dispositions de tous les codes et règlements en Pour calculer la longueur effective du circuit d’évacuation vigueur. nécessaire, additionner les longueurs équivalentes (en pieds ou Vérifier que l'installation électrique a été correctement effectuée mètres) de tous les composants utilisés dans le système. et qu'elle est conforme aux spécifications de la plus récente édition des normes National Electrical

Summary of the content on the page No. 20

INSTRUCTIONS D’INSTALLATION Préparation de l'emplacement REMARQUE : Il est recommandé d'installer le système Câblage à travers le sommet du placard : d'évacuation avant de procéder à l'installation de la hotte. 1. Tracer une ligne de distance “A” à partir de la droite de l’axe central, sur la face inférieure du placard. Sur cette ligne, Avant d’exécuter les découpages, vérifier la disponibilité d’un marquer le point situé à ⁷⁄₈" (2,2 cm) du mur arrière. Percer en dégagement suffisant dans


Alternative user manuals
# User manual Category Download
1 Whirlpool 30 User manual Ventilation Hood 26
2 Whirlpool 35-718 User manual Ventilation Hood 7
3 Whirlpool 29-718 User manual Ventilation Hood 0
4 Whirlpool 4.32E+13 User manual Ventilation Hood 2
5 Whirlpool 24" (58 CM) User manual Ventilation Hood 3
6 Whirlpool 36" User manual Ventilation Hood 1
7 Whirlpool 9763375 User manual Ventilation Hood 1
8 Whirlpool 99044504A User manual Ventilation Hood 0
9 Whirlpool 48" User manual Ventilation Hood 2
10 Whirlpool 99044505A User manual Ventilation Hood 0
11 Whirlpool 761883306 User manual Ventilation Hood 0
12 Whirlpool 9760266 User manual Ventilation Hood 0
13 Whirlpool GZ5730 User manual Ventilation Hood 0
14 Whirlpool GZ5730XRB1 User manual Ventilation Hood 0
15 Whirlpool GZ5730XR User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0